{\rtf1\ansi\deff0\uc1\ansicpg1252\deftab720{\fonttbl{\f0\fnil\fcharset1 Arial;}{\f1\fnil\fcharset1 Times New Roman;}{\f2\fnil\fcharset1 sans-serif;}{\f3\fnil\fcharset1 Futura Lt BT;}{\f4\fnil\fcharset1 Tahoma;}{\f5\fnil\fcharset2 Symbol;}{\f6\fnil\fcharset2 Symbol;}{\f7\fnil\fcharset2 Wingdings;}{\f8\fnil\fcharset2 Wingdings;}{\f9\fnil\fcharset1 Calibri;}{\f10\fnil\fcharset1 Courier New;}{\f11\fnil\fcharset1 Gothic720 Lt BT;}}{\colortbl\red0\green0\blue0;\red255\green0\blue0;\red0\green128\blue0;\red0\green0\blue255;\red255\green255\blue0;\red255\green0\blue255;\red128\green0\blue128;\red128\green0\blue0;\red0\green255\blue0;\red0\green255\blue255;\red0\green128\blue128;\red0\green0\blue128;\red255\green255\blue255;\red192\green192\blue192;\red128\green128\blue128;\red0\green0\blue0;\red191\green191\blue191;\red80\green80\blue80;\red128\green128\blue0;\red33\green33\blue33;\red86\green86\blue86;\red0\green84\blue147;\red54\green95\blue145;\red36\green63\blue96;\red39\green39\blue39;\red46\green83\blue149;}\wpprheadfoot1\paperw11906\paperh16838\margl1134\margr567\margt1928\margb1134\headery1134\footery1134\endnhere\sectdefaultcl{\*\generator WPTools_7.270;}{\info{\*\title Das Dokument umfasst MM_Seitenzahl Seiten}
{\*\author Torsten Kiehns}
{\*\operator AVAPLAN :: T. Kiehns}
{\*\company k}
}{\*\listtable{\list\listtemplateid1
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li720\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6\cf15}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li1440\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10\cf15}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li2160\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8\cf15}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li2880\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6\cf15}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li3600\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10\cf15}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li4320\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8\cf15}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li5040\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6\cf15}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li5760\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10\cf15}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelnfc23\fi-360\li6480\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8\cf15}
\listid1}{\list\listtemplateid2
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid2}{\list\listtemplateid3
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid3}{\list\listtemplateid4
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid4}{\list\listtemplateid5
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid5}{\list\listtemplateid6
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid6}{\list\listtemplateid7
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid7}{\list\listtemplateid8
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid8}{\list\listtemplateid9
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid9}{\list\listtemplateid10
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid10}{\list\listtemplateid11
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid11}{\list\listtemplateid12
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid12}{\list\listtemplateid13
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid13}{\list\listtemplateid14
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid14}{\list\listtemplateid15
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid15}{\list\listtemplateid16
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid16}{\list\listtemplateid17
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'01.;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid17}{\list\listtemplateid18
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'02\'00.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid18}{\list\listtemplateid19
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc1\levelstartat1{\leveltext\'02\'00.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc3\levelstartat1{\leveltext\'02\'01.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'02.;}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'02\'03);}{\levelnumbers \'01;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc2\levelstartat1{\leveltext\'03(\'04);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc4\levelstartat1{\leveltext\'03(\'05);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'06);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'07);}{\levelnumbers \'02;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'03(\'08);}{\levelnumbers \'02;}}
\listid19}{\list\listtemplateid20
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li720\levelstartat1{\leveltext\'01-;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li1440\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li2160\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li2880\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li3600\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li4320\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li5040\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li5760\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li6480\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
\listid20}{\list\listtemplateid21
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li720\levelstartat1{\leveltext\'01-;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li1440\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li2160\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li2880\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li3600\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li4320\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li5040\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li5760\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li6480\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
\listid21}{\list\listtemplateid22
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li720\levelstartat1{\leveltext\'01-;}{\levelnumbers ;}}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li1440\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li2160\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li2880\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li3600\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li4320\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li5040\levelstartat1{\leveltext\'01\u61623 ?;}{\levelnumbers ;}\f6}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li5760\levelstartat1{\leveltext\'01o;}{\levelnumbers ;}\f10}
{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent0\levelspace0\levelnfc23\fi-360\li6480\levelstartat1{\leveltext\'01\u61607 ?;}{\levelnumbers ;}\f8}
\listid22}{\list\listtemplateid23\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid23}{\list\listtemplateid24\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid24}{\list\listtemplateid25\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid25}{\list\listtemplateid26\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid26}{\list\listtemplateid27\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid27}{\list\listtemplateid28\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid28}{\list\listtemplateid29\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid29}{\list\listtemplateid30\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid30}{\list\listtemplateid31\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid31}{\list\listtemplateid32\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid32}{\list\listtemplateid33\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid33}{\list\listtemplateid34\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid34}{\list\listtemplateid35\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid35}{\list\listtemplateid36\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid36}{\list\listtemplateid37\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid37}{\list\listtemplateid38\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid38}{\list\listtemplateid39\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid39}{\list\listtemplateid40\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid40}{\list\listtemplateid41\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid41}{\list\listtemplateid42\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid42}{\list\listtemplateid43\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid43}{\list\listtemplateid44\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid44}{\list\listtemplateid45\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid45}{\list\listtemplateid46\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid46}{\list\listtemplateid47\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid47}{\list\listtemplateid48\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid48}{\list\listtemplateid49\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid49}{\list\listtemplateid50\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid50}{\list\listtemplateid51\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid51}{\list\listtemplateid52\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid52}{\list\listtemplateid53\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid53}{\list\listtemplateid54\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid54}{\list\listtemplateid55\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid55}{\list\listtemplateid56\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid56}{\list\listtemplateid57\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid57}{\list\listtemplateid58\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid58}{\list\listtemplateid59\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid59}{\list\listtemplateid60\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid60}{\list\listtemplateid61\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid61}{\list\listtemplateid62\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid62}{\list\listtemplateid63\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid63}{\list\listtemplateid64\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid64}{\list\listtemplateid65\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid65}{\list\listtemplateid66\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid66}{\list\listtemplateid67\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid67}{\list\listtemplateid68\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid68}{\list\listtemplateid69\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'01;}{\levelnumbers ;}\f6}\listid69}{\list\listtemplateid70\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid70}{\list\listtemplateid71\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid71}{\list\listtemplateid72\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid72}{\list\listtemplateid73\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid73}{\list\listtemplateid74\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid74}{\list\listtemplateid75\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid75}{\list\listtemplateid76\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid76}{\list\listtemplateid77\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid77}{\list\listtemplateid78\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid78}{\list\listtemplateid79\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid79}{\list\listtemplateid80\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid80}{\list\listtemplateid81\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid81}{\list\listtemplateid82\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc23\levelstartat1{\leveltext\'02\'00;}{\levelnumbers \'02;}\f6}\listid82}{\list\listtemplateid83\listsimple{\listlevel\leveljc0\levelfollow0\levelstartat1\levelindent360\levelnfc0\levelstartat1{\leveltext\'02\'00);}{\levelnumbers \'01;}}\listid83}}{\*\listoverridetable{\listoverride\listid1\listoverridecount0\ls1}{\listoverride\listid2\listoverridecount0\ls2}{\listoverride\listid3\listoverridecount0\ls3}{\listoverride\listid4\listoverridecount0\ls4}{\listoverride\listid5\listoverridecount0\ls5}{\listoverride\listid6\listoverridecount0\ls6}{\listoverride\listid7\listoverridecount0\ls7}{\listoverride\listid8\listoverridecount0\ls8}{\listoverride\listid9\listoverridecount0\ls9}{\listoverride\listid10\listoverridecount0\ls10}{\listoverride\listid11\listoverridecount0\ls11}{\listoverride\listid12\listoverridecount0\ls12}{\listoverride\listid13\listoverridecount0\ls13}{\listoverride\listid14\listoverridecount0\ls14}{\listoverride\listid15\listoverridecount0\ls15}{\listoverride\listid16\listoverridecount0\ls16}{\listoverride\listid17\listoverridecount0\ls17}{\listoverride\listid18\listoverridecount0\ls18}{\listoverride\listid19\listoverridecount0\ls19}{\listoverride\listid20\listoverridecount0\ls20}{\listoverride\listid21\listoverridecount0\ls21}{\listoverride\listid22\listoverridecount0\ls22}{\listoverride\listid23\listoverridecount0\ls23}{\listoverride\listid24\listoverridecount0\ls24}{\listoverride\listid25\listoverridecount0\ls25}{\listoverride\listid26\listoverridecount0\ls26}{\listoverride\listid27\listoverridecount0\ls27}{\listoverride\listid28\listoverridecount0\ls28}{\listoverride\listid29\listoverridecount0\ls29}{\listoverride\listid30\listoverridecount0\ls30}{\listoverride\listid31\listoverridecount0\ls31}{\listoverride\listid32\listoverridecount0\ls32}{\listoverride\listid33\listoverridecount0\ls33}{\listoverride\listid34\listoverridecount0\ls34}{\listoverride\listid35\listoverridecount0\ls35}{\listoverride\listid36\listoverridecount0\ls36}{\listoverride\listid37\listoverridecount0\ls37}{\listoverride\listid38\listoverridecount0\ls38}{\listoverride\listid39\listoverridecount0\ls39}{\listoverride\listid40\listoverridecount0\ls40}{\listoverride\listid41\listoverridecount0\ls41}{\listoverride\listid42\listoverridecount0\ls42}{\listoverride\listid43\listoverridecount0\ls43}{\listoverride\listid44\listoverridecount0\ls44}{\listoverride\listid45\listoverridecount0\ls45}{\listoverride\listid46\listoverridecount0\ls46}{\listoverride\listid47\listoverridecount0\ls47}{\listoverride\listid48\listoverridecount0\ls48}{\listoverride\listid49\listoverridecount0\ls49}{\listoverride\listid50\listoverridecount0\ls50}{\listoverride\listid51\listoverridecount0\ls51}{\listoverride\listid52\listoverridecount0\ls52}{\listoverride\listid53\listoverridecount0\ls53}{\listoverride\listid54\listoverridecount0\ls54}{\listoverride\listid55\listoverridecount0\ls55}{\listoverride\listid56\listoverridecount0\ls56}{\listoverride\listid57\listoverridecount0\ls57}{\listoverride\listid58\listoverridecount0\ls58}{\listoverride\listid59\listoverridecount0\ls59}{\listoverride\listid60\listoverridecount0\ls60}{\listoverride\listid61\listoverridecount0\ls61}{\listoverride\listid62\listoverridecount0\ls62}{\listoverride\listid63\listoverridecount0\ls63}{\listoverride\listid64\listoverridecount0\ls64}{\listoverride\listid65\listoverridecount0\ls65}{\listoverride\listid66\listoverridecount0\ls66}{\listoverride\listid67\listoverridecount0\ls67}{\listoverride\listid68\listoverridecount0\ls68}{\listoverride\listid69\listoverridecount0\ls69}{\listoverride\listid70\listoverridecount0\ls70}{\listoverride\listid71\listoverridecount0\ls71}{\listoverride\listid72\listoverridecount0\ls72}{\listoverride\listid73\listoverridecount0\ls73}{\listoverride\listid74\listoverridecount0\ls74}{\listoverride\listid75\listoverridecount0\ls75}{\listoverride\listid76\listoverridecount0\ls76}{\listoverride\listid77\listoverridecount0\ls77}{\listoverride\listid78\listoverridecount0\ls78}{\listoverride\listid79\listoverridecount0\ls79}{\listoverride\listid80\listoverridecount0\ls80}{\listoverride\listid81\listoverridecount0\ls81}{\listoverride\listid82\listoverridecount0\ls82}{\listoverride\listid83\listoverridecount0\ls83}}{\stylesheet
{\s1\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 NONE;}
{\s2\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20\b BOLD;}
{\s3\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20\b\i BOLDITALIC;}
{\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs16\b BOLD8;}
{\s5\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs16 Arial8;}
{\s6\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs16\cf1 Arial8Red;}
{\s7\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs16\cf2 Arial8Green;}
{\s8\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs20\b BOLD10;}
{\s9\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs20\b SummeE0;}
{\s10\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs20\b SummeE1;}
{\s11\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs20 SummeE2;}
{\s12\li0\fi0\ri0\sb0\sa800\ql\vertalt\fs20 TOC;}
{\s13\li0\fi0\ri0\sb0\sa0\qc\vertalt\fs20\b DB_LV;}
{\s14\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs16 body;}
{\s15\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs20 p;}
{\s16\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 .dummy;}
{\s17\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 .dummy2;}
{\s18\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs16 .me_cell;}
{\s19\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs18\b .f9bold;}
{\s20\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs18 .f9;}
{\s21\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs14 .f7;}
{\s22\li0\fi0\ri0\sb0\sa0\ql\vertalt\f1\fs24 .fSumSign;}
{\s23\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20\cf17 .fgrau;}
{\s24\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 .tableBorder;}
{\s25\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 .border;}
{\s26\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 .borderR;}
{\s27\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 .borderB;}
{\s28\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 .borderBR;}
{\s29\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs20\b .folder;}
{\s30\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs20 .pos;}
{\s31\li0\fi0\ri0\sb0\sa0\qr\vertalt\fs20 .menge;}
{\s32\li0\fi0\ri0\sb0\sa0\qr\vertalt\fs20 .currency;}
{\s33\li0\fi0\ri0\sb0\sa0\ql\vertalt\f0\fs16\snext33 AVAPLAN_LVCover_Ort_Datum;}
{\s34\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs24 AVAPLAN_LVCover_Ort_Datum_Linie;}
{\s35\li0\fi0\ri0\sb0\sa0\ql\vertalt\f9\fs20\i\snext35 footer;}
{\s36\li0\fi0\ri0\sb0\sa0\ql\vertalt\f2\fs18 .Cell;}
{\s37\li0\fi0\ri0\sb0\sa0\qr\vertalt\f2\fs18 Cell.RightAligned;}
{\s38\li0\fi0\ri0\sb0\sa160\sl259\slmult1\ql\vertalt\f9\fs22 Normal;}
{\s39\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20 Default Paragraph Font;}
{\s40\li0\fi0\ri0\sb0\sa0\ql\vertalt\f9\fs20\i\snext40 header;}
{\s41\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20\i\sbasedon39 Kopfzeile Zchn;}
{\s42\li0\fi0\ri0\sb0\sa0\ql\vertalt\fs20\i Fuzeile Zchn;}
{\s43\li720\fi0\ri0\sb0\sa0\ql\vertalt\fs24 List Paragraph;}
{\s44\li0\fi0\ri0\sb0\sa0\ql\vertalt\f11\fs24\cf15 Default;}
{\s45\li0\fi0\ri0\sb0\sa0\slmult0\sl241\ql\vertalt\fs20 Pa1;}
{\s46\li0\fi0\ri0\sb0\sa0\slmult0\sl201\ql\vertalt\f11\fs20\cf15 A7;}}
{{\footer{\pard\plain\s35\li0\fi0\ri0\sb0\sa0\tqr\tx9406\ql\vertalt\wpparflg32\f0\fs20\i Das Dokument umfasst {\field{\*\fldinst{NUMPAGES \\* MERGEFORMAT }}{\*\fldrslt{217}}} Seiten\tab LV-Datum: \par
}}
\pard\plain\brdrt\brdrs\brdrw10\brsp80\s0\sl360\slmult1\qc\wpparflg32\plain\f1\fs22{\shp{\*\shpinst\shpleft1134\shptop1134\shpright3969\shpbottom1871\shpbxpage\shpbypage{\sp{\sn shapeType}{\sv 75}}{\sp{\sn pib}{\sv{\shpwr2\shpwrk3\pict\jpegblip\picw5385\pich1395\picwgoal2835\pichgoal737
\bin17286  JFIF  ` `   XExif  MM *    1       >Q       Q        Q            Adobe ImageReady   C 		



	 C  ]g"            	
    } !1AQa"q2#BR$3br	
%&'()*456789:CDEFGHIJSTUVWXYZcdefghijstuvwxyz        	
   w !1AQaq"2B	#3Rbr
$4%&'()*56789:CDEFGHIJSTUVWXYZcdefghijstuvwxyz   ? 2ַqs$jlıK:S=bO:mjFX' 5sJ#}>SeOJ>+|Ck=AI'IP!~ Po#pE+|V,Ro&h[d
 ;Ů4j"<MG" Y:ZϟEVrm_R*IC0|7P:Fs8#ºڭ&|Ҩ @ܜjGNQVӫtԩ5+m//7_Z?svZXR-V[<#dܣQҾ{ jZċ!xBuVu_uKoIoHueXGby ÏZǍ z9TݭV5gp '9>/VT$[m+ߕ7{~mf|ƭ(ԛ\QI[kh~3_km6K'ߒO)w1-krKK(T@@ W%'.y`Ə⮙Ŗ >!AooGqR5 & 
~- R % ?[e a(zk𪸚{ `2܇,xJM1켏IqIKbc\{G<q5ki0̂8AԒ :@& D=  k_?]rwƖM<~kj|T1GUHPbC!9iwn~!ʢ *QLl8_;Մz&1jV5Q)c!E|3#zK I9IXQ
  mBu?	|wPܶɀ(ɴx]̻05y.mm#WF5UNmͧ&1cNj7\>t^<}M.dCk=b?o7;Νa$:v OKkXºJ ?;>" '^>׼<w+7JnU# ^O+?O&5?ísj:|]^Jevf< '
 iڃO+T]?O!E.o s UhUܚ'Z(u	g-#* C u/cq0$$[i^MO<\}~eK-ӌK%v??qn2cRu$IrpVr^VOK~Կ]ߊ5+?>xXƥ2g!	%R:nnG;- 5%I	'5%QHng' M~Ao|^Ğ(!Ic{k,$.pͿfA 77a9V۶vKD_ggӜѧͤc)Uw&ܥmRG߇)xWkq^'SX\b}/7 h7|ԭ5XΘ}#ޅ鯿 h!>_Y^xK6^uh)ܡR:3Ls x_^k-kBNFNFSAxaKݽGGAaVSI^2vnK}Ṥ=WOCax1đE
(ig__ƾkmSG9BOy?QQHA? 4 7MXG{
,>hoF܍S_qùשU㿚gǃe	Y%}Uzwj >&xS|u^"^HpUG@ y6ſ*_  G~-y x~oUXIOypG#JXx6SG	 $?ڣZ<qsٚ:=A131>	qUuxAoݏ#'i 3!iם⏇4]CsfI9F	<!_]}U ?҃48/juTRJѷwxg
o /xh_GiZbiۿeݷsc9_? |F  Wߟro> =cWxK^s*2iic<_kQی[գ4~_NR/|7g54ӻD	gv$ԓ^^/  K bZ;oWW%V¿௟Px<?x@ #T//]dF!?7*~dk[M"7!?x+1#jxt/6S.$.ŞypIqe(FJOWn #gqU<IAJ5̓\'9kTv? |F  W_C?Ě|;ϊu[ϣͫj=
#HĪyР,k7[?kX};yr8ao<{E.^èYˌ' dwʾozhx ѥM{h{c(I4Muu(7yզ~џ</;B1$,ʿfR3uOT8-l-yq4MX+Y'H/$UI 9ɯ_X6WV@1R`;H̪H]H$ Λw÷muKouV+lVWgd JqեUpn/՟̰>#<jkJv睬c|I/k V>%xC3ml.mO.@5Z5-r{_^J%睤b~3	/W63GoIeuxmE@eo/iqG_xW~io6?h
b}簙>cGjy= 6~Ğ'7VqjE+ӣN7{s[)f_syזz)#4įXDK=ǬRC~yd#k?@:ų-8da򽾫?I"a]\Ξ_>7 6IE =I}|>-cQ_k݃Myq
YFp x(lc3tJÐ57aDҩƄ#WI_ڟ|E_	[5V$ʤ\Aɸ$M$/oFz}4++&D-lc|`* b͚EVkᐭ#wzs0gXX2BAn?oUo-G@':._KFNEnz\8p&_v w_ll|UuecVvCA#)rj*?mzxVX>[h8`W3C:O]1YuUff@U$p~ʰ_W0*+.36}bkNKg6xt'M($ScV$bI'$rkG/s:4~nc7E=pF5xb cª@<2I_EgXKGetRZu ˓2@3
UhӦn뒭RZ9,[I_KVS?jjZ)e*02p>k'#r?`:~kZ6iwgһov /^ C+]Wo-2 =ro??oN4yHY-4kq'O|Ex%ֽ\319,J1uuDvM681(gŚN)I۹mdSYG/gAt?Oս+I߲m?y|68!tchǝpyOO+;v5!Eer+si__|?ȳYm9bYaYDc*eoMo#q,[F-9Jnd;JvtQE~ (ï;▩k#Gq588d7>>) H) }TKZ+^"NX+͸TN_ ?c$?mm %nwn_20ʿّ@#C#j$ _4dm'G\
ਯMƥGĘJoT^(~!{<	?o#-Jb7Ⱦe?ͺ~,"W4HY
A(U{p2)kx[</JNZ{:5/ $|-__o	U_i0-<,RGS~K|MJSTTOI,?
NrYgn)pLMZn>k Ir?5?~?f ц`&:RռxeFXƴ~?f ц=> ٧BW-s? ۏ(ǁ(E L Km ixJ]}:y:YI&zce?I7u[X5IyS*][C k_8L  [Iݪx-Q~it_sS7 v1+oO揧oџ;.TJꦕfڑuB !wʿ/kkg^)j߼b󜜷
wI=+=Cj{IE =Or<NMx|REڵK5%i.EN1+ 襯h t Ɉ% ^ E-v Ɲ/u'?7a%&pEq_ga!9hSqj'Xl<\:RݷQnwS{E[ܖ<[PE#+:^7 h ̗_UGw0{g	p_7|ES׉jڅyerd  _~QM#?5[˩#hbyQrIds
Xb.}W?zdK8~
xeɺSD[m2n$nʿ,wܟY`\ ;9=kZy/X/>rMP$}3Mc:0d2:0GufkZ<l+eѫ>z~]tr"VsS_nܩ[S~?|!.>{Lv lU.\1@Oj>[~?|wy;|
'=Ι5 x?Ś|%MwVi}b_q9	|Pvq"Yږ-]U#e?	r͹v?*+OrQsh ~$VtoSͼیQHk^S_利)o 3hS`cJ^
- 1c7ww|.Nŏrj;WW =~!Q>֒$ 奔O5bQI½h,55OnUo (¦&}2թ}  j &?v:~&ӖƉm<=q $[  =y	O~*^l!<ܗv-!{#nߒ.F22{ĵafzx8βjhV,Tjv$jYI7v?c b-_~{7û=
x]Me&i»bcv{bc )*w ˪+__LD]]cBpQÜGGTF3kR&''R۟ Out=

M3GmDT_3$Xcڹ?>%OfG-J{:8cIsTOxWu&m\]Zd٬o.֭%ᅤXPJ0$42ʜy[#1j˖S7yYx66:m̖+i#Ws1$I5c u]oVP~׋*tosZ^.7>0յoj֚s{4&%b6Q#Ҳov5?mG`3]sԷar+Fyn~(Δ۪UJz?/VҨDp=I<@=yz8 zh, 1Uݴhv>$dZyixgT}oz}슩%sRπO EkVKpM?[e a(zkw|n ҇VVo/G D=  k_XٚwEyGV0_Vy'.v7
~s-  k^mk>Mocq갠k.Çw+x>( 4|!!bo
դԒ۸%G_K_,;ޚ̺FmM:&b;ƤA۴~X ?c~h7"m>r~$
x#*ehY-ku# >xwUBj8I^2KG+I6kR] _6K աg9JEt`̓R>\斊Xk{ԕ_: Ds
="ޜ#fּ'D|7m[I7un4]rǽ	\bshľ#d<;|Q#(blی~6;nO ouk].PE%F	%Tx3|LOM{^<eq=Snm|2j3iti+y=~!,|" ieWRޣonHdYbWwU/>Bw`e_ir7C4yʲ*JOstOkTlU_e%_GLn[zI7S'ke%z4;¼&ĨN	TS+6M]]]5-5w+x\tXeyLc
ɯj3~>x^ٛqE=	X# s\_xϿ.%iV$ |;׾)E֍ڵ3gx곜cN1{n2Ul}lG8ͥ	ݤvoZ3MӮ5Fka3UTrX ME_W߲,cTLfx+@{-|  :M_$|Q[/h4Z3fWgS>rZhMuiIY.3lVdFNSg;4_X7m&& (ů?aO_>6iPc
:ۿoX  F `?< f9 1  ?	xzomVI,尼MQRy~˿<	ny?z3.ߵ۶&Fm+P_8GL &7^)Z&c=O2o˯ݿx#^OU_ {4QE~\Q  K bZäxgq/qkYdՄ<.#޾]x	].to[^\HpCsWOMP h?Ro<&pC"T\۞7f,B?W?+W"7QΤ% nɨ8}#I׵[[8d idbTRH}e 8?S{i * ur;JJ?>]=3#zWy<=ô%Zi^[oџxe,&9Kԭ(6}?
g
Om?yMIE DK_X/"CLlvާ4߲5gm=.x\hu&Hs!^;xw'$ֶ'VuTRJ3qWs[NZ?u>_@ڟ|;Ԯ|cٴ4t̘yry{*Cҿݿߵ~ߵׅQq;CKr>[ +? n`F~x' oVCؿe۷HwH\Ept8ڋc^*F|ťy|[n>NU?WsI{xq6 KfNr\azIգ^XJ𓾝]_r(f5U<]EITt{+)Gwnetݺ&;ZZ|=.>qcuL@5btlBASߪ  ~'iZL.ZXD{	U$z_ϝ˖.+O+J=Ϧ s12
N֓(՛s
P|4 ֕BNj`vݵ[wm8Uf<pMͳI*ӊVVտ;fWS,VU:i6ӧT?%_  uEj|AãjhmiJj动M\2?'Ҫ'9v;t~Үaz0/q#i1$䜕OmUXWQJ?&[g,=*Ê^#~s[f.g;,ǥCmse>^pGJ騣5}^ʾa4wi6wW,3'S<&t ⺊(&VRva,=&6V%5XUQt S6<0?_Musô',v9,ǒI$z?5 j רQX}V/,+,UO_2;Kx5(""* vEqo弐KQr Ҽk N$>xFKNdYI!-O潢ʭ
uUEK\r`+ΔR Fٮ7;qjxc	;;Jf[_/H"YNGS(IX:	x7Gi:n Kh# u*(ԒVGT:sm[z;Hދ&iznM.!8*^%/of9"IWX$@?_BQXѫX)z 35oFNP Z>pt&~#.oo.Wf_ҽ/
 ~_^2+UlzQyTpt);҂K48̣ɘ]Rs_3aEWAw?O5SViSSswwZ=ć셙rNh Z垩3ivky]P`yJ+ҽUof|9mksֽnT|M}7ƺ֓i:}=UсVU+fVg
֩<_MY ?~ %k ՟ PG܏cdͿ*/0>n?Ih?g|Ef  K 	?7^E\SG>8к^qwvwg9O<vo?U._Ik\cQ&(cdrb1UZrݶޡEUcqY~|7Ixn̖'I!25 j רQ\ UGlUO_Ai.oggV,0CH@
    v9+&x.GB5 	Ԯ$Ě<v\1뉺 T~7K,4gMtR #0]ᠩᱵHԚ_r<M ]ϺTUf <v"~
|-;d	B0xx;^\N2Mm(8Uv@(]'( ( ( ( ~,VBH|Mo5YlHrȫ_KRkVqß2;1̀_?"Y;2\<1!`bTn>c֝>!|L5xd];Osʒr9BJz	sd8J^:5մ䏏.(ڣ^7͟ixoŚ_߶hY('I7)#"⧅zω4&`kvG"9â
NMaj~|Gh}pqr̎d2I$~i-ͣosbJȔZi/k]hN瓒io{$vtF2Iw=ͼ**x A	y~Wǉ˛Wmzy1*F~i$?*ɮ'>.5?'ǐ#I hlLK omlmn گmY琢aN  =,GRkKyPC7NOwk?J<+qM&i:v,cyƪX׈b/Ջb5Zw|۳_;% C|>Nԣy-}p92d23O=+~xo\,Əǌ;tdMd*b@`=kU')Es-[jK=gU(ӧ\oWf:6ݑ_0 E<x#^v.i	}qvey%
ָMֽjo_ah7FgV Cdwgx<gF>kNGҰ:m3ʽ;>^Q>_u`/cH {~ ADkZNŖoo#7qݍ˜t=ko]?w<<ouu({o[`d%]M1WǊ|7Uo5+&ś&41T|rN&c~FcF5Z禢՛iI-]>?|kIJ1݌EyKF xK^lbp^[8^
"~^g R eYL%SQ4\6'xvvi5o	>j+\cy%dXxcLRIfXbO1 ~5cE 'xs멭tAyv^[MT NqG.+	*n4~FU)1ʉs?(y&^f'՗<)x7WOhڙTj/^&c=3zw1IV'mI6'g(W2Fy>xow|6O.%YIwT\JCp1]I ]pz
:NjN*E9c[IF4􌝾OF}'><Eh#E77̛A%OI$xvPk,zS_D.%2cݸr09?@< ] I?g?
IzErI%܍98V~`:IԨԪ9%d~kCN4i]zm꺽My}uoginyq=Y aOG*rMu:?gi0N'o~s|-䖺^R{Y$co=@G Jfo
|[xf=$+!Y\`W n9ȨTTcZRݬI'm]~̬wWJ4I+m]Y[eU}]7JΧuX:mێsU
BRɡZNlcy k$;ևͮhv\j:TN%ژb@R޸ٯ>y\<naYD& 0^L$mshvu~mwM$i[>OQ|ͦ`⟆<=Kp
wEV`{ޯ~!|&Ծ|MUώ>8/$WWcd݆$P:uX5%k-ߧ3KNgWʜ/wwMQI]YG*B8^IUȴhR`*mGpǆM}o	_
Y$6n\(%HC8?|_~.ԣ4[,%7.dJ3n'p'8#(tRNQEhޟ\gۊ27?GZ]}/Z4{[\[]GsqsjԵ99CAk_ycAM&Gp|pcD)۳1 c.捤5Շ"$v$|X	9ȩқ>G~ *TJc*|v;E_μ4Q5F,Y	-ٻvqi>ӖZ4"Ѥ,)or	
 _/
_xxoQ%!ǩ#0o3<a/9[{~~m2g=]FckyR798kUWT:4"M>i}>ŝqZfԘwzn^? צٴ"@#Opzj []Z}dGkL|A8?BM&I2ɏ/G)6ӖCܥW׽	0iF2vVm+[ͳPςc<E7W@=0'I{[m)鷺8\4Dnqss_?,;:ZύǚơtG4[I'ԕ%EO
x^1߲-_|AuԺYlfKy*HOzwӡ4\SI>gow[w+ĵ1M\RjͶUץ}3|JEMI;F) %xo39V {񾉧Q/HYVdy2L$yYBn\}SbT6K-~}EW{EPEPEP߲(?xW A'/#w|nwAҗ7 
GG<A 	D/26ｎzT1U񤥢-ikt<YNPq]o~<wGÏ6nuk~OJW۸bSO+_kwPCu;/6kx0vW X +USSOEEF|^Cj)[kWWT;#k{2bU%^bV_00`sn7kw oZֿg&s޽:Fm'~f-V|_er<Om߇#v7<37gy,c~T?t|r+ y//%d#VEt=W>oV=VqєޑkOYˇ`e׽wExrEa̐՘$I/eEn|8k-9d>%1dgM9+BRsգx;i٦cc	ooڶj^|h,қdk+HB>T<}I~ZW7L{4YV&xa,*T)BRzFP}JuQX|:-/[G9Tէj-kt>f_]h{b U]]cvEEe\] K- K? _)&<_n<|ڽjc]HUsiͿOnr
:JN^]_ڳ[ Ӵ[?y%wؾ
111X?e'~y>ie1
U#r0Apy ,MSTog~]ߦl	Uu!inm^uV>a_hQ_KYrP {8oݨ9'lJd nb e\yoq\׫Q[;pqi}[G!RZmoo Cu?_hϻ.^?fOho h?Mn#d뎹Mz<O_n:-ߦ6*{Nx %-^;uV>t|*͏]k-_NIPj3gjO㟙>6}C=|F!XK{Crw3o1 ڞkXIkyoowk0Đ7pT	xGR['mi A?*!c5&I5gXxyZSRI6Ӻ~M%˖VRԼ?xzm{h42ˑ20CO,/^.ֽ㋭O;Nzo&A!8 4W
n'hZ_{;]_ɞ\Ӆk|/F~$x\Yۙ$R&2qqzmѕi|f_$VZ셤G&7RYD;Ҽ*0 \$L? n}\=<c+y7t;WQZK4I5)R|Kg᷑r$Zqk3~~̟~ͺϵiAw/gs=7V.i֟KZKֿa'~B <׸QUjzsĺm/|\4QZ	ËZֹȊHv+m8eIk[[[Z4߇ɋi?$7 161c<{{i>ekms<=4W[~x>-'Ckǧ _/UFN2v'^K8Ɠ~5񖥨(40pą]F3uҽʊ㧘W	ӄĬ4XNIZn>s`)4_ 2Mgh	),gh9m^+<5 kԵ5{ui&FRrbv2rI&"ڶq
V{+ݮs
9.
nW= :9 j ln7(۷{t=B:]-[ ;zt)F%hY//}}}}}\f0\fs32 ICONAG LV-Texte\par
\pard\qc\wpparflg32\plain\f0\fs20\b B-CON Management- und Bedieneinrichtung\par
\pard\brdrb\brdrs\brdrw10\brsp20\sl360\slmult1\qc\wpparflg32\plain\f0\fs20\b  \par
\pard\plain\wpparflg32\plain\f0\fs20\b\par
\pard\tblstart1{\trowd\trleft-108\trrh1418\trgaph108\trpaddfl3\trpaddl108\trpaddfr3\trpaddr108\trftsWidth3\trwWidth9468\clshdnil\clftsWidth3\clwWidth2359\clpadfl3\clpadl20\clpadfr3\clpadr20\clpadft3\clpadt20\clpadfb3\clpadb20\clvertalt\cellx2251\clshdnil\clftsWidth3\clwWidth7109\clpadfl3\clpadl20\clpadfr3\clpadr20\clpadft3\clpadt20\clpadfb3\clpadb20\clvertalt\cellx9360\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\clshdnil\plain\f0\fs20\b Projekt:\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\clshdnil\plain\f0\fs20\b\cell\row}{\trowd\trleft-108\trrh1418\trgaph108\trpaddfl3\trpaddl108\trpaddfr3\trpaddr108\trftsWidth3\trwWidth9468\clshdnil\clftsWidth3\clwWidth2359\clpadfl3\clpadl20\clpadfr3\clpadr20\clpadft3\clpadt20\clpadfb3\clpadb20\clvertalt\cellx2251\clshdnil\clftsWidth3\clwWidth7109\clpadfl3\clpadl20\clpadfr3\clpadr20\clpadft3\clpadt20\clpadfb3\clpadb20\clvertalt\cellx9360\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\clshdnil\plain\f0\fs20\b Auftraggeber:\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\clshdnil\plain\f0\fs20\b\cell\row}{\trowd\trleft-108\trrh1418\trgaph108\trpaddfl3\trpaddl108\trpaddfr3\trpaddr108\trftsWidth3\trwWidth9468\clshdnil\clftsWidth3\clwWidth2359\clpadfl3\clpadl20\clpadfr3\clpadr20\clpadft3\clpadt20\clpadfb3\clpadb20\clvertalt\cellx2251\clshdnil\clftsWidth3\clwWidth7109\clpadfl3\clpadl20\clpadfr3\clpadr20\clpadft3\clpadt20\clpadfb3\clpadb20\clvertalt\cellx9360\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\clshdnil\plain\f0\fs20\b Erstellt von:\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\clshdnil\plain\f0\fs20\b ICONAG-Leittechnik GmbH\line Hauptstra\'DFe 189\line D-55743 Idar-Oberstein\cell\row}\tblend1\pard\plain\brdrb\brdrs\brdrw10\brsp20\sl360\slmult1\plain\f0\fs20\b  \par
\pard\plain\sl360\slmult1\wpparflg32\plain\f0\fs20\b\par
\pard\tblstart1{\trowd\trleft-108\trgaph108\trpaddfl3\trpaddl108\trpaddfr3\trpaddr108\trftsWidth2\trwWidth5000\clshdnil\clftsWidth2\clwWidth2500\clvertalt\cellx5033\clshdnil\clftsWidth2\clwWidth2500\clvertalt\cellx10171\pard\intbl\li0\fi0\ri0\sb0\sa0\sl480\slmult1\tx1276\tqr\tlul\tx4253\ql\wpparflg32\clshdnil\plain\f0\fs20\b\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\sl480\slmult1\tqr\tx4441\ql\wpparflg32\clshdnil\plain\f0\fs20\cell\row}\tblend1\pard\plain\wpparflg32\plain\f1\fs4\par
\pard\plain\plain\f1\fs4\par
\sect}\sectd\ltrsect\sbkpage\marglsxn1134\margrsxn567\margtsxn1134\margbsxn1134\headery1134\footery1134\sectdefaultcl{{\header{\sa113\wpparflg32\plain\f0\fs20\b ICONAG-Leittechnik GmbH\par
\tx1701\wpparflg32\plain\f0\fs20 Projekt:\tab  \par
\tx1701\wpparflg32\plain\f0\fs20 LV-Bezeichnung:\tab B-CON Management- und Bedieneinrichtung\par
\pard\brdrt\brdrs\brdrw15\brdrb\brdrs\brdrw15\sb113\sa113\sl288\slmult1\qc\vertalc\plain\fs20 Vorbemerkungen / Vertragstexte\par
\pard\plain\par
}}
{\footer{\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth2\clwWidth2500\clvertalt\cellx5086\clftsWidth2\clwWidth2500\clvertalt\cellx10172\pard\intbl\plain\s36\li0\fi0\ri0\sb0\sa0\ql\f2\fs18 LV-Datum: \cell\pard\intbl\plain\s37\li0\fi0\ri0\sb0\sa0\qr\f2\fs18 Seite {\field{\*\fldinst{PAGE}}{\*\fldrslt{217}}}\cell\row}\tblend1}}
\pard\plain\s0\ri1984\wpparflg32\plain\f0\fs20\b B-CON Software Version B-CON Creative Studio\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\sa200\sl288\slmult1\wpparflg32\plain\fs20\b\i B-CON Creative Studio\par
\sa0\sl0\wpparflg32\plain\fs20 Die Software muss das Erstellen von Visualisierungen f\'FCr verschiedene geb\'E4udetechnische (Bus-)Systeme,\par
\plain\fs20 das Erstellen von vernetzbaren Bedienstationen einer\par
\plain\fs20 gewerke\'FCbergreifenden Geb\'E4udeleittechnik sowie\par
\plain\fs20 das Bewirtschaften von verteilten Liegenschaften im Rahmen eines technischen Geb\'E4udemanagements erm\'F6glichen.\par
\pard\plain\ri1984\plain\fs20\par
\plain\fs20 Um den Aufwand f\'FCr Systemerstellung und Systempflege auf Dauer niedrig zu halten, muss die Software die Grundfunktionen im technischen Geb\'E4udemanagement in Form von Programmmodulen zur Verf\'FCgung stellen. Diese m\'FCssen ohne Programmieraufwand einzurichten sein. Die mindestens verf\'FCgbaren Programmmodule m\'FCssen die Grundfunktionen im technischen Geb\'E4udemanagement\par
\plain\fs20 unterst\'FCtzen. Diese m\'FCssen sein: \par
\ls23\ilvl0{\listtext\f6\fs20 \'B7\tab}\li360\fi-360\plain\fs20 zentrale Alarmverarbeitung f\'FCr alle angeschlossenen Systeme\par
{\listtext\f6\fs20 \'B7\tab}\plain\fs20 Alarmweiterleitung \'FCber Meldeprogramme an externe Stellen\par
{\listtext\f6\fs20 \'B7\tab}\plain\fs20 Zeitschaltuhr mit Wochen-, Kalender- und Ausnahmeprogrammen\par
{\listtext\f6\fs20 \'B7\tab}\plain\fs20 Datenaufzeichnung und Abruf in einem Historienmodul\par
{\listtext\f6\fs20 \'B7\tab}\plain\fs20 Lastmanagement und Trendanalyse\par
{\listtext\f6\fs20 \'B7\tab}\plain\fs20 Detektivfunktion zur Abfrage von Geb\'E4udezust\'E4nden.\par
\pard\plain\ri1984\plain\fs20\par
\plain\fs20 Weiterhin m\'FCssen die Datenpunkte aller angeschlossener Systeme in einer zentralen Objektliste verwaltet werden und von hier aus lesend und schreibend angesprochen werden k\'F6nnen. Dies ist besonders wichtig, um Inbetriebnahme und Betrieb \'FCbersichtlich und effektiv zu organisieren.\par
\pard\plain\ri1984\plain\fs20\par
\plain\fs20 Dar\'FCber hinaus muss die Software \'FCber einen grafischen Editor verf\'FCgen, der es erm\'F6glicht: \par
\ls23\ilvl0{\listtext\f6\fs20 \'B7\tab}\li360\fi-360\plain\fs20 Anlagenbilder zu erstellen Funktionen von einem oder mehreren angeschlossenen geb\'E4udetechnischen Systemen zu visualisieren\par
{\listtext\f6\fs20 \'B7\tab}\plain\fs20 Gateways zwischen diesen Systemen zu programmieren sowie\par
{\listtext\f6\fs20 \'B7\tab}\plain\fs20 Automationsroutinen mit Funktionen der Geb\'E4udetechnik, der Informations- und der Kommunikationstechnik zu erstellen.\par
\pard\plain\ri1984\plain\fs20\par
\plain\fs20 Die Software darf keinerlei softwareseitige Beschr\'E4nkungen zu der Anzahl der Datenpunkte oder Anzahl der Dialogseiten enthalten. Die Anzahl der Datenpunkte muss \'FCber Server-Lizenzen frei skalierbar sein.\par
\pard\plain\ri1984\plain\fs20\par
\plain\fs20 Zur Gew\'E4hrleistung einer \'FCberschaubaren Dokumentation muss der Editor rein grafisch arbeiten und eine Dokumentation im Quelltext erm\'F6glichen. Ein offenes Treiberkonzept muss die Kompatibilit\'E4t f\'FCr eine Vielzahl von geb\'E4udetechnischen (Bus-)Systemen sicherstellen.\par
\pard\plain\ri1984\plain\fs20\par
\plain\fs20 Die mit der Software erstellten Systeme m\'FCssen \'FCber TCP/IP vernetzbar (Intranet, Internet) sein. Die Bedienung muss wahlweise\par
\plain\fs20 lokal m\'F6glich sein oder \'FCber Internetbrowser (z. B. Mozilla Firefox, Google Chrome, MS Internet Explorer) aus der Ferne erfolgen k\'F6nnen.\par
\pard\plain\ri1984\plain\fs20\par
\plain\fs20 Die Software muss in der zum Zeitpunkt der Auftragserteilung aktuellen Releaseversion ausgeliefert werden.\par
\pard\plain\ri1984\plain\fs20\par
\tx3969\wpparflg32\plain\fs20 Technische Spezifikation B-CON:\par
\pard\plain\ri1984\tx3969\plain\fs20\par
\tx3969\plain\fs20\ul Systemvoraussetzungen:\par
\tx3969\plain\fs20 Windows 7 Professional, Windows 8.1 Pro, Windows 10 bzw. Windows 2008 R2 Server, Windows 2012 Server, Windows 2012 R2 Server, Windows 2016 Server, Windows 2019 Server, \par
\tx3969\plain\fs20 min. 8 GB RAM und 500 GB Festplattenspeicher RAID 0 oder 5\par
\pard\plain\ri1984\tx3969\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Offenes Treiberkonzept: \par
\tx3969\wpparflg32\plain\fs20 native Kommunikation mit BACnet IP, Modbus/IP und KNX\par
\tx3969\wpparflg32\plain\fs20 Kommunikation durch OPC Technologie mit allen am Markt\par
\tx3969\wpparflg32\plain\fs20 verf\'FCgbaren OPC-f\'E4higen Systemen der Geb\'E4ude- und\par
\tx3969\plain\fs20 Automatisierungstechnik.\par
\tx3969\plain\fs20 Serielle Kommunikation \'FCber\par
\tx3969\plain\fs20 RS232, RS485.\par
\tx3969\plain\fs20 Anbindungsm\'F6glichkeiten an\par
\tx3969\plain\fs20 andere Systeme \'FCber TCP/IP, UDP, Infrarot, .NET, MS-Excel, Data-Socket, ActiveX/OLE,\par
\tx3969\plain\fs20 DLL, XML\par
\tx3969\wpparflg32\plain\fs20 Mindestens \'FCber Treiber\par
\tx3969\plain\fs20 anbindbare geb\'E4udetechnische Systeme:\par
\tx3969\wpparflg32\plain\fs20 KNX, LON, BACnet, M-Bus,\par
\tx3969\wpparflg32\plain\fs20 Modbus, Profibus, Interbus,\par
\tx3969\plain\fs20 SAIA, Sauter, Kieback & Peter\par
\pard\plain\ri1984\tx3969\plain\fs20\par
\tx3969\plain\fs20\ul Daten\'FCbernahme:\par
\tx3969\plain\fs20 Die Datenpunktliste muss direkt\par
\tx3969\plain\fs20 aus den \'FCber OPC angeschlossenen\par
\tx3969\plain\fs20 Systemen einlesbar sein (z. B.ETS f\'FCr KNX).\par
\pard\plain\ri1984\tx3969\plain\fs20\par
\tx3969\wpparflg32\plain\fs20 F\'FCr BACnet muss das System gew\'E4hrleisten, dass sowohl \par
\tx3969\wpparflg32\plain\fs20 verf\'FCgbare BACnet Ger\'E4te im Netzwerk gescannt werden \par
\tx3969\wpparflg32\plain\fs20 k\'F6nnen. F\'FCr die Offline-Projektierung muss jedoch das \par
\tx3969\wpparflg32\plain\fs20 Einlesen von EDE-Files ebenfalls m\'F6glich sein.\par
\pard\plain\ri1984\tx3969\plain\fs20\par
\tx3969\plain\fs20\ul Datenpunktverwaltung:\par
\tx3969\plain\fs20 Die Software muss eine objektorientierte Verwaltung der\par
\tx3969\plain\fs20 Datenpunkte in einer Tabelle erm\'F6glichen. In dieser Tabelle m\'FCssen die Datenpunkte aller angeschlossener Systeme zentral verwaltet werden (Objektliste). Jeder Datenpunkt muss entsprechend dem Datentyp aus dieser Liste lesend und schreibend ansprechbar sein, ohne dass es eine Verkn\'FCpfung des Datenpunktes innerhalb einer \par
\tx3969\plain\fs20 Visualisierungsseite bedarf.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\ul\par
\tx3969\wpparflg32\plain\fs20\ul Multitasking, Skalierung: \par
\tx3969\wpparflg32\plain\fs20 Die Software muss Multithreading und\par
\tx3969\plain\fs20 Multiprozessor Systeme optimal unterst\'FCtzen. Es muss eine eventgesteuerte Ausf\'FChrung und Abarbeitung s\'E4mtlicher Systemfunktionen unterst\'FCtzen.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Programmmodule Zeitmanagement:\par
\tx3969\wpparflg32\plain\fs20 Das Zeitmanagement muss die Verwaltung von beliebig vielen Zeitschaltprogrammen in Form von Wochen-, Kalender-und Ausnahmeprogrammen erm\'F6glichen. Jedes Programm muss beliebig viele Objekte schalten k\'F6nnen.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Alarm- und St\'F6rmeldeverarbeitung\ulnone :\par
\tx3969\wpparflg32\plain\fs20 Die Alarmverarbeitung muss eine tabellenorientierte\par
\tx3969\plain\fs20 Darstellung, Bearbeitung und Protokollierung von\par
\tx3969\plain\fs20 Alarmmeldungen und Reaktionen auf Alarmmeldungen erm\'F6glichen.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\plain\fs20\ul Nachrichtenweiterleitung\par
\tx3969\wpparflg32\plain\fs20\ul und Kommunikation:\par
\tx3969\wpparflg32\plain\fs20 Die Nachrichtenmanagement muss die Verwaltung von\par
\tx3969\plain\fs20 Meldeprogrammen zur Weiterleitung von St\'F6rungen\par
\tx3969\plain\fs20 und Anlagenzust\'E4nden per E-Mail, SMS, Text-to-Speech \par
\tx3969\plain\fs20 und anderen g\'E4ngigen Diensten erm\'F6glichen.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\ul\par
\tx3969\wpparflg32\plain\fs20\ul Historienmodul:\par
\tx3969\wpparflg32\plain\fs20 Das Historienmodul muss die Aufzeichnung von Zust\'E4nden\par
\tx3969\plain\fs20 erm\'F6glichen. Die Aufzeichnung muss Online bei Wert\'E4nderung erfolgen, wobei eine Hysterese einstellbar sein muss. Daten m\'FCssen in einer frei w\'E4hlbaren\par
\tx3969\plain\fs20 Datenbank gespeichert werden k\'F6nnen. Die Darstellung der Daten muss in Form von frei w\'E4hlbaren Diagramme\par
\tx3969\plain\fs20 erfolgen. Auf Wunsch des Betreibers m\'FCssen \par
\tx3969\plain\fs20 Gruppennamen vergeben werden k\'F6nnen, die sp\'E4ter aus \par
\tx3969\plain\fs20 dem Programmmodul aufgerufen werden k\'F6nnen. Die \par
\tx3969\plain\fs20 Zuordnung und die Namensgebung der Historiengruppen m\'FCssen f\'FCr den Betreiber frei w\'E4hlbar sein. Hierbei sind alle Standardtypen an Diagrammen (S\'E4ule, Balken, Linie, Kreis) vorzuhalten.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Energie- und Lastmanagement:\par
\tx3969\wpparflg32\plain\fs20 Das Programmmodul muss zur Optimierung des Leistungspreises beim Strombezug durch \'FCber eine\par
\tx3969\plain\fs20 Trendprognose optimierte Zu- und Abschaltung von\par
\tx3969\plain\fs20 Verbrauchern beitragen. Verbraucherspezifische\par
\tx3969\plain\fs20 Schaltzeiten m\'FCssen ber\'FCcksichtigt werden. Es\par
\tx3969\plain\fs20 k\'F6nnen beliebig viele Verbraucher in allen\par
\tx3969\plain\fs20 angeschlossenen Systemen einbezogen werden.\par
\tx3969\plain\fs20 F\'FCr Auswertungen archivierter Lastverl\'E4ufe muss ein\par
\tx3969\plain\fs20 grafisches Auswertewerkzeug zur Verf\'FCgung stehen.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Zustandsabfrage, Detektiv:\par
\tx3969\wpparflg32\plain\fs20 Konkrete Geb\'E4udezust\'E4nde m\'FCssen in Klartextabfragen\par
\tx3969\plain\fs20 m\'F6glich sein, wie z. B. \u8222 ?Welche Fenster stehen noch offen?\u8220 ?\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Berechtigungsvergabe:\par
\tx3969\wpparflg32\plain\fs20 Die Berechtigungsvergabe muss die Vergabe und\par
\tx3969\plain\fs20 Verwaltung von beliebig vielen Nutzern und\par
\tx3969\plain\fs20 Berechtigungsprofilen erm\'F6glichen. Die Nutzer sind\par
\tx3969\plain\fs20 den Berechtigungsprofilen zuordenbar. Des weiteren \par
\tx3969\plain\fs20 m\'FCssen dem Benutzer bereits entsprechende Alarmprofile\par
\tx3969\plain\fs20 zugeordnet werden k\'F6nnen, z. B. Alarmbediener oder \par
\tx3969\plain\fs20 Alarmbetrachter. S\'E4mtliche Zugriffsrechte, ganz gleich ob bei lokaler Anmeldung oder bei Anmeldung \'FCber das HTML5-basierte Intranetportal m\'FCssen in der Berechtigungsvergabe vorgenommen werden. \par
\tx3969\plain\fs20 Alle Systemzug\'E4nge und Ver\'E4nderungen sind zu protokollieren.\par
\pard\plain\ri1984\tx3969\plain\fs20\par
\tx3969\plain\fs20\ul Web-Server, Internet-Bedienung:\par
\tx3969\plain\fs20 Das System muss \'FCber einen integrierten Webserver\par
\tx3969\plain\fs20 verf\'FCgen. Dieser muss s\'E4mtliche Visualisierungsseiten \par
\tx3969\plain\fs20 im HTML5-Format (ohne zus\'E4tzliche PlugIns wie Active \par
\tx3969\plain\fs20 X, Silverlight, o. a.) zur Anzeige und Bedienung per\par
\tx3969\plain\fs20 Internetbrowser (z. B. MS Explorer, Mozilla Firefox oder Google Chrome) im Netzwerk publizieren k\'F6nnen. Es muss m\'F6glich sein, die Serverzugriffe durch Vergabe von\par
\tx3969\plain\fs20 Benutzerberechtigungen und Berechtigungsstufen\par
\tx3969\plain\fs20 einzuschr\'E4nken. Eine sichere Fernbedienung \'FCbers Internet \'FCber das Fernwirkportal der ICONAG und \'FCber VPN-Dienste muss m\'F6glich sein.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\plain\fs20\ul Editor:\par
\tx3969\wpparflg32\plain\fs20\ul Online-Editierung:\par
\tx3969\wpparflg32\plain\fs20 Das System muss erm\'F6glichen, dass im Betrieb einzelne Seiten editiert werden k\'F6nnen, w\'E4hrend das Projekt mit seinen Funktionen online weiter arbeitet.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Bibliotheken zur Visualisierung:\par
\tx3969\wpparflg32\plain\fs20 Es m\'FCssen Bibliotheken mit bin\'E4ren, numerischen und\par
\tx3969\plain\fs20 alphanumerischen Ein- und Ausgabeelemente zur\par
\tx3969\plain\fs20 Verf\'FCgung stehen. Die Elemente m\'FCssen durch\par
\tx3969\plain\fs20 Anpassungen in Gr\'F6\'DFe, Form und Farbe frei editierbar sein, um den Designanforderungen des Kunden gerecht zu werden. Der Farb- und Textumschlag muss in den Bedien- und Anzeigenelementen abgelegt sein. Die Bedien- und\par
\tx3969\plain\fs20 Anzeigeelemente sind als 2D und 3D Elemente verf\'FCgbar.\par
\pard\plain\ri1984\tx3969\plain\fs20\par
\tx3969\plain\fs20\ul Chart- und Trendschreiber:\par
\tx3969\plain\fs20 Der Editor muss frei skalierbare bis zu 8-kanalige\par
\tx3969\plain\fs20 OnlineSchreiber (x/t, x/y) verf\'FCgen. Dieser muss als\par
\tx3969\plain\fs20 Ringspeicher ausgelegt sein und eine Datenbankanbindung\par
\tx3969\plain\fs20 erm\'F6glichen. \par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Historische Daten:\par
\tx3969\wpparflg32\plain\fs20 Das Speichern historischer Daten muss wahlweise als\par
\tx3969\plain\fs20 Textdatei, als Excel\u61666 ?-Datei sowie in eigenen Datenbanken m\'F6glich sein. Bei steigendem Datenaufkommen muss eine Erweiterung der Speicherung in externen Datenbanken \'FCber ODBC/SQL (Access, MS-SQL, Cybase, Oracle etc.) jederzeit m\'F6glich sein.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Einbinden von Grafiken:\par
\tx3969\wpparflg32\plain\fs20 Grafiken zur Visualisierung und Darstellung von Geb\'E4ude- und Anlagenbildern m\'FCssen mindestens im Bitmap- und\par
\tx3969\plain\fs20 Vektorgrafikformat eingebunden werden k\'F6nnen\par
\tx3969\plain\fs20 (EMF, WMF, BMP, JPEG, GIF, CLP, Animated GIF)\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Einbinden von ActiveX:\par
\tx3969\wpparflg32\plain\fs20 Das Einbinden von ActiveX Containern (zur vollst\'E4ndigen\par
\tx3969\plain\fs20 Integration fremder Windowsapplikationen) muss\par
\tx3969\plain\fs20 m\'F6glich sein, hierbei insbesondere zur Integration von Videobildern/Webcams in die Bedienoberfl\'E4che.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\tx3969\wpparflg32\plain\fs20\ul Gatewayfunktionalit\'E4t:\par
\tx3969\wpparflg32\plain\fs20 S\'E4mtliche aufgeschaltete Systeme k\'F6nnen rein grafisch\par
\tx3969\plain\fs20 und datenpunktorientiert miteinander verkn\'FCpft werden.\par
\tx3969\plain\fs20 Daf\'FCr m\'FCssen auch komplexe Logikfunktionen (digital,\par
\tx3969\plain\fs20 mathematisch und vergleichend) zur Verf\'FCgung stehen.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\par
\plain\fs20\ul Multi-Media-Funktion,\par
\tx3969\wpparflg32\plain\fs20\ul Speicherprogrammierbare Steuerung;\par
\tx3969\wpparflg32\plain\fs20 Alle Funktionen der Geb\'E4udetechnik m\'FCssen beliebig mit Funktionen der Informationstechnik (z. B. Datenbankankopplung, Start, Fernbedienung und Beenden\par
\tx3969\plain\fs20 anderer Windowsanwendungen) und der Kommunikationstechnik (Versenden von SMS, E-Mail,\par
\tx3969\plain\fs20 Fax oder Pager, \'D6ffnen, \'DCbertragen von Daten sowie\par
\tx3969\plain\fs20 Schlie\'DFen von Verbindungen \'FCber TCP/IP) verkn\'FCpft werden k\'F6nnen. Daf\'FCr m\'FCssen auch komplexe Logikfunktionen (digital, mathematisch und vergleichend) sowie Zeitbausteine (Timer f\'FCr Jahr, Monat, Tag, Stunden, Minuten, Sekunden, letzter Tag im Monat, Stoppuhr etc.) zur Verf\'FCgung stehen.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\ul\par
\tx3969\wpparflg32\plain\fs20\ul Makrof\'E4higkeit:\par
\tx3969\wpparflg32\plain\fs20 Alle einmal entworfenen Funktionen m\'FCssen in Form\par
\tx3969\plain\fs20 von Makrobausteinen (Sub-VI) abgelegt werden k\'F6nnen, um in anderen Programmen wieder eingesetzt werden zu k\'F6nnen. Damit muss eine ereignisbasierte und objektorientierte Projektierung sichergestellt werden.\par
\pard\plain\ri1984\tx3969\plain\fs20\ul\par
\tx3969\plain\fs20\ul Funktionsbibliotheken:\par
\tx3969\plain\fs20 F\'FCr die Programmierung muss eine umfangreiche\par
\tx3969\plain\fs20 Funktionsbibliothek f\'FCr logische, mathematische und\par
\tx3969\plain\fs20 vergleichende Operationen zur Verf\'FCgung stehen. Weiterhin m\'FCssen umfangreiche Funktionsmodule f\'FCr die\par
\tx3969\plain\fs20 Automatisierung und Programmierung von Makros (Sub-VI) und kompletten Programmodulen (Plug-Ins) zur\par
\tx3969\plain\fs20 Verf\'FCgung stehen.\par
\pard\plain\ri1984\wpparflg32\plain\fs20\ul\par
\tx3969\wpparflg32\plain\fs20\ul Zusatzmodule:\par
\tx3969\wpparflg32\plain\fs20 Es muss ohne weiteres m\'F6glich sein, Zusatzmodule in Form von PlugIns oder Add On\'B4s in die Applikation zu integrieren. Diese Zusatzmodule m\'FCssen Versions\'FCbergreifend zur Verf\'FCgung stehen. Beispiele f\'FCr solche Funktionsmodule sind z.B. Alarmierung nach\par
\tx3969\plain\fs20 Bereitschaftsplan, Verteilung von Energiedaten auf einzelne Kostenstellen, etc.\par
\pard\plain\ri1984\tx3969\plain\fs20\par
\pard\plain\ri1984\tx3969\plain\fs20\par
\tx3969\plain\fs20 Hersteller: ICONAG\par
\tx3969\wpparflg32\plain\fs20 Typ: B-CON Creative Studio\par
\pard\plain\sa454\plain\fs20\par
\sa0\wpparflg32\plain\fs20 Management- und Bedieneinrichtung\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Um auch zuk\'FCnftig die Aufschaltung von beliebigen Automatisierungs- und Herstellersystemen gew\'E4hrleisten zu k\'F6nnen sowie die Vernetzung mit anderen Standorten sicherzustellen, ist eine herstellerneutrale Management- und Bedieneinrichtungen mit Energie-Management-System vorzusehen, die auch ein zentrales Management aller Liegenschaften optimal unterst\'FCtzt (im Weiteren MBE).\par
\plain\fs20 F\'FCr die Installation und den Betrieb der Server-Anwendung sind zwei redundante Server zu liefern (Hot-Standby Redundanz). Die Lizensierung der MBE-Software hat mittels Softwaredongle zu erfolgen. Die Lizensierung mittels USB-Hardware-Dongle muss alternativ m\'F6glich sein.\par
\plain\fs20 Die Lizensierung f\'FCr die MBE-Software darf lediglich auf Basis der aufzuschaltenden Datenpunkte, der Funktionsmodule sowie der zeitgleichen Benutzerzugriffe (Concurrent User) via Webbrowserclients erfolgen. \par
\plain\fs20 Die Hardware und Lizenzierung der Managment- und Bedieneinrichtung ist so auszulegen, dass zu einem sp\'E4teren Zeitpunkt das im Bestand befindliche MBE-System abgel\'F6st und die Bestandsanlagen mit ca. 30.000 Datenpunkten aufgeschaltet werden k\'F6nnen.\par
\plain\fs20 Die Dienstleistungen hierf\'FCr sind kein Bestandteil der vorliegenden Ausschreibung.\par
\pard\plain\plain\fs20\par
\plain\fs20 Die nachfolgenden Funktionen m\'FCssen vollumf\'E4nglich und ohne weitere Lizenzierung im Softwarepaket enthalten und nutzbar sein:\par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20 Native Treiber-Schnittstellen zu BACnet, KNX und Modbus\par
\plain\fs20 OPC-DA-Client\par
\plain\fs20 Benutzerverwaltung mit der M\'F6glichkeit eine beliebige Anzahl an Benutzern und Profilen anzulegen.  \par
\plain\fs20 Webserver f\'FCr Anzeige und Bedienung\par
\plain\fs20 Verwaltung und Bereitstellung einer unbegrenzten Anzahl von Browser-Anlagenbildern in HTML5-Technik\par
\plain\fs20 Umfangreiche Bibliothek an Anzeige und Bedienelementen zur Erstellung von Browser-Anlagenbildern\par
\plain\fs20 Spezialbibliothek f\'FCr BACnet-Objekte, mindestens zur Visualisierung folgender Objekttypen: Analog, Binary und Multistate Objekte, Scheduler Objekte, Device Objekte\par
\plain\fs20 M\'F6glichkeit der Erstellung eigener Anzeige- und Bedienelemente (Webcontrols) aus eigenem Bildmaterial\par
\plain\fs20 Zentrale Objektliste f\'FCr Anzeige und Bedienung mit umfangreichen Filterm\'F6glichkeiten \'FCber vorgegebene oder individuelle Filterkriterien \par
\plain\fs20 Plug-In-Funktionalit\'E4t zur Erstellung projektspezifischer Anwendungs-, Regel- oder Gateway-Funktionen\par
\pard\plain\plain\fs20\par
\plain\fs20 Folgende Managementfunktionen sind ohne weitere Lizenzierung vorgeschrieben:\par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20 Alarm- und Eventmanagement mit Meldungsversand via E-Mail und SMS. Hierbei k\'F6nnen Meldeprogramme in unbegrenzter Anzahl mit beliebiger Anzahl an Empf\'E4ngern eingerichtet werden. Die Empf\'E4nger k\'F6nnen hierbei entweder aus der Benutzerverwaltung \'FCbernommen werden oder es m\'FCssen externe Empf\'E4nger eingepflegt werden k\'F6nnen. \par
\plain\fs20 Trendmanagement zur Fehleranalyse und Langezeitarchivierung\par
\plain\fs20 Energiemanagement\par
\plain\fs20 Zeitplanmanagement \'FCber BACnet Controls\par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20 F\'FCr die Aufschaltung der unterlagerten Automationsstationen ist als Kommunikationsprotokoll BACnet/IP vorgesehen. Die Automationsstationen m\'FCssen mindestens die BACnet-Revision 1.12, die MBE-Software muss mindestens die BACnet-Revision 1.18 unterst\'FCtzen. Um den Mehrwert des BACnet-Protokolls optimal nutzen zu k\'F6nnen, muss die MBE-Software mindestens folgende Funktionen unterst\'FCtzen:\par
\wpparflg32\plain\fs20 Die MBE-Software muss die Funktion des Zeitmasters im BACnet-Netzwerk unterst\'FCtzen. Diese Funktion ist vom Errichter der MBE einzurichten.\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Die MBE-Software muss die M\'F6glichkeit bieten als BACnet Server zu fungieren und eigene BACnet Objekte im Netzwerk zur Verf\'FCgung zu stellen, um z.B. anderen Systemen (z.B. Systemen mit besonderen Aufgaben, CAFM-System, etc.) gezielte Informationen aus der Geb\'E4udeautomation zur Verf\'FCgung zu stellen.  \par
\wpparflg32\plain\fs20  \par
\wpparflg32\plain\fs20 Notification Class Objekte:\par
\wpparflg32\plain\fs20\'DCber das Intrinsic Alarming und Notification Class Objekte (NC) erfolgt in den Automationsstationen (AS) das eventbasierte Melden von Alarmen und Meldungen aufgeteilt in verschiedene Meldungspriorit\'E4ten an die MBE. Hierzu muss es m\'F6glich sein \'FCber einen vordefinierten Filter in der zentralen Objektliste der MBE die Notification Class Objekte aller ASen herauszufiltern und mittels Mehrfachauswahl und einfacher Zuweisung zeitgleich alle NCs dem Alarm- und Eventmanagement zuzuf\'FChren. Anschlie\'DFend muss die MBE-Software in der Lage sein alle \'FCber die NCs erhaltenen Alarme und Meldungen in der Meldungsliste darzustellen.\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Scheduler Objekte:\par
\wpparflg32\plain\fs20 Zeitschaltfunktionen sind in den ASen ausnahmslos mittels BACnet Scheduler Objekten (SC) zu realisieren. Auf der MBE m\'FCssen die Scheduler Objekte unmittelbar aus der Objektliste heraus aufgerufen und mittels intuitiver Bedienoberfl\'E4che bedienbar sein. In den Anlagenbildern sind die Scheduler-Objekte mittels einfacher Schaltfl\'E4chen den Anlagen zuzuordnen und \'FCber diese aufrufbar. Die Bedienung erfolgt \'FCber identische Bedienoberfl\'E4chen.\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Device Objekte\par
\wpparflg32\plain\fs20 Um die Kommunikation zu den aufgeschalteten ASen zu \'FCberwachen ist in der MBE eine automatische \'DCberwachungsroutine implementiert. Nach einem einmin\'FCtigen Verbindungsausfall ist ein Alarm in der MBE auszul\'F6sen. Die Status der aufgeschalteten ASen sind auf einem Anlagenbild darzustellen. Hierf\'FCr stehen in der MBE-Software schl\'FCsselfertige WebControls f\'FCr das Device Objekt zur Verf\'FCgung. Das Control zeigt dem Bediener den Objekt-, den Hersteller-, sowie den Modell-Namen an. \'DCber eine gr\'FCne LED im Control wird der aktuelle Verbindungsstatus signalisiert. \'DCber eine Schaltfl\'E4che auf dem Control l\'E4sst sich ein PopUp-Dialog \'F6ffnen, in dem in tabellarischer Form alle Properties des zugeh\'F6rigen Device Objektes dargestellt werden. \par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Analog, Binary und Multistate Objekte (jeweils Input-, Output- und Value-Objekte)\par
\wpparflg32\plain\fs20 F\'FCr Analog, Binary und Multistate Objekte m\'FCssen in der MBE-Software schl\'FCsselfertige WebControls zur Verf\'FCgung stehen.  Die Controls f\'FCr Binary-, Analog- und Multistate-Objekte m\'FCssen vom grunds\'E4tzlichen Aufbau her identisch sein.\par
\plain\fs20 Jedes Control muss aus einem numerischen (Analog Control) bzw. einem String-Anzeigeelement (Binary, Multistate) zur Anzeige des Present-Value bestehen. Linksseitig davon ist in einem Anzeigeelement die aktive Priority (bei vorhandenem Priority-Array) anzuzeigen. F\'FCr die Priority \u8222 ?16\u8220 ? wird ein A-Symbol, f\'FCr die Priority \u8222 ?8\u8220 ? ein Hand-Symbol angezeigt. Alle \'FCbrigen Priorities werden durch ein rotes Ausrufezeichen-Symbol dargestellt. Projektspezifisch m\'FCssen die Symbole der einzelnen Priorities austauschbar sein. Unterhalb der Anzeigeelemente von Present-Value und Priority-Array befindet sich die Status-Flag-Anzeige. \'DCber vier Symbole (inAlarm, Fault, Overridden, Out-of-Service) muss die Aktivit\'E4t der Status-Flags angezeigt werden k\'F6nnen.\par
\plain\fs20 Befindet sich ein BACnet-Objekt im Alarmzustand muss dies einerseits \'FCber ein rot leuchtendes Glockensymbol in der Status-Flag-Anzeige sowie \'FCber einen roten Rahmen um das Control signalisiert werden k\'F6nnen. Beim Analog-Control muss der Alarmrahmen zus\'E4tzlich durch ein blaues \u8222 ?LL\u8220 ? (Low-Limit) oder rotes \u8222 ?HL\u8220 ? (High-Limit) bei einer entsprechenden Grenzverletzung unterbrochen werden. Jeder Controltyp muss zus\'E4tzlich in einer \u8222 ?Simple\u8220 ?-Version verf\'FCgbar sein. Die \u8222 ?Simple\u8220 ?-Version unterscheidet sich hierbei lediglich durch das Weglassen der Status-Flag-Anzeige. Die \'FCbrigen Funktionalit\'E4ten bleiben davon unber\'FChrt.\par
\plain\fs20 Durch einen linken Mausklick auf ein Control muss sich ein  \u8222 ?Eigenschaften\u8220 ?-Men\'FC \'F6ffnen.\par
\plain\fs20 Abh\'E4ngig vom Objekt-Typ erlangt der Bediener \'FCber das \u8222 ?Eigenschaften\u8220 ?-Men\'FC Zugriff auf die wichtigsten Properties des ausgew\'E4hlten BACnet-Objektes.\par
\wpparflg32\plain\fs20 Diese sind u.a.: Object-Name, -Description, -Type, Instance-Number, Event-State, Relinquish Default, Priority, Priority-Array, Present Value, Status-Flags, Limits, Alarm-Value, States, State-Texts.\par
\wpparflg32\plain\fs20\'DCber das \u8222 ?Eigenschaften\u8220 ?-Men\'FC muss die Property Present-Value beschrieben werden k\'F6nnen. Das Zur\'FCcksetzen eines Wertes muss durch das Schreiben von "Null" m\'F6glich sein. Bei vorhandenem Priority-Array ist die Standard-Schreibpriorit\'E4t "8" voreingestellt. \par
\plain\fs20 Die Schreibpriorit\'E4t muss \'FCber das \u8222 ?Eigenschaften\u8220 ?-Men\'FC individuell \'E4nderbar sein.\par
\plain\fs20 Die Eigenschaft "Out-Of-Service" muss gesetzt werden k\'F6nnen.\par
\plain\fs20 Bei Analog-Objekten m\'FCssen zus\'E4tzlich die Properties High- und Low-Limit aktiv/deaktiv sowie die Grenzen einstellbar sein.\par
\plain\fs20 Bei Binary- und Multistate-Objekten ist zus\'E4tzlich das Property Alarm-Value \'E4nderbar.\par
\wpparflg32\plain\fs20 Jedes BACnet-Objekt muss dar\'FCber hinaus im Anlagenbild durch die Verkn\'FCpfung einzelner Properties mit dynamischen Anzeige- und Bedienelementen darstellbar sein.\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111847}Bedienkonzept{\*\bkmkend _Toc31111847}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Der Bediener-Zugriff hat ausschlie\'DFlich mittels g\'E4ngigen Webbrowsern auf beliebigen Endger\'E4ten im Netzwerk des MBE-Servers zu erfolgen. F\'FCr die Realisierung der webbasierten MBE-Clients ist ausschlie\'DFlich native HTML5-Technik zugelassen. Die Verwendung von jeglichen Browser-PlugIns (z.B. Java, Silverlight, o. \'E4.) oder die Installation von Zusatzsoftware auf den Bedien-Clients zum Betrieb der Browser-Bedienoberfl\'E4chen ist nicht zul\'E4ssig. Durch den Zugriff mittels Webbrowser auf die MBE ist es dem Kunden m\'F6glich jederzeit eigenst\'E4ndig neue Bedienpl\'E4tze mit beliebigen eigenen Endger\'E4ten, die \'FCber einen HTML5-f\'E4higen Browser verf\'FCgen, einzurichten. Die Kommunikation zwischen der Browser-Oberfl\'E4che und dem MBE-Server muss mit einer https-Verschl\'FCsselung ausgestattet werden. Ein entsprechendes https-Zertifikat wird vom AG beigestellt.\par
\plain\fs20 Wird die URL der Weboberfl\'E4che in einem Browser aufgerufen, gelangt der Benutzer zun\'E4chst auf eine Login-Seite. Eine Authentifizierung mit Benutzername und Passwort ist zwingend erforderlich. Es muss die M\'F6glichkeit bestehen, die Systemsprache des Browser-Portals mit jedem Login mittels Auswahldialog zwischen deutscher und englischer Sprache umzustellen.\par
\plain\fs20 Nach dem Login gelangt der Benutzer auf die Startseite des Browser-Portals. Das Browser-Portal ist vom Aufbau her dreigeteilt aufzubauen, bestehend aus Hauptfenster, Statusleiste und Hauptnavigation. Die Statusleiste und die Hauptnavigation bleiben zu jederzeit sichtbar, k\'F6nnen bei Bedarf aber vom Benutzer ein- und ausgeblendet werden, um den Bildbereich des Hauptfensters zu vergr\'F6\'DFern.     \par
\plain\fs20 Am oberen Bildschirmrand befindet sich die Statusleiste \'FCber die dem Bediener der aktuelle Status von anstehenden Alarmen, Warnungen und Meldungen signalisiert wird. Mit einem Klick auf das Anzeigeelement \'F6ffnet sich im Hauptfenster der Alarm- und Eventmanager. Daneben ist in der Statusleiste der aktuell angemeldete Benutzer anzuzeigen und \'FCber einen Button das Ausloggen zu erm\'F6glichen.\par
\plain\fs20\'DCber die linksseitige Hauptnavigation erh\'E4lt der Benutzer in Abh\'E4ngigkeit seiner Benutzerrechte Zugriff auf die Hauptbereiche Visualisierungsseiten, Energiedaten und System.\par
\plain\fs20 Unter dem Reiter \u8222 ?Visualisierungsseiten\u8220 ? ist ein Navigationsbaum zum direkten Aufruf von Anlagenbildern darzustellen. Hierbei sind alle Anlagenbilder in eine topologisch sinnvolle Ordnerstruktur, z.B. Geb\'E4ude, Ebene, Raum und Gewerk, einzusortieren. Die genaue Struktur ist vor der Umsetzung mit dem AG abzustimmen. \par
\plain\fs20 Neben dem direkten Sprung auf ein bestimmtes Anlagenbild \'FCber den Navigationsbaum muss eine Navigation auch rein \'FCber die Anlagenbilder m\'F6glich sein. Hierzu sind Navigations-Schaltfl\'E4chen auf allen Anlagenbildern in \u8222 ?Top-Down\u8220 ?- und \u8222 ?Bottom-Up\u8220 ?-Technologie zu implementieren. Hierdurch ist es m\'F6glich von der Standort-\'DCbersichtsseite schrittweise bis in jede Anlagen- oder Raumbedienseite und zur\'FCck zu navigieren. \par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111848}Anlagenbilder{\*\bkmkend _Toc31111848}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20\'DCbersichts-, Anlagen- und Detailbilder sind gem\'E4\'DF den von der Planung \'FCbergebenen Grundrissen, GA-Funktionslisten und MSR-Schemen zu erstellen. Dabei ist darauf zu achten, dass die MSR-Schemen nicht unbedacht in die MBE-Software \'FCbernommen werden, sondern Anlagenbilder zu erstellen sind, die eine Anlage immer in einem sinnvollen Gesamtkontext darstellen. Anlagenbauteile (z.B. Pumpe, L\'FCfter, Ventil) sind in Abh\'E4ngigkeit vom ausgef\'FChrten Automatisierungsgrad als dynamische Bildelemente (Control) darzustellen. \par
\plain\fs20 Ist ein Bauteil aus bzw. nicht in Betrieb ist das jeweilige Control in grau darzustellen. Im Betrieb hat ein gr\'FCner, bei einer Warnung ein gelber und bei einer St\'F6rung ein roter Farbumschlag den jeweiligen Zustand zu signalisieren. Soll- und Istwert-Anzeigen sind in numerischen Anzeigefeldern neben dem jeweiligen Bauteil in einheitlichen Dialogfeldern anzuordnen. Sollwertanzeigen sind gelb zu umranden. Jegliche anlagenbezogenen Stelleingriffe m\'FCssen \'FCber PopUp-Dialoge erfolgen, um ein versehentliches Bedienen oder \'C4ndern von Sollwerten zu verhindern. Dies ist im Besonderen f\'FCr m\'F6gliche Bedienungen \'FCber Touch-Displays erforderlich. Der Aufruf der Popup-Dialoge erfolgt \'FCber separate Schaltfl\'E4chen, die ebenfalls dem jeweiligen Bauteil zuzuordnen sind. \par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111849}Trendauswertungen{\*\bkmkend _Toc31111849}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\pard\plain\wpparflg32\plain\fs20\par
\plain\fs20 F\'FCr die Langzeitspeicherung von Trenddaten ist vom Errichter der MBE eine Microsoft SQL Standard Datenbank zu liefern und einzurichten. Optional muss es m\'F6glich sein, dass ein vom Auftraggeber im Netzwerk bereitgestellter Microsoft SQL Server an die MBE Software angebunden werden kann. Zu historisierende und f\'FCr Trendauswertungen zur Verf\'FCgung stehende Datenpunkte sind vom Errichter auf der MBE Software einzurichten. Hierbei sind mindestens alle Soll-, Ist- und Stellwertdatenpunkte, sowie Betriebsstunden-, Betriebsart- und Alarmdatenpunkte zu historisieren. Die genaue Festlegung der zu historisierenden Datenpunkte, auch in Bezug auf die Speicherart und -tiefe, sind vor Projektbeginn mit dem Planer und dem Auftraggeber abzustimmen.  \par
\plain\fs20 Trend-Ansichten sind je Anlage aus dem Anlagenbild als Popup-Dialoge aufrufbar. Diese Trendansichten sind vom Projektierer mit der Erstellung der Anlagenbilder einzurichten. Eine Trendansicht muss ein Linien-Diagramm, ein Balkendiagramm oder eine Kombination von zwei Diagrammen enthalten k\'F6nnen. Jedes Diagramm muss bis zu 8 Trend-Datenpunkte darstellen k\'F6nnen. Beim Aufruf einer Trendansicht sind diese standardm\'E4\'DFig mit einer Auswertung der vergangenen 24 Stunden zu initialisieren. Der Bediener muss die M\'F6glichkeit haben den Auswertezeitraum beliebig auf einen ausw\'E4hlbaren vorgegebenen Zeitraum (z.B. letzte 60 Minuten, letzte volle Stunde, letzter voller Tag, letzter Monat, letztes volles Jahr) oder einen benutzerdefinierten Zeitraum mit der Vorgabe von Datum und Uhrzeit f\'FCr Beginn und Ende der Auswertung zu \'E4ndern. In Linien-Diagrammen muss es au\'DFerdem m\'F6glich sein den Auswertezeitraum durch Aufziehen eines Zeitbereichs mit dem Mauszeiger zu \'E4ndern. In Balkendiagramm muss es m\'F6glich sein durch einen Mausklick auf einen Balken in den zugeh\'F6rigen Auswertezeitraum zu springen. Aus dem Trendfenster heraus muss es m\'F6glich sein eine Trendansicht in einen Report im PDF- oder XLSX-Format oder die Rohdaten in eine CSV-Datei zu exportieren.\par
\plain\fs20 Zus\'E4tzlich muss es m\'F6glich sein \'FCber ein zentrales Trendmodul individuelle Trendansichten zu erzeugen. Hierbei m\'FCssen alle Trenddatenpunkte, auch anlagen-, geb\'E4ude- und liegenschafts\'FCbergreifend, beliebig in einer Auswertung kombiniert werden k\'F6nnen.  \par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111850}Zeitschaltprogramme{\*\bkmkend _Toc31111850}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Zeitschaltprogramme sind als BACnet-Scheduler auf den Automationsstationen anzulegen und zu parametrieren. Die MBE-Software muss es erm\'F6glichen diese aus den Automationsstationen auszulesen, aufzurufen und zu bedienen. Die BACnet-Schedule Objekte sind mittels Schaltfl\'E4chen den entsprechenden Anlagenbildern zuzuordnen und \'FCber diese vom Bediener im Betrieb zur Bedienung aufrufbar. Zeitschaltpunkte m\'FCssen vom Bediener ge\'E4ndert, gel\'F6scht oder neu erstellt werden k\'F6nnen und gem\'E4\'DF BACnet-Spezifikation direkt in das betreffende Schedule-Objekt in der Automationsstation geschrieben werden.\par
\wpparflg32\plain\fs20 Dar\'FCber hinaus muss die MBE-Software ein zentrales Modul f\'FCr Zeitschaltfunktionen zur Verf\'FCgung stellen. \par
\wpparflg32\plain\fs20 Diese Zeitschaltuhr erm\'F6glichlkt es beleibig vile Zeitschaltporgamme ohne weitere Lizenzierung anzulegen und zu parametrieren. In jedem Zeitschaltprogramm muss eine beliebeige Anzahl an Datenpunkte aus beliebiegen Quellen und Typisierung angelegt und beschaltet werden k\'F6nnen.\par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111851}Alarm- und Ereignismanagement{\*\bkmkend _Toc31111851}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Alarm- und Ereignismeldungen m\'FCssen in der MBE-Software nach Alarmen, Warnungen und Meldungen kategorisiert und beliebigen Priorit\'E4ten zugeordnet werden k\'F6nnen.\par
\plain\fs20 Alarm- und Ereignismeldungen m\'FCssen je Benutzer vorgefiltert werden k\'F6nnen. Eine Filterung muss hierbei z.B. \'FCber den BAS/AKS nach Liegenschaft, Geb\'E4ude oder Anlage/Gewerk m\'F6glich sein. \par
\plain\fs20 In Abh\'E4ngigkeit von den individuellen Berechtigungen kann ein Benutzer die ihm zugeordneten Alarm- und Ereignismeldungen jederzeit im Alarm- und Ereignismanager des Browserportals einsehen und Alarmbearbeitungen (Annehmen, Quittieren, St\'F6rmeldeunterdr\'FCckung) vornehmen.\par
\plain\fs20 Der Alarm- und Ereignismanager verf\'FCgt \'FCber ein Tab-Men\'FC \'FCber das verschiedene Meldungslisten aufgerufen werden k\'F6nnen. Im Standard sind das eine Gesamtliste, die alle Meldungen unabh\'E4ngig von deren Kategorisierung enth\'E4lt, sowie eine Alarm-, eine Warnungs- und eine Meldungsliste, die jeweils nur Meldungen der entsprechenden Meldungskategorie vorhalten. Jede Meldung ist mit allen notwendigen Informationen in den Meldungslisten anzuzeigen, so dass eine ausreichende Bewertung der Meldung und deren Bearbeitung m\'F6glich ist. Diese sind mindestens: Ereignisart (Kategorie), Datum/Zeit-Stempel, Status, Priorit\'E4t, Bezeichnung, Benutzeradressschl\'FCssel/Anlagenkennschl\'FCssel (BAS/AKS), Bearbeiter, Datenpunkt-TAG, Objekt-Name (BACnet), Kommentar, Wert, Gruppe, Alarmseite, Handlungsanweisung, Event State (BACnet). Die Informationen m\'FCssen jeweils in eigenen Spalten angezeigt und je Benutzer individuell ein- und ausgeblendet, sowie beliebig angeordnet werden k\'F6nnen. Jede Meldungsliste muss es erlauben die Listeneintr\'E4ge nach einer beliebigen Spalte in auf- oder absteigender Anordnung neu zu sortieren.\par
\plain\fs20 Jede Meldungsliste muss es erlauben die Listeneintr\'E4ge nach einer beliebigen Spalte zu filtern. Abh\'E4ngig von der Spaltenart muss dies \'FCber Optionsfelder mit vordefinierten Filtereintr\'E4gen (z.B. bei der Spalte Ereignisart filterbar nach Alarmen, Warnungen oder Meldungen) oder \'FCber freie Textfilter erfolgen. Dabei m\'FCssen je Liste auch Filterungen \'FCber eine beliebige Anzahl von Spalten kombinierbar sein. \'DCber eine separate Schaltfl\'E4che m\'FCssen alle Filterungen je Liste unverz\'FCglich zur\'FCckgesetzt werden k\'F6nnen. Wurde eine individuelle Filterung vorgenommen muss es f\'FCr den Benutzer m\'F6glich sein diese in einer neuen Meldungsliste abzulegen. Dies ist im Besonderen sinnvoll und n\'F6tig um Meldungen z. B. in gewerke- oder anlagenbezogene Meldungslisten einsortieren zu k\'F6nnen und so die Meldungsbearbeitung zu vereinfachen und zu beschleunigen. \par
\plain\fs20 Wird eine Meldung in einer Meldungsliste angew\'E4hlt so ist der bisherige Meldungsverlauf der jeweiligen Meldung in einer separaten Verlaufsansicht anzuzeigen. Die Verlaufsansicht muss beliebig ein- und ausgeblendet werden k\'F6nnen und darf hierbei nicht in einem PopUp-Fenster dargestellt werden, sondern soll neben oder unter der Meldungsliste angeordnet sein, um schnell mit den Pfeiltasten einer Tastatur die Verl\'E4ufe mehrerer Meldungen einer Meldungsliste durchsehen zu k\'F6nnen. Die Verlaufsansicht bietet hierbei die identischen Eigenschaften wie die Meldungslisten hinsichtlich Spalteninformationen, Sortier- und Filterfunktionen. Zus\'E4tzlich muss es mittels Berechtigung m\'F6glich sein, Benutzern den Zugriff auf das Alarmlogbuch freizuschalten. Das Alarmlogbuch ist in diesem Fall \'FCber einen weiteren Reiter im Alarm- und Ereignismanager anw\'E4hlbar. Im Alarmlogbuch sind alle historischen Meldungsbearbeitungen dauerhaft durch die MBE-Software abzuspeichern, um diese zu einem sp\'E4teren Zeitpunkt auswerten und nachvollziehen zu k\'F6nnen. Das Logbuch bietet die identischen Eigenschaften wie die Meldungslisten hinsichtlich Spalteninformationen, Sortier- und Filterfunktionen.\par
\plain\fs20 Meldungsbearbeitungen m\'FCssen aus jeder Meldungsliste heraus m\'F6glich sein. Dabei m\'FCssen einzelne Alarme, alle Alarme der aktuellen Listenansicht oder alle Alarme einer Filterung bearbeitet werden k\'F6nnen. Die Meldungsbearbeitung sollte \'FCber einen PopUp-Dialog erfolgen. Je nach Benutzerberechtigung und aktueller Ereignisart der zu behandelnden Meldung m\'FCssen folgende Bearbeitungsm\'F6glichkeiten zur Verf\'FCgung stehen: Annehmen, Quittieren, St\'F6rungsunterdr\'FCckung, St\'F6rungsunterdr\'FCckung deaktivieren. Jede Meldungsbearbeitung muss zwingend vom Bediener mit einem Kommentar versehen werden. Andernfalls darf keine Meldungsbearbeitung zugelassen werden. Zu jedem Alarm muss eine Alarmseite verkn\'FCpft werden, um so aus der Alarmliste auf das zugeh\'F6rige Anlagenbild springen zu k\'F6nnen.\par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111852}Meldungsweiterleitung{\*\bkmkend _Toc31111852}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Das MBE-System muss es erm\'F6glichen, dass bei Verletzung von Alarmgrenzen oder Zustands\'E4nderungen von Datenpunkten Meldungen \'FCber verschiedene Kan\'E4le an unterschiedliche Empf\'E4ngergruppen oder einzelne Empf\'E4nger versendet werden. Im vorliegenden Projekt sind Meldungen via E-Mail und SMS an bis zu 10 Empf\'E4nger zu versenden. Alle hierzu ben\'F6tigen Hard- und Softwaremodule (z.B. GSM-Gateway, o.\'E4.) sowie Lizenzen sind im Angebot zu ber\'FCcksichtigen. Auch ist eine zus\'E4tzliche Alarmierung via Sprachanruf und die M\'F6glichkeit eine Quittierung via SMS durchzuf\'FChren anzubieten. \par
\plain\fs20 Als Meldungsdatenpunkt muss jeder vom MBE-System erfasste Datenpunkt, unabh\'E4ngig von unterlagertem System oder Typ, definiert und mit mindestens zwei individuellen Regeln zur Ereignisausl\'F6sung belegt werden k\'F6nnen. Ein Meldungsversand muss zudem unabh\'E4ngig von einer Zuordnung zum Alarm- und Ereignismanagement m\'F6glich sein. Je Meldungsdatenpunkt muss festgelegt werden k\'F6nnen, ob zus\'E4tzlich zur Ereignismeldung auch eine Gutmeldung versendet werden soll. Vom Projektierer der MBE sind mindestens alle betriebsrelevanten Datenpunkte dem Alarm- und Ereignismanagement, sowie der Meldungsweiterleitung zuzuordnen und entsprechend zu konfigurieren. Im Detail sind die Datenpunkte f\'FCr das Alarm- und Ereignismanagement sowie die Meldungsweiterleitung mit dem Planer und dem Betreiber zu Projektbeginn abzustimmen. \par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111853}Energie-Management{\*\bkmkend _Toc31111853}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Die MBE-Software muss \'FCber ein integriertes Energiemanagementsystem (im Weiteren EnMS) verf\'FCgen. Das EnMS gibt dem Bediener die M\'F6glichkeit Energieverbrauchsdaten aufzuzeichnen, zu dokumentieren und auszuwerten. Hierzu muss das EnMS \'FCber Module f\'FCr die Verbrauchsauswertung, die Messwertverwaltung, eine manuelle Messwerterfassung, ein Reportarchiv sowie das automatisierte Reporting verf\'FCgen. Diese werden nachfolgend n\'E4her beschrieben. Optional muss es m\'F6glich sein Energieverbr\'E4uche witterungsbereinigt auszuwerten. Die Witterungsbereinigung hat dabei auf Basis von Gradtagszahlen zu erfolgen, die vom Deutschen Wetterdienst (DWD) zur Verf\'FCgung gestellt werden.\par
\plain\fs20\'DCber die Berechtigungsvergabe der MBE-Software muss es zum einen m\'F6glich sein, je Benutzer die einzelnen Module des EnMS sowie zum anderen die Verbrauchsmesswerte individuell zur Verwendung im EnMS freizuschalten oder zu sperren. \par
\wpparflg32\plain\fs20 F\'FCr das EnMS m\'FCssen alle Datenpunkte mit fortlaufendem Verbrauchsmesswert, unabh\'E4ngig von der Datenquelle, der Einheit oder dem Medium, verwendet werden k\'F6nnen. Als m\'F6gliche Datenquellen zur Anbindung von Z\'E4hlersystemen m\'FCssen hierbei mindestens die Treiberschnittstellen der MBE-Software zur Verf\'FCgung stehen. Neben der Einbindung von Verbrauchsmesswerten von physikalischen Energie- und Verbrauchsz\'E4hlern, muss es ebenso m\'F6glich sein Verbrauchsmesswerte zu integrieren, die auf Automationsstationen angelegt sind oder die in der MBE-Software als virtuelle Datenpunkte zur Verf\'FCgung stehen. Die Speicherung der Verbrauchsmesswerte hat in der unter dem Punkt Trendauswertungen beschriebenen Microsoft SQL Datenbank zu erfolgen.\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111854}\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20 Verbrauchsauswertung{\*\bkmkend _Toc31111854}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32 :\par
\wpparflg32\plain\fs20 Zu jedem Zeitpunkt muss es f\'FCr autorisierte Benutzer m\'F6glich sein, entweder individuelle Verbrauchsauswertungen oder eine Auswertung durch Auswahl eines selbst erstellten Favoriten zu erzeugen. Hierzu muss eine Konfigurationsansicht zur Verf\'FCgung stehen, in der f\'FCr eine individuelle Auswertung die relevanten Messwertdatenpunkte ausgew\'E4hlt, die Ausgabedarstellung, sowie die Zeitbereichswahl vorgenommen werden k\'F6nnen. \par
\plain\fs20 In der Konfigurationsansicht m\'FCssen alle f\'FCr einen Benutzer freigeschalteten Verbrauchsmesswerte in einer Messwerttabelle zur Verf\'FCgung stehen. Um schnell die passenden Verbrauchsmesswerte f\'FCr eine Auswertung finden zu k\'F6nnen, muss es m\'F6glich sein, die Verbrauchsmesswerte zum einen nach dem Einbauort und zum anderen \'FCber einen beliebigen Suchtext in der Messwertbeschreibung zu filtern. Die Filterm\'F6glichkeiten m\'FCssen einzeln, aber auch kombiniert anwendbar sein. Der Auftraggeber erstellt eine Zuordnung von Verbrauchsmesswert und Einbauort. Diese Zuordnung ist vom Errichter der MBE ins System einzupflegen.   \par
\plain\fs20 F\'FCr jede Auswertung m\'FCssen mindestens acht Messwerte in der Messwerttabelle angew\'E4hlt werden k\'F6nnen. Dabei muss es m\'F6glich sein nur den Rohwert, nur den witterungsbereinigten Wert oder beide Werte eines Verbrauchsmesswertes in die Auswertung zu \'FCbernehmen. Zudem m\'FCssen alle Messwerte unabh\'E4ngig von Einheit oder Medium zu einer Auswertung zusammengestellt werden k\'F6nnen. \par
\plain\fs20 F\'FCr die Darstellung einer Auswertung stehen mindestens die folgenden Diagrammtypen zur Verf\'FCgung: Tabelle, S\'E4ulendiagramm, S\'E4ulendiagramm je Messwert, S\'E4ulendiagramm gestapelt, Kreisdiagramm. Die Darstellungsart ist \'FCber einen Auswahldialog anw\'E4hlbar. \par
\plain\fs20 Der Auswertezeitraum muss je Auswertung beliebig auf einen ausw\'E4hlbaren vorgegebenen Zeitraum (z.B. letzte 60 Minuten, letzte volle Stunde, letzter voller Tag, letzter Monat, letztes volles Jahr) oder einen benutzerdefinierten Zeitraum mit der Vorgabe von Datum und Uhrzeit f\'FCr Beginn und Ende der Auswertung einstellbar sein.\par
\plain\fs20 Bei einer g\'FCltigen Konfiguration kann die Auswertung \'FCber eine separate Schaltfl\'E4che erzeugt werden.\par
\plain\fs20 Es muss m\'F6glich sein, parallel mehrere Auswertungen zu \'F6ffnen. Hierzu ist die Verbrauchsauswertung in einem Tab-Men\'FC organisiert. Die Konfigurationsansicht ist stets \'FCber den ersten Tab (Registerkarte) zu jeder Zeit aufrufbar, um neue Auswertungen zu erzeugen. Jede neue Auswertung reit sich ans Ende der Tab-Reihe als neuer Tab (Registerkarte) ein.     \par
\plain\fs20 Zus\'E4tzlich zu einer individuellen Auswertungskonfiguration muss es m\'F6glich sein, \'FCber einen Auswahldialog, einen zuvor erstellen Favorit aufzurufen. Mit Anwahl eines Favoriten m\'FCssen die hinterlegten Konfigurationen des Favoriteneintrags geladen werden und die Auswertung muss erzeugt werden k\'F6nnen. Die Favoriten-Konfiguration muss f\'FCr eine einmalige Auswertung beliebig \'E4nderbar sein, ohne dass diese \'C4nderungen im Favorit gespeichert werden. \par
\plain\fs20 Ein neuer Favorit muss aus einer erzeugten Auswertung oder \'FCber ein separates Favoritenmen\'FC erstellt werden k\'F6nnen. Neben der Festlegung der Auswertekonfiguration muss f\'FCr jeden Favoriten ein individueller Name vergeben, sowie die Schutzstufe des Favoriten (privat oder \'F6ffentlich) definiert werden k\'F6nnen. \'D6ffentliche Favoriten m\'FCssen dabei von jedem Benutzer, der Zugriff auf die Verbrauchsauswertung hat, zur Auswertung ausgew\'E4hlt werden k\'F6nnen. Private Favoriten sind nur f\'FCr den Ersteller sichtbar. Bestehende Favoriten m\'FCssen \'FCber das Favoritenmen\'FC bearbeitet, dupliziert oder gel\'F6scht werden k\'F6nnen.\par
\plain\fs20 Jede Verbrauchsauswertung stellt das ausgew\'E4hlte Diagramm und, abh\'E4ngig von der gew\'E4hlten Darstellungsart, alle historisierten Werte des ausgew\'E4hlten Zeitraums in tabellarischer Form dar. Eine Legende mit den in der Auswertung verwendeten Messwerten muss ein- und ausblendbar sein. Es muss m\'F6glich sein, einen oder mehrere Messwerte aus dem Diagramm aus- und erneut einzublenden. Aus jeder Auswertung heraus muss ein Export in einen Report im PDF- und XLSX-Format m\'F6glich sein. Zudem muss jede Auswertung zentral auf dem MBE Server speicherbar sein. Ein Report der auf dem Server abgelegt wird muss mindestens mit einer Bezeichnung versehen werden und zus\'E4tzlich die M\'F6glichkeit bieten einen Kommentar zu hinterlegen. Dar\'FCber hinaus muss der Benutzer die Schutzstufe des Reports (privat oder \'F6ffentlich) festlegen k\'F6nnen. \par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111855}Reportarchiv{\*\bkmkend _Toc31111855}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32 :\par
\wpparflg32\plain\fs20 Auf dem MBE Server gespeicherte Reports m\'FCssen zu jeder Zeit f\'FCr autorisierte Benutzer im Reportarchiv einsehbar sein. Jeder Benutzer muss Zugriff auf seine erstellten und mit privat deklarierten Reports, sowie auf die Reports aller Benutzer, die als \'F6ffentlich deklariert wurden, erhalten. Die Reports sind in tabellarischer Form darzustellen. Jeder Tabelleneintrag ist dabei mit mindestens folgenden Informationen darzustellen: Beschreibung, Erstelldatum, Betrachtungszeitraum, Darstellung (z.B. Monatswerte, Tageswerte, Stundenwerte, etc.), Ersteller, Schutzstufe (privat oder \'F6ffentlich). Die archivierten Reports m\'FCssen \'FCber das Start- und/oder das Enddatum des Betrachtungszeitraums, die Messwerte oder die Bezeichnung gefiltert werden k\'F6nnen.\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111856}Automatisierte Reports{\*\bkmkend _Toc31111856}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\wpparflg32\plain\fs20 Es muss m\'F6glich sein, automatisierte Reports einzurichten, die zyklisch an beliebige E-Mail Empf\'E4nger in Form eines PDF- oder XLSX-Reports oder in einer Listendarstellung im CSV-Format versendet werden. F\'FCr jeden automatisierten Report m\'FCssen die identischen Konfigurationsm\'F6glichkeiten, wie in der Verbrauchsauswertung beschrieben, zur Verf\'FCgung stehen. Zus\'E4tzlich ist eine Versendeh\'E4ufigkeit und die Uhrzeit des Report-Versands festzulegen. Die Versendeh\'E4ufigkeit sollte aus einer Auswahl von vordefinierten Eintr\'E4gen auszuw\'E4hlen sein, wie z. B.  T\'E4glich, montags, freitags, am ersten des Monats. F\'FCr jeden automatisierten Report sind abschlie\'DFend die Messwerte und die E-Mail-Empf\'E4nger einzurichten. Je Report m\'FCssen mindestens 8 Messwerte ausw\'E4hlbar sein. Die Anzahl der maximalen E-Mail-Empf\'E4nger je Report muss mindestens 12 betragen.\par
\wpparflg32\plain\fs20 Die maximale Anzahl an einzurichtenden automatisierten Reports darf nicht limitiert sein. Vom Errichter der MBE ist zu Projektbeginn ein Beispiel-Report einzurichten. Alle weiteren automatisierten Reports werden von den Mitarbeitern des Auftraggebers eingerichtet.\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111857}Manuelle Messwerterfassung{\*\bkmkend _Toc31111857}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32 :\par
\wpparflg32\plain\fs20 Um auch Verbrauchsz\'E4hler im EnMS erfassen und auswerten zu k\'F6nnen, die zum Zeitpunkt der Inbetriebnahme nicht \'FCber eine Protokollschnittstelle verf\'FCgen oder aus anderen Gr\'FCnden nicht an das System angebunden werden konnten, muss das EnMS die M\'F6glichkeit bieten manuelle Messstellen einzurichten. Jede manuelle Messtelle muss \'FCber eine Eingabemaske verf\'FCgen, die es erlaubt einen zuvor von der Messeinrichtung abgelesenen Verbrauchswerte mit Uhrzeit und Datum der Ablesung ins System einzugeben. In der Eingabemaske ist zus\'E4tzlich die Einheit, der Zeitpunkt und der Wert der letzten Ablesung anzuzeigen. Mit Eingabe eines neuen Verbrauchsmesswertes muss das System mindestens eine Validierung durchf\'FChren, ob der eingegebene Wert gleich oder gr\'F6\'DFer dem letzten Wert ist. Manuelle Messwerte m\'FCssen wie alle anderen Datenpunkte und Messwerte zur Verwendung in allen Modulen des Systems zur Verf\'FCgung stehen.\par
\pard\plain\wpparflg32\plain\fs20\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111858}Messwertverwaltung:{\*\bkmkend _Toc31111858}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\wpparflg32\plain\fs20 Das EnMS muss dem Benutzer in Abh\'E4ngigkeit seiner Berechtigung die M\'F6glichkeit bieten, die Eigenschaften eines Messwertes zu jeder Zeit zu bearbeiten. Diese Eigenschaften sind mindestens: Beschreibung, Einheit, Einbauort, Medium, Wertart, Historisierungstiefe. Wurde eine Eigenschaft ge\'E4ndert und abgespeichert, ist diese unmittelbar vom System zu \'FCbernehmen.\par
\wpparflg32\plain\fs20{\*\bkmkstart _Toc31111859}Zusammengesetzte Messwerte{\*\bkmkend _Toc31111859}\li0\fi0\ri0\sb0\sa0\ql\vertalt\wpparflg32\par
\wpparflg32\plain\fs20 Als weiteres muss das EnMS zusammengesetzte Messwerte unterst\'FCtzen. Ein zusammengesetzter Messwert ist ein virtueller Messwert, der sich aus einem oder mehreren Messwerten, mit diversen Rechenoperationen versehen, zusammensetzt. Je physikalischem und manuellem Messwert ist im System vom Errichter mindestens ein unkonfigurierter, zusammengesetzter Messwert anzulegen. Im System angelegte zusammengesetzte Messwerte m\'FCssen zu jeder Zeit von Benutzern mit entsprechender Berechtigung konfiguriert werden k\'F6nnen. Hierzu muss das EnMS einen einfach zu bedienenden Formeleditor zur Verf\'FCgung stellen. \par
\pard\plain\plain\fs20\par
\plain\fs20 Fernzugriff\par
\sa454\plain\fs20 F\'FCr den Fernzugriff auf das MBE System wird seitens des Auftraggebers ein VPN-Zugang auf dem MBE-Server eingerichtet. Hier\'FCber ist es f\'FCr Mitarbeiter des AG m\'F6glich auch von au\'DFerhalb des Unternehmensnetzwerks und von jedem Endger\'E4t mit einem HTML5-f\'E4higen Browser auf das MBE-System zuzugreifen.\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\wpparid0\plain\fs20\b\par
\wpparid0\plain\fs20\b Hardware / Virtuelle Maschine wird vom AG beigestellt\par
\pard\plain\wpparid0\plain\fs20\par
\plain\fs20 Das PC-System oder eine virtuelle Maschine zur Installation und Bedienung der Management- und Bedieneinrichtung B-CON, inklusive Monitor und Bedienset, wird vom AG beigestellt. Die Maschine wird dem vorliegenden Projektumfang und den Systemvoraussetzungen der Software B-CON vom AG entsprechend konfektioniert. Die Maschine wird vom AG mit einer lizensierten Version des Betriebssystems Microsoft Windows gem\'E4\'DF Freigabe der aktuellen B-CON Systemanforderungen ausgestattet. Die Maschine wird dem AN, ohne Bedienset und Monitor, zur Installation und Einrichtung mindestens 14 Werktage vor dem Inbetriebnahmetermin zu Lasten des AG per Post/Paketdienst zugestellt oder es ist eine Ferneinwahlm\'F6glichkeit zur Verf\'FCgung zu stellen.\par
\plain\fs20 Die vom AN vorkonfigurierte Maschine ist sp\'E4testens bis zum Inbetriebnahmetermin auf der Baustelle oder einem vom AG bekanntgegebenen Ort zu eigenen Lasten abzuliefern/mitzubringen bzw \'FCber die Ferne fertig einzurichten. Der AN hat f\'FCr einen entsprechend versicherten Versand/Lieferung Sorge zu tragen.\par
\pard\plain\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\wpparid0\plain\fs20\b\ul\par
\wpparid0\plain\fs20\b Hinweise zur Abgrenzung\ulnone  von Dienstleistungen und Inbetriebnahmeleistungen:\par
\pard\plain\wpparid0\plain\fs20\b\ul\par
\plain\fs20 Insofern nicht gesondert ausgewiesen, betreffen alle angebotenen Dienstleistungen und Inbetriebnahmeleistungen im vorliegenden Angebot ausschlie\'DFlich die Parametrierung, Einrichtung und Inbetriebnahme unserer Software B-CON sowie der von uns angebotenen und gelieferten Hardwarekomponenten.\par
\plain\fs20 Die Parametrierung oder Inbetriebnahme und speziell die Ert\'FCchtigung von Kommunikationsschnittstellen von Fremd- oder Drittanbieter-Systemen ist kein Bestandteil dieses Angebotes und wird als bauseitige Vorleistung vorausgesetzt. \par
\pard\plain\wpparid0\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\plain\fs20\par
\plain\fs20\b Hinweise zur Anbindung von Automationsstationen und Systemen mit \ul BACnet\ulnone -Schnittstelle:\par
\pard\plain\plain\fs20\par
\plain\fs20 Anzubindenden BACnet-Ger\'E4te m\'FCssen \'FCber eine BACnet/IP-Schnittstelle verf\'FCgen und alle f\'FCr die B-CON MBE relevanten Datenpunkte als BACnet-Objekte zur Verf\'FCgung stellen.\par
\plain\fs20 Es sind nur Systeme zugelassen, die mindestens die Einstellung einer projektspezifischen IP-Adresse und einer projektspezifischen BACnet-Device-ID zulassen.\par
\plain\fs20 Die Einstellung des\'A0BACnet-Ports ist nur n\'F6tig, wenn diese\'A0vom BACnet-Standardport "47808" abweicht oder projektspezifisch abweichende Porteinstellungen gefordert sind.\par
\plain\fs20\'A0\par
\plain\fs20 Eine BACnet-konforme Projektierung und Programmierung der anzubindenden BACnet-Ger\'E4te wird vorausgesetzt. Eine Kommunikation mit propriet\'E4ren BACnet-Objekte oder propriet\'E4ren BACnet-Properties, die nicht im BACnet-Standard aufgef\'FChrt sind, wird nicht unterst\'FCtzt. Die anzubindenden BACnet-Ger\'E4te sollten eine BACnet-konforme Projektierung bez\'FCglich dem BACnet-Alarming (NotificationClasses), Scheduling (Scheduler), und Trending (Trendlogs) aufweisen. Je Netzwerksegement ist genau ein BBMD (BACnet Broadcast Management Device)\'A0einzurichten. Bei der Auswahl dieses ist darauf zu achten, dass das BBMD die Kommunikation \'FCber foreign Devices unterst\'FCtzt.\par
\plain\fs20\'A0\par
\plain\fs20 Mindestens folgende Informationen werden je BACnet Ger\'E4t ben\'F6tigt:\par
\plain\fs20 BACnet Device ID\par
\plain\fs20 IP Adresse des BACnet Ger\'E4tes\par
\plain\fs20\'A0\par
\plain\fs20 Mindestens folgende BACnet-Objekt-Eigenschaften (Properties) sind entsprechend ihrer Funktion sinnvoll und vollst\'E4ndig zu bef\'FCllen:\par
\plain\fs20 BACnet-ObjectNames\par
\plain\fs20 BACnet-Descriptions\par
\plain\fs20 BACnet-Units\par
\plain\fs20 BACnet-Limits (High- + LowLimit)\par
\plain\fs20 BACnet-Deadbands\par
\plain\fs20 BACnet-AlarmValues\par
\plain\fs20 BACnet-Messagetexts\par
\plain\fs20 BACnet-ActiveTexts\par
\plain\fs20 BACnet-InactiveTexts\par
\plain\fs20 BACnet-StateTexts\par
\plain\fs20 BACnet-Statusflags\par
\plain\fs20 BACnet-COVIncrement\par
\plain\fs20 BACnet-PriorityArray: Priorit\'E4t Automationsebene = 16, Priorit\'E4t GLT = 8\par
\plain\fs20\'A0\par
\plain\fs20 Der Errichter der BACnet-Automationsstation (BACnet-AS) hat dem Auftragnehmer der MBE je anzubindendem BACnet-Ger\'E4t eine BACnet-EDE-Datei zu \'FCbergeben. Die BACnet-EDE-Datei ist vom Errichter der BACnet-AS auf die f\'FCr das Management-System relevanten BACnet-Objekte zu bereinigen. Der BACnet-seitige Projektierungsstand der anzubindenden BACnet-Ger\'E4te muss zum Zeitpunkt der Inbetriebnahme der B-CON mit dem der \'FCbergebenen EDE-Datei \'FCbereinstimmen.\par
\plain\fs20 Der Errichter unterlagerter Anlagentechnik stellt je anzubindender Anlage ein Anlagenschema mit verorteten Datenpunkten zur Verf\'FCgung.\par
\plain\fs20\'A0\par
\plain\fs20 Die Kommunikation sowie die Validierung der Objekte nebst allen Properties zwischen Ger\'E4t und einem unabh\'E4ngigen BACnet Client muss vom Errichter gepr\'FCft und nachgewiesen sein.\par
\pard\plain\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\plain\fs20\par
\plain\fs20\b Hinweise zur Anbindung von Ger\'E4ten und Systemen mit \ul KNX\ulnone -Schnittstelle:\par
\pard\plain\plain\fs20\par
\plain\fs20 Anzubindenden KNX-Ger\'E4te m\'FCssen \'FCber eine im KNX-Netzwerk integrierte KNX/IP- oder KNX-USB-Schnittstelle verf\'FCgen. Eine KNX-USB-Schnittstellle kann nur verwendet werden, wenn diese in unmittelbarer N\'E4he zum B-CON Server installiert wird und der B-CON Server \'FCber eine freie USB-Schnittstelle verf\'FCgt.\'A0Ein KNX IP Router\'A0ist zu bevorzugen.\par
\plain\fs20 Es sind nur Systeme zugelassen, die mindestens die Einstellung einer projektspezifischen IP-Adresse und Multicast-Adresse zulassen.\par
\plain\fs20 Die Einstellung des Netzwerk-Ports ist nur n\'F6tig, wenn die Port-Einstellung vom KNX-Standardport "3671" abweicht oder projektspezifisch abweichende Porteinstellungen gefordert sind.\par
\plain\fs20\'A0\par
\plain\fs20 KNX-Projekte sind grunds\'E4tzlich nach den Vorgaben der aktuellsten Fassung der KNX Projektrichtlinien (KNX Project Design Guidelines), die von der KNX Association herausgegeben werden, zu erstellen.\par
\plain\fs20 Dar\'FCber hinaus ist\'A0es\'A0zwingend erforderlich, dass\'A0der Datentyp\'A0(DPT)\'A0bei allen relevanten Gruppenadressen korrekt eingerichtet ist.\par
\plain\fs20\'A0\par
\plain\fs20 Der Errichter des KNX-Systems hat ICONAG nach Abschluss der Programmierung eine ETS-Export-Datei im Format\'A0.ESF, einen Export aller Gruppenadressen im\'A0Format .CSV\'A0und zus\'E4tzlich das KNX Projekt als Export File (.knxproj)\'A0zu \'FCbergeben.\par
\plain\fs20 Die Export-Dateien (.ESF und .CSV) sind vom Errichter des KNX-Systems auf die f\'FCr das Management-System relevanten Gruppenadressen zu bereinigen. Der Errichter des KNX-Systems stellt je KNX-System ein Anlagenschema/Grundrissplan mit verorteten Gruppenadressen zur Verf\'FCgung.\par
\plain\fs20\'A0\par
\plain\fs20 Die Kommunikation zu allen Datenpunkten ist mittels einer Aufzeichnung des in der ETS implementierten Gruppenadressmonitors nachzuweisen. Bei allen Datenpunkten die nach einem Systemstart unmittelbar relevant sind, ist in einem geeigneten Ger\'E4t das Lesen-Flag zu setzen.\par
\pard\plain\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\wpparid0\plain\fs20\b\ul\par
\wpparid0\plain\fs20\b Hinweise zur Anbindung von Automationsstationen und Systemen mit \ul Modbus\ulnone -Schnittstelle:\par
\pard\plain\wpparid0\plain\fs20\b\ul\par
\wpparid0\plain\fs20 Ger\'E4te mit Modbus-Schnittstelle werden ausschlie\'DFlich \'FCber Modbus TCP/IP an das B-CON System angebunden.\par
\wpparid0\plain\fs20 Ger\'E4te mit Modbus RTU-Schnittstellen sind zun\'E4chst bauseits mittels SPS-Kopftstation oder Gateway auf Modbus TCP/IP umzusetzen.\par
\wpparid0\plain\fs20 Kommt ein Gateway zum Einsatz kann ICONAG nur in Verbindung mit dem von uns freigegebenen Produkt Moxa MGate MB3170 eine einwandfreie Funktion garantieren.\par
\pard\plain\wpparid0\plain\fs20\par
\wpparid0\plain\fs20 Der Auftraggeber stellt je anzubindender Anlage ein Anlagenschema mit verorteten Datenpunkten, sowie eine vollst\'E4ndige Datenpunktliste mit folgenden Angaben je Datenpunkt zur Verf\'FCgung: \par
\ls24\ilvl0{\listtext\f6\fs20 \'B7\tab}\li360\fi-360\wpparid0\plain\fs20 Datenpunktname, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Klartextbezeichnung, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Anlagenzuordnung, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Byte order\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Word order\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Unit ID\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Modbus-Adresse (dezimal, mit bereits eingerechneten Offsets) \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Object Type / Function Code\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Data Type / Quantity\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Bit Position\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Alarmlogik (bei Bin\'E4ren St\'F6rmeldedatenpunkten),\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Alarmgrenzen (bei numerischen Datenpunkten),\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Skalierung, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Einheit.\par
\pard\plain\wpparid0\plain\fs20\par
\wpparid0\plain\fs20 Bei Steuerungen die mit Codesys 2.x programmiert werden ist zus\'E4tzlich der Export der Symbolkonfiguration (*.SYM) zu \'FCbergeben. Bei WAGO-Steuerungen die mit e!Cockpit programmiert werden, ist zus\'E4tzlich der CSV-Export aus der Modbus-Konfiguration zu \'FCbergeben.\par
\pard\plain\wpparid0\plain\fs20\par
\plain\fs20 Die Datenpunktliste oder die \'FCbergebene Konfigurationsdatei ist vom Errichter derart zu bearbeiten, dass in dieser ausschlie\'DFlich die f\'FCr das Management System relevanten Datenpunkte enthalten sind. Grunds\'E4tzlich werden alle Datenpunkte die in der Datenpunktliste oder der \'FCbergebenen Konfigurationsdatei enthalten sind mit allen Konsequenzen im Management System angelegt und abgerechnet.\par
\plain\fs20\'A0\par
\plain\fs20 Die Kommunikation sowie die Validierung der Werte zwischen Ger\'E4t und einem unabh\'E4ngigen Modbus TCP Client muss vom Errichter gepr\'FCft und nachgewiesen sein.\par
\pard\plain\wpparid0\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\page\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\wpparid0\plain\fs20\b\ul\par
\wpparid0\plain\fs20\b Hinweise zur Anbindung von Ger\'E4ten und Systemen mit \ul Profibus\ulnone -Schnittstelle:\par
\pard\plain\wpparid0\plain\fs20\b\ul\par
\wpparid0\plain\fs20 Eine direkte Anbindung eines Profibus-Netzwerkes an den B-CON Server erfolgt nicht. Die Anbindung von Profibus-Systemen an das B-CON System erfolgt via Ethernet mittels einer oder mehrerer S5/7-Kopfstationen. Diese werden vom Auftraggeber zur Verf\'FCgung gestellt, betriebsfertig parametriert, eingerichtet und sind \'FCber das bauseits vorhandene IP-Netzwerk vom B-CON Server zu erreichen.\par
\wpparid0\plain\fs20 Die S7-Projektdatei mit allen f\'FCr das B-CON-System relevanten Datenpunkten ist an ICONAG f\'FCr den Import im Kommunikationstreiber zu \'FCbergeben. \par
\pard\plain\wpparid0\plain\fs20\par
\wpparid0\plain\fs20 Der Auftraggeber stellt je anzubindender Anlage ein Anlagenschema mit verorteten Datenpunkten, sowie eine vollst\'E4ndige Datenpunktliste mit folgenden Angaben je Datenpunkt zur Verf\'FCgung: \par
\ls25\ilvl0{\listtext\f6\fs20 \'B7\tab}\li360\fi-360\wpparid0\plain\fs20 Datenpunktname, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Klartextbezeichnung, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Anlagenzuordnung, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Alarmlogik (bei Bin\'E4ren St\'F6rmeldedatenpunkten),\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Alarmgrenzen (bei numerischen Datenpunkten),\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Skalierung, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Einheit.\par
\pard\plain\wpparid0\plain\fs20\par
\sa454\wpparid0\plain\fs20 --------------------------------------------------------------------------------------- \par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\plain\fs20\par
\plain\fs20\b Hinweise zur Anbindung von Automationsstationen und Systemen mit \ul OPC UA\ulnone -Schnittstelle:\par
\pard\plain\plain\fs20\par
\plain\fs20 Alle f\'FCr das B-CON-System relevanten Datenpunkte sind auf den Automationsstationen als OPC UA-Datenpunkte zur Verf\'FCgung zu stellen.\par
\plain\fs20 Die Automationsstationen m\'FCssen im Netzwerk des B-CON Servers erreichbar sein und die OPC UA-Struktur mit allen Komponenten und Objekten von einem OPC UA-Client auslesbar sein.\par
\pard\plain\plain\fs20\par
\wpparid0\plain\fs20 Der Auftraggeber stellt je anzubindender Anlage ein Anlagenschema mit verorteten Datenpunkten, sowie eine vollst\'E4ndige Datenpunktliste mit folgenden Angaben je Datenpunkt zur Verf\'FCgung: \par
\ls26\ilvl0{\listtext\f6\fs20 \'B7\tab}\li360\fi-360\wpparid0\plain\fs20 Datenpunktname, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Klartextbezeichnung, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Anlagenzuordnung, \par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Object Type\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Alarmlogik (bei Bin\'E4ren St\'F6rmeldedatenpunkten),\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Alarmgrenzen (bei numerischen Datenpunkten),\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Skalierung\par
{\listtext\f6\fs20 \'B7\tab}\wpparid0\plain\fs20 Einheit\par
\pard\plain\wpparid0\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\plain\fs20\par
\plain\fs20\b Hinweise zur Anbindung von Automationsstationen und Systemen mit \ul LON\ulnone -Schnittstelle:\par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20 Es erfolgt auschlie\'DFlich eine Aufschaltung von Standard-SNVTs. Durch ICONAG erfolgt keine Einrichtung von Datenpunkt-"Bindings". Das Auslesen der LON-Datenpunkte erfolgt durch "Polling". Voraussetzung ist, dass ein Polling m\'F6glich ist. Falls nicht, muss unsere Treiberschnittstelle vom bauseitigen LON-Integrator im Netzwerk "gebindet" werden. Maximal k\'F6nnen zwei Dom\'E4nen angebunden werden. Bis insgesamt max. 2000 Datenpunkte je LON-Netzwerk (2 Dom\'E4nen).\par
\wpparflg32\plain\fs20 F\'FCr die Einrichtung von Management- und Bedienfunktionen ist durch den AG im Anschluss eine Zuordnung der Datenpunkte zu den gew\'FCnschten Managementfunktionen, sowie Anlagenschemata mit verorteten Datenpunkten zur Projektierung von Anlagenbildern zu erstellen.\par
\pard\plain\wpparid0\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\plain\fs20\b\par
\plain\fs20\b BACnet-Projektierung Management- und Bedieneinrichtung\par
\pard\plain\plain\fs20\b\par
\plain\fs20 Die Software f\'FCr die Management- und Bedieneinrichtung muss mindestens folgende BACnet-Funktionen unterst\'FCtzen, um die typischen Funktionen und Eigenschaften des BACnet-Protokolls optimal auf der Management-Ebene abzubilden:\par
\pard\plain\plain\fs20\par
\plain\fs20 Das BACnet-Ger\'E4teprofil B-OWS wird unetrst\'FCtzt.\par
\plain\fs20 F\'FCr die Erstellung der Anlagenbilder muss eine fertige Bibliothek mit BACnet-Controls zur Verf\'FCgung stehen.\par
\plain\fs20 Es m\'FCssen Controls mindestens f\'FCr folgende BACnet-Objekte hierin enthalten sein:\par
\plain\fs20 Analog-Objekt (Input, Output, Value), Binary-Objekt (Input, Output, Value), Multistate-Objekt (Input, Output, Value), Device-Objekt, Scheduler-Objekt, Loop-Objekt.\par
\pard\plain\plain\fs20\par
\wpparflg32\plain\fs20 Die Binary, Analog und Multistate Controls m\'FCssen vom grunds\'E4tzlichen Aufbau her identisch sein.\par
\plain\fs20 Jedes Control muss aus einem numerischen (Analog Control) bzw. einem String-Anzeigeelement (Binary, Multistate) zur Anzeige des Present-Value bestehen. Linksseitig davon befindet sich jeweils ein Anzeigeelement in dem die aktive Priority (bei vorhandenem Priority-Array) angezeigt wird. F\'FCr die Priority \u8222 ?16\u8220 ? wird ein A-Symbol, f\'FCr die Priority \u8222 ?8\u8220 ? ein Hand-Symbol angezeigt. Alle \'FCbrigen Priorities werden durch ein rotes Ausrufezeichen-Symbol dargestellt. Projektspezifisch m\'FCssen die Symbole der einzelnen Priorities austauschbat sein. Unterhalb der Anzeigeelemente von Present-Value und Priority-Array befindet sich die Status-Flag-Anzeige. \'DCber vier Symbole (inAlarm, Fault, Overridden, Out-of-Service) muss die Aktivit\'E4t der Status-Flags angezeigt.\par
\plain\fs20 Befindet sich ein BACnet-Objekt im Alarmzustand muss dies einerseits \'FCber ein rot leuchtendes Glockensymbol in der Status-Flag-Anzeige sowie \'FCber einen roten Rahmen um das Control signalisiert werden k\'F6nnen. Beim Analog-Control muss der Alarmrahmen zus\'E4tzlich durch ein blaues \u8222 ?LL\u8220 ? (Low-Limit) oder rotes \u8222 ?HL\u8220 ? (High-Limit) bei einer entsprechenden Grenzverletzung unterbrochen werden. Jeder Controltyp muss zus\'E4tzlich in einer \u8222 ?Simple\u8220 ?-Version verf\'FCgbar sein. Die \u8222 ?Simple\u8220 ?-Version unterscheidet sich hierbei lediglich durch das Weglassen der Status-Flag-Anzeige. Die \'FCbrigen Funktionalit\'E4ten bleiben davon unber\'FChrt.\par
\pard\plain\wpparid0\plain\fs20\par
\wpparid0\plain\fs20 Durch einen rechten Mausklick auf ein Control muss sich das dazugeh\'F6rige \u8222 ?BACnet-Objekt Eigenschaften\u8220 ?-Men\'FC \'F6ffnen.\par
\wpparid0\plain\fs20 Abh\'E4ngig vom Objekt-Typ erlangt der Bediener \'FCber das \u8222 ?BACnet-Objekt Eigenschaften\u8220 ?-Men\'FC Zugriff auf die wichtigsten Properties.\par
\wpparid0\plain\fs20 Diese sind u.a.: Object-Name, -Description, -Type, Instance-Number, Event-State, Relinquish Default, Priority, Priority-Array, Present Value, Status-Flags, Limits, Alarm-Value, States, State-Texts.\par
\wpparid0\plain\fs20\'DCber das \u8222 ?BACnet-Objekt Eigenschaften\u8220 ?-Men\'FC muss die Property Present-Value beschrieben werden k\'F6nnen. Das Zur\'FCcksetzen eines Wertes muss durch das Schreiben von "Null" m\'F6glich sein. Bei vorhandenem Priority-Array ist die Standard-Schreibpriorit\'E4t "8" eingestellt. \par
\wpparid0\plain\fs20 Die Schreibpriorit\'E4t muss \'FCber das \u8222 ?BACnet-Objekt Eigenschaften\u8220 ?-Men\'FC individuell \'E4nderbar sein.\par
\wpparid0\plain\fs20 Die Eigenschaft "Out-Of-Service" muss gesetzt werden k\'F6nnen.\par
\wpparid0\plain\fs20 Bei Analog-Objekten m\'FCssen zus\'E4tzlich die Properties High- und Low-Limit aktiv/deaktiv sowie die Grenzen einstellbar sein.\par
\wpparid0\plain\fs20 Bei Binary- und Multistate-Objekten ist zus\'E4tzlich das Property Alarm-Value \'E4nderbar.\par
\pard\plain\wpparid0\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\plain\fs20\par
\plain\fs20\b Hinweise zur Anbindung von Automationsstationen und Systemen im Bestand\ulnone :\par
\pard\plain\plain\fs20\par
\plain\fs20 Automationsstationen \'E4lterer Produkt-Generationen sind zwingend im Voraus bauseits auf eine Kommunikationsschnittstelle BACnet/IP, KNX/IP oder Modbus TCP zu ert\'FCchtigen, um auf das B-CON-System aufgeschaltet werden zu k\'F6nnen.\par
\plain\fs20 Eine Aufschaltung mittels eines anderen Busprotokolls wird nicht unterst\'FCtzt.\par
\plain\fs20 Alternativ kann bauseits ein passender OPC DA-Server (2.0 oder 3.0) beigestellt und funktionsfertig auf dem MBE-Server zur Verf\'FCgung gestellt werden.  \par
\pard\plain\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\plain\fs20\par
\plain\fs20\b Hinweise zur Anbindung von Automationsstationen und Systemen im Bestand\ulnone :\par
\pard\plain\plain\fs20\par
\plain\fs20 Automationsstationen \'E4lterer Produkt-Generationen (hier z.B. Priva Compri HX-Reihe, u.a.) sind zwingend im Voraus bauseits auf eine Kommunikationsschnittstelle BACnet/IP oder Modbus TCP zu ert\'FCchtigen, um auf das B-CON-System aufgeschaltet werden zu k\'F6nnen.\par
\plain\fs20 Eine Aufschaltung mittels eines anderen Busprotokolls wird nicht unterst\'FCtzt.\par
\plain\fs20 Alternativ kann bauseits ein passender OPC DA-Server (2.0 oder 3.0) beigestellt und funktionsfertig auf dem MBE-Server zur Verf\'FCgung gestellt werden.  \par
\pard\plain\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\wpparid0\plain\fs20\b\par
\wpparid0\plain\fs20\b Kommunikationstest\par
\pard\plain\wpparid0\plain\fs20\par
\wpparid0\plain\fs20 Der ordnungsgem\'E4\'DFe Zugriff auf die funktionsbereite Kommunikationsschnittstelle (M-Bus, Modbus, KNX oder BACnet) ist nach Fertigstellung vom jeweiligen Anlagenerrichter im IP-Netzwerk anhand eines Kommunikationstests zu pr\'FCfen und zu protokollieren.\par
\pard\plain\wpparid0\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\plain\fs20\par
\plain\fs20\b Projektierung HTML5-Analgenbilder\par
\pard\plain\plain\fs20\par
\plain\fs20 Die Anlagenbilder der Management- und Bedieneinrichtung sind durchg\'E4ngig mit den B-CON Webcontrols zu erstellen. Hierdurch wird gew\'E4hrleistet, dass der Benutzerzugriff auf die Management- und Bedieneinrichtung von jedem Endger\'E4t im Netzwerk des B-CON Servers mit einem HTML5-f\'E4higem Webbrowser erfolgen kann, ohne dass auf diesen Systemen eine Installation von weiterer Software notwendig ist. Eine weitere wesentliche Anforderung ist, dass das Browserportal auf HTML5-Technologie basiert und ohne zus\'E4tzliche Browser-Plugins (Java, Silverlight, etc.) auskommt. \par
\pard\plain\plain\fs20\par
\sa454\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\plain\fs20\b Bezugsnachweis:\par
\ri1984\wpparflg32\plain\fs20 ICONAG-Leittechnik GmbH\par
\plain\fs20 Hauptstra\'DFe 189\par
\plain\fs20 D-55743 Idar-Oberstein\par
\wpparflg32\plain\fs20 Tel.: +49-(0)6781-56234-0\par
\wpparflg32\plain\fs20 Fax: +49-(0)6781-56990-39\par
\plain\fs20 info@iconag.com\par
\sa454\wpparflg32\plain\fs20 www.iconag.com\par
\sect}\sectd\ltrsect\sbkpage\marglsxn1134\margrsxn567\margtsxn1134\margbsxn1134\headery1134\footery1134\sectdefaultcl{{\header{\ri0\sa113\wpparflg32\plain\f0\fs20\b ICONAG-Leittechnik GmbH\par
\tx1701\wpparflg32\plain\f0\fs20 Projekt:\tab  \par
\tx1701\wpparflg32\plain\f0\fs20 LV-Bezeichnung:\tab B-CON Management- und Bedieneinrichtung\par
\pard\brdrt\brdrs\brdrw15\brdrb\brdrs\brdrw15\sb113\sa113\sl288\slmult1\tx1701\tqr\tx8164\tqr\tx10148\vertalc\plain\fs20 OZ\tab Menge   Einheit\tab Einheitspreis EUR\tab Gesamtbetrag EUR\par
\pard\plain\par
}}
{\footer{\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth2\clwWidth2500\clvertalt\cellx5086\clftsWidth2\clwWidth2500\clvertalt\cellx10172\pard\intbl\plain\s36\li0\fi0\ri0\sb0\sa0\ql\f2\fs18 LV-Datum: \cell\pard\intbl\plain\s37\li0\fi0\ri0\sb0\sa0\qr\f2\fs18 Seite {\field{\*\fldinst{PAGE}}{\*\fldrslt{217}}}\cell\row}\tblend1}}
\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01\tab\f0\b Software\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.01\tab\f0\b B-CON Creative Studio\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.01.0010\tab\f0\b B-CON Creative Studio Editor (Abonnement)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 B-CON Creative Studio Editor\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 (Abonnement)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Lizenz zum Erstellen von Management- und\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Bedieneinrichtungen f\'FCr das technische\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Geb\'E4udemanagement (Geb\'E4udeleittechnik-\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 und Visualisierungsprojekte). Die\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Editorlizenz hat keinerlei\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Einschr\'E4nkungen in Bezug auf die Anzahl\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 der zu erstellenden \'DCbersichtsbilder,\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Anlagenbilder und Detailbilder oder die\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Anzahl der einzubindenden Datenpunkte\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 bzw. -objekte. Im Editor enthalten sind\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 folgende leistungsf\'E4hige Programm-\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Module:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Grafik-Editor zum Erstellen von\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'DCbersichtsbildern, Anlagenbildern und\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Detailbildern zum Beobachten und\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Bedienen inkl. einer umfangreichen MSR-\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 und Elektro-Symbolbibliothek f\'FCr\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 dynamische Einblendungen von mehr als\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 650 Symbolen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Alarmhandler zum Ereignis- und\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Alarmmanagement\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Messagehandler zum Versand von\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Nachrichten an externe Stellen per E-\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Mail\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Zeitschaltuhr f\'FCr zeitabh\'E4ngiges\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Schalten sowie zum Zeitplanmanagement\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Historie zum Trendmanagement\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Detektiv zur Schnellsuche und\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'C4nderung von Schalt- und Stellgr\'F6\'DFen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 sowie zum Berichtsmanagement\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Mini-Applet zum Anzeigen und\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Bedienen \'FCber eine Applikation in der\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 PC-Task-Leiste (Tray-Tool)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die B-CON Editor Jahreslizenz verl\'E4ngert\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 sich automatisch um ein weiteres Jahr,\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 sofern Sie die Lizenz nicht beim ICONAG-\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Vertriebsteam 3 Monate vor Ablaufdatum\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 schriftlich k\'FCndigen. Bitte wenden Sie\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 sich hierzu an das ICONAG-Vertriebsteam.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Preisgleitklausel: F\'FCr diesen Laufzeitvertrag gilt eine Preisgleitklausel. Die Preisanpassung erfolgt kalenderj\'E4hrlich jeweils zum 1. Januar in H\'F6he der Preisentwicklung der Erzeugerpreise f\'FCr Dienstleistungen in Deutschland. Grundlage der Preisanpassung ist der Prozentsatz, der vom Statistischen Bundesamt f\'FCr das 3. Quartal des Vorjahres festgestellt wurde. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Preis f\'FCr einj\'E4hrige Laufzeit (12 Monate)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hersteller: ICONAG\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Typ: B-CON Editorlizenz Creative Studio (Abo)\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.01\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Creative Studio\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.02\tab\f0\b B-CON Projekt-Runtimelizenzen f\'FCr OPC-DA, Modbus und KNX\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.02.0010\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 250 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Objekteditor\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Zeitschaltuhr\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Berechtigungsvergabe\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Alarmhandler\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Historienmodul\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Detektiv\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Quickfinder\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Webserver\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - ICONAG KNX OPC-Server\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - ICONAG Modbus2B-CON\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hersteller: ICONAG\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Typ: B-CON Runtime-Projektlizenz 250\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0020\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 500 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 500\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0030\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 1.500 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 1.500\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0040\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 3.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 3.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0050\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 5.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 5.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0060\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 10.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 10.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0070\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 12.500 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 12.500\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0080\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 15.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 15.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0090\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 17.500 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 17.500\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0100\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 20.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 20.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0110\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 25.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 25.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0120\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 30.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 30.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0130\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 35.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 35.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0140\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 40.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 40.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0150\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 45.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 45.000\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.02.0160\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 50.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG KNX OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - ICONAG Modbus2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz 50.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.02\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projekt-Runtimelizenzen f\'FCr OPC-DA, Modbus und KNX\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.03\tab\f0\b B-CON Projekt-Runtimelizenzen f\'FCr BACnet\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.03.0010\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 100 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Objekteditor\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Zeitschaltuhr\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Berechtigungsvergabe\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Alarmhandler\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Historienmodul\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Detektiv\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Quickfinder\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Webserver\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - ICONAG BACnet2B-CON\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hersteller: ICONAG\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 100\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0020\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 250 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 250\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0030\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 500 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 500\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0040\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 1.500 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 1.500\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0050\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 3.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 3.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0060\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 5.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 5.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0070\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 10.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 10.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0080\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 12.500 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 12.500\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0090\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 15.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 15.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0100\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 17.500 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 17.500\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0110\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 20.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 20.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0120\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 25.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 25.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0130\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 30.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 30.000\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0140\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 35.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 35.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0150\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 40.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 40.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0160\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 45.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 45.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.03.0170\tab\f0\b B-CON Runtime-Projektlizenz f\'FCr bis zu 50.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zur Kommunikation mit den Systemen der Geb\'E4udeautomation ist jede\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Runtime-Projektlizenz im Standard mit einem leistungsf\'E4higen OPC-DA-Client\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Version 3.0) ausgestattet. Dieser erm\'F6glicht die Kommunikation mit \'FCber 1.000\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 herstellerspezifischen Systemen \'FCber OPC-Server wie beispielsweise mit Honeywell,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Johnson Controls, Kieback & Peter, SAIA, Sauter und Siemens, sowie mit den OPCServern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 offener Standard-Systeme wie BACnet, KNX, LON, Modbus, M-Bus oder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profibus. Dar\'FCber hinaus bietet B-CON komfortable native Schnittstellen zu den\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wichtigsten offenen Standard-Systemen, die f\'FCr jedes Projekt einzeln zu lizenzieren\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 sind. Die Lizenzierung erfolgt gemeinsam mit der B-CON Runtime-Projektlizenz. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der vom Softwaresystem eingesetzte Softwareschutzstecker (Dongle) muss \'FCber einen Speicherbereich \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (mind. 4 GB) um eine zyklische Projektsicherung auf den Dongle zu \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 gew\'E4hrleisten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Jeweils inkl. einer B-CON Bedien-Client-Lizenz sowie einer B-CON Web-Client-Lizenz.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Objekteditor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Zeitschaltuhr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Berechtigungsvergabe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Alarmhandler\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Messagehandler (E-Mail-Versand)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Historienmodul\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Detektiv\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Quickfinder\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - Webserver\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - ICONAG BACnet2B-CON\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Bedien-Client-Lizenz\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - 1x B-CON Web-Client-Lizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Runtime-Projektlizenz BACnet 50.000\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.03\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projekt-Runtimelizenzen f\'FCr BACnet\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.04\tab\f0\b B-CON Redundanz-Lizenzen f\'FCr OPC-DA, Modbus und KNX\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.04.0010\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 250 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hinweis:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hersteller: ICONAG\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 250 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0020\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 500 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 500 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0030\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 1.500 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 1.500 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0040\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 5.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 5.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0050\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 10.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 10.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0060\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 12.500 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 12.500 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0070\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 15.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 15.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0080\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 17.500 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 17.500 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0090\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 20.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 20.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0100\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 25.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 25.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0110\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 30.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 30.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0120\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 35.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 35.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0130\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 40.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 40.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0140\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 45.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 45.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.04.0150\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 50.000 Datenpunkte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 50.000 Datenpunkte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.04\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Redundanz-Lizenzen f\'FCr OPC-DA, Modbus und KNX\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.05\tab\f0\b B-CON Redundanz-Lizenzen f\'FCr BACnet\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.05.0010\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 100 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hinweis:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hersteller: ICONAG\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 100 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0020\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 250 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 250 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0030\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 500 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 500 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0040\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 1.500 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 1.500 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0050\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 5.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 5.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0060\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 10.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 10.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0070\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 12.500 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 12.500 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0080\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 15.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 15.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0090\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 17.500 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 17.500 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0100\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 20.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 20.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0110\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 25.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 25.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0120\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 30.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 30.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0130\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 35.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 35.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0140\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 40.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 40.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0150\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 45.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 45.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.05.0160\tab\f0\b B-CON Hot-Standby-Redundanz f\'FCr bis zu 50.000 BACnet-Objekte\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON Hot-Standby-Redundanz basiert auf einer zweiten vollst\'E4ndigen B-CON Runtime-Installation. Hierzu ist eine zus\'E4tzliche Windows-Maschine (im weiteren Standby-Server genannt), mit identischer Hardware-, Betriebssystem- sowie Softwareausstattung wie auf dem Main-Server, zur Verf\'FCgung zu stellen. Mittels eines auf dem Standby-Server ausgef\'FChrten B-CON-Plugins wird permanent die Kommunikation zum Main-Server \'FCberwacht. Die Kommunikationspr\'FCfung wird im Standard zyklisch alle 10 Sekunden ausgef\'FChrt. Kann bei drei aufeinanderfolgenden Kommunikationspr\'FCfungen keine erfolgreiche Verbindung zum Main-Server hergestellt werden, wird der Failover-Fall ausgel\'F6st. In diesem Fall \'FCbernimmt automatisch der Standby-Server die B-CON Systemfunktionen. Alle Admin-Clients werden anschlie\'DFend automatisch an den Standby-Server verbunden. Eine automatische Anbindung der Web-Clients an den Standby-Server erfolgt in der aktuellen Version nicht. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ein sp\'E4teres R\'FCckschalten vom Standby-Server auf den Main-Server muss manuell ausgef\'FChrt werden. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Um eine einwandfreie Funktion der B-CON Hot-Standby-Redundanz gew\'E4hrleisten zu k\'F6nnen, m\'FCssen die B-CON-Systeme auf Main- und Standby-Server hinsichtlich B-CON Release- und Projekt-Stand zu jederzeit identisch gehalten werden. Die Installation eines B-CON Updates (neuer Release-Stand) auf dem Main-Server erfordert die Installation des identischen B-CON Updates auf dem Standby-Server. \'C4nderungen am B-CON Projekt auf dem Main-Server m\'FCssen anschlie\'DFend manuell auf dem Standby-Server eingespielt werden. Eine automatische Anpassung des B-CON Release-Standes bzw. Aktualisierung des B-CON Projektes auf dem Standby-Server erfolgt nicht.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Redundanz-Funktion muss durch einen ICONAG-Systemtechniker im betreffenden B-CON-Projekt eingerichtet werden. Diese Leistung ist in dieser Position nicht enthalten und muss gesondert beauftragt werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Inkl. B-CON Redundanzlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Hot-Standby-Redundanz f\'FCr bis zu 50.000 BACnet-Objekte\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.05\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Redundanz-Lizenzen f\'FCr BACnet\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.06\tab\f0\b B-CON Projektlizenzen zum Benutzerzugriff\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.06.0010\tab\f0\b B-CON Bedien-Client-Lizenz\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 B-CON Bedien-Client-Lizenz zur Installation einer kompletten Client-Anwendung auf\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 einem Windows-System je Bedien-Client-Lizenz ab dem 2. Client\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hersteller: ICONAG\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Typ: B-CON Bedien-Client-Lizenz\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.06.0020\tab\f0\b B-CON Web-Client-Lizenz\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 B-CON Web-Client-Lizenz zum Anzeigen und Bedienen von \'DCbersichts-, Anlagen und\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Detailbildern, zum St\'F6rungsmanagement sowie der optional lizenzierten EnMSFunktionen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'FCber HTML5, je Web-Client-Lizenz ab dem 2. Client\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Web-Client-Lizenz\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.06\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektlizenzen zum Benutzerzugriff\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.07\tab\f0\b B-CON Projektlizenzen f\'FCr erweiterte Funktionsmodule zum technischen Geb\'E4udemanagement\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.07.0010\tab\f0\b B-CON Funktionserweiterung "Simple SMS"\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Fu\u776 ?r die einfache Weiterleitung per SMS-Versand. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Bitte beachten Sie, dass es bei dieser Funktionserweiterung keine Upgrade-Option auf unser Funktionsmodul Multimessage (z.B. Fern-Quittierung, Fax-Versand, Meldeketten etc.) gibt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.07.0020\tab\f0\b B-CON Funktionsmodul Multimessage\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 zur automatisierten Verteilung von Meldungen an bis zu 100 Empf\'E4nger.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Funktionsumfang:\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Meldungsversand per E-Mail, Fax und SMS\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Fern-Quittierungsfunktion\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bildung von Empf\'E4ngergruppen\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Schichtbetrieb und Weiterleitung\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 bei Nichterreichen (Eskalation)\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Sprachausgabe \'FCber Telefon\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Netzwerkschnittstelle \'FCber TCP/IP Sockets\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 und Named Pipe\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Text-to-Speech Standard (dynamische\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wandlung von Texten in deutsche Sprache)\par
\pard\ls1\ilvl0{\listtext\f6\fs20 \u61623 ?\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 DDE- und COM-Schnittstelle\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr den vollen Funktionsumfang ist ein Mobilfunk-Gateway erforderlich.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.07.0030\tab\f0\b B-CON Multimessage Funktionserweiterung SIP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anbindung an Telefonanlagen (SIP). Es ist damit m\'F6glich, Nachrichten auf das Display eines an der Telefonanlage angeschlossenen Ger\'E4tes, auszugeben. Inkl. ESPA-Schnittstelle und Saphir VoIP-Treiber (1 Kanal).\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bitte beachten Sie, dass das Feature \u8222 ?Secure-Boot\u8220 ? im UEFI-BIOS unter Windows Server 2019 deaktiviert werden muss.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.07.0040\tab\f0\b Mobilfunk-Gateway 4G 1 Kanal\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 VoIP Gateway, inkl. Magnethaftantenne mit 2 m Kabel, f\'FCr SMS Versand und Sprachausgabe (F\'FCr eigenst\'E4ndige ausgew\'E4hlte Alternativprodukte kann keine Funktionsgew\'E4hrleistung \'FCbernommen werden).\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Beistellung einer Mobilfunkkarte erfolgt bauseits! Die ICONAG-Leittechnik empfiehlt den Einsatz einer Mobilfunkkarte mit SMS-Flatrate ohne Datenoption.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.07.0050\tab\f0\b B-CON Funktionsmodul \u8222 ?Handlungsanweisung\u8220 ?\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Das Funktionsmodul \u8222 ?Handlungsanweisung\u8220 ? muss die dynamische\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zuordnung von Handlungsanweisungen sowie Verfahrenstexten\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 erm\'F6glichen. Die Verwaltung der Handlungsanweisungen und\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Verfahrenstexte muss durch den Nutzer m\'F6glich sein. Eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Mehrfachverkn\'FCpfung von Handlungsanweisungen und\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Verfahrenstexten an einen Alarmdatenpunkt muss dabei ebenso\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 m\'F6glich sein, wie der direkte Aufruf der Handlungsanweisungen aus\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 dem Alarmhandler heraus. Zur Erleichterung der Textpflege muss der\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Import von Textdateien m\'F6glich sein. Die Integration in die bestehende\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 GLT muss als PlugIn erfolgen und darf keine externe\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Softwareapplikation darstellen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON FM-HA\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.07.0060\tab\f0\b B-CON Funktionsmodul \u8222 ?Kostenstellenverteilung\u8220 ?\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Das Funktionsmodul \u8222 ?Kostenstellenverteilung\u8220 ? muss eine flexible\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Zuordnung von Z\'E4hlerdatenpunkten der %-ualen Zugeh\'F6rigkeit zu\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Kostenstellen erm\'F6glichen. Dabei m\'FCssen die Kostenstellen frei\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 definierbar sein. Die Pflege der entsprechenden Einheiten erfolgt\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 unmittelbar am Datenpunkt so, dass das Kostenstellenmodul direkt die\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 richtigen Einheiten darstellen kann. Der Nutzer muss die M\'F6glichkeit\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 haben, sich verschiedene Ansichten auf Kostenstellen zu speichern und\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 jederzeit wieder aufzurufen. Der Zeitraum zur Auswertung muss vom\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Kunden frei einstellbar sein, soll zudem aber \'FCber\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Schnellauswahlfunktionen wie Wochen- bzw. Monatsauswertungen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 verf\'FCgen. Die Integration muss in die bestehende GLT erfolgen und darf\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 keine externe Softwareapplikation darstellen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON FM-KSV\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.07.0070\tab\f0\b B-CON FIAS-Schnittstelle\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f3\fs20 B-CON FIAS-Schnittstelle\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f3\fs20 Softwareschnittstelle f\'FCr die Anbindung einer\line Hotelbuchungssoftware mittels FIAS-Protokoll an die\line B-CON.\line\'DCber das FIAS-Protokoll werden\line Zimmer-Beleginformationen (CheckIn/CheckOut) an das\line B-CON-System \'FCbergeben.\line\line Komplett wie vor beschrieben liefern, installieren und\line in Betrieb nehmen.\line\line Hersteller: ICONAG\line Typ: B-CON FIAS\line\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.07.0080\tab\f0\b B-CON Active Directory Anbindung\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Benutzerpr\'FCfung gegen lokales Active Direktory (Azure Active Directory wird nicht unterst\'FCtzt).\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Manuelle Benutzersynchronisierung mit Active Directory Gruppe.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Passwortpr\'FCfung gegen Active Directory.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die B-CON-spezifischen Benutzereinstellungen m\'FCssen in der B-CON Berechtigungsvergabe vorgenommen werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Einrichtung erfolgt im Rahmen der Inbetriebnahmeleistungen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON Active Directory Anbindung\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.07.0090\tab\f0\b B-CON Technisches Monitoring\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1. Leistungsgegenstand\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ziel des technischen Monitorings ist die kontinuierliche \'DCberwachung, Bewertung und Visualisierung der Funktionsf\'E4higkeit technischer Anlagen und Gewerke.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das Monitoring soll Betriebsparameter in Echtzeit erfassen, analysieren und Abweichungen vom Soll-Zustand automatisiert erkennen. Die Ergebnisse sind in geeigneter Form aufzubereiten und f\'FCr weiterf\'FChrende Analysen bereitzustellen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 2. Funktionale Anforderungen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das anzubietende System muss mindestens folgende Funktionen erf\'FCllen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 KPI-basierte \'DCberwachung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Definition, Konfiguration und Verwaltung von Key Performance Indicators (KPIs)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Regelbasierte Bewertung von Anlagenzust\'E4nden durch Vergleich von Ist- und Sollwerten\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bildung eines st\'FCndlichen Erf\'FCllungsgrades (in %) zur Bewertung der Anlagenperformance\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Flexible KPI-Typen\line  Unterst\'FCtzung typischer Anwendungsf\'E4lle, u. a.:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Sollwert-Abweichungen (inkl. Toleranz und Totzeit)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Betriebslogiken (z. B. Umw\'E4lzpumpen in Abh\'E4ngigkeit von Au\'DFentemperaturen)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Speicherzust\'E4nde (z. B. Pufferspeicher inkl. Ladezustandsbewertung)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Parametrierbarkeit\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Individuelle Definition von Grenzwerten (optimal / auff\'E4llig / kritisch)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einstellbarer Auswertungszyklus (z. B. 10\u8211 ?60 Sekunden)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Verwendung beliebiger Datenpunkte als Ein- und Ausgangswerte\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Historisierung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Automatische Speicherung der KPI-Ergebnisse in einem Zeitraster (mind. st\'FCndlich)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bereitstellung der Daten f\'FCr Trendanalysen und Auswertungen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 3. Visualisierung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das System muss eine anschauliche Visualisierung der Monitoring-Ergebnisse erm\'F6glichen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Darstellung als Heatmap zur schnellen Identifikation kritischer Zust\'E4nde \'FCber Zeitr\'E4ume\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Farblich codierte Zust\'E4nde (z. B. gr\'FCn / gelb / rot) entsprechend definierter Grenzwerte\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Darstellung historischer Verl\'E4ufe (z. B. Liniendiagramme)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Integration in eine webbasierte Benutzeroberfl\'E4che (Dashboard-Funktionalit\'E4t)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 4. Systemintegration und Betrieb\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Integration in bestehende B-CON-Projekte (mindestens Release G oder h\'F6her)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bereitstellung als eigenst\'E4ndiges, optionales Softwaremodul (Plugin-Architektur)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Unterst\'FCtzung des Live-Betriebs inkl. dynamischer Anpassung von KPIs\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 5. Bedienbarkeit und Konfiguration\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bereitstellung einer intuitiven Benutzeroberfl\'E4che zur KPI-Konfiguration\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 M\'F6glichkeit zum Anlegen, Bearbeiten und L\'F6schen von KPIs im laufenden Betrieb\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Klare Strukturierung der Parameter (Grundeinstellungen und typspezifische Parameter)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Unterst\'FCtzung bei der Fehlersuche (z. B. Statusanzeige aktiver KPIs, Logbuchintegration)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 6. Qualit\'E4t und Zuverl\'E4ssigkeit\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Sicherstellung vollst\'E4ndiger Datenerfassung f\'FCr valide Auswertungen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Robuste Fehlererkennung (z. B. fehlende Datenpunkte, unvollst\'E4ndige Daten)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Nachvollziehbare Protokollierung von Fehlerzust\'E4nden\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Vermeidung von Fehlalarmen durch konfigurierbare Totzeiten und Pr\'FCfzyklen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 7. Zielsetzung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ziel des Systems ist die transparente Darstellung von Effizienz, Verf\'FCgbarkeit und Betriebsqualit\'E4t technischer Anlagen sowie die fr\'FChzeitige Erkennung von Abweichungen und Optimierungspotenzialen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Anzahl der anzulegenden KPIs ist nicht beschr\'E4nkt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: B-CON TMon\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.07\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektlizenzen f\'FCr erweiterte Funktionsmodule zum technischen Geb\'E4udemanagement\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.08\tab\f0\b B-CON Projektlizenzen zum Energie-Management\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.08.0010\tab\f0\b B-CON Energie-Management Grundmodul\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Das ENMS Grundmodul erm\'F6glicht die Auswertung und den Vergleich mehrerer Messstellen. Die daraus resultierenden Energieberichte k\'F6nnen als PDF ausgegeben und lokal auf dem Bedienplatzrechner gespeichert werden. Die Bedienung des Grundmoduls muss auf Basis von HTML5 Technologie und somit unabh\'E4ngig von bestimmten Webbrowsern und Betriebssystemen erfolgen k\'F6nnen. Das Grundmodul verf\'FCgt \'FCber eine Berechtigungsvergabe mit deren Hilfe, dem jeweiligen Anwender explizit nur seine eigenen Messstellen zur Auswertung zur Verf\'FCgung gestellt werden.  \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Folgende Funktionen und Prorgammmodule sind standardm\'E4\'DFig enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - EnMS - Auswertung\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - EnMS - Manuelle Messdatenerfassung\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - EnMS - Datenimport (CSV bzw. MSCONS)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - EnMS - Messstellenverwaltung\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Das B-CON Energie-Management Grundmodul kann nur in Verbindung mit einer B-CON Runtime-Projektlizenz (BACnet oder Modbus/KNX/OPC) lizenziert werden. \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Im B-CON Energie-Management Grundmodul k\'F6nnen Messwertdatenpunkte im Umfang der B-CON Runtime-Projektlizenz angelegt und verwendet werden. Die Treiberschnittstellen zur Anbindung von Z\'E4hlersystemen und Messeinrichtungen beschr\'E4nken sich auf den Umfang der Treiberschnittstellen der Runtime-Projektlizenz, zuz\'FCglich lizenzierten B-CON Treiberschnittstellen oder beigestellten OPC-Treibern von Drittanbietern. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Hersteller: ICONAG\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Typ: ENMS Grundmodul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.08.0020\tab\f0\b B-CON Energie-Management Erweiterungsmodul Wetterdatenservice\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Das ENMS Erweiterungsmodul Wetterdatenservice zur Einbettung von Wetter-Prognosedaten. Aktualisierung der Prognosedaten wahlweise 2x t\'E4glich oder \u189 ?-st\'FCndlich.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Typ: ENMS Zusatzmodul Wetterdatenservice\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.08.0030\tab\f0\b B-CON Energie-Management Erweiterungsmodul Witterungsbereinigung\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Beinhaltet die Witterungsbereinigung von j\'E4hrlichen Gesamtverbr\'E4uchen. Grundlage bildet das "Klimafaktoren-Verzeichniss" des Deutschen Wetterdienstes im XML-Format. Es erfolgt ein automatisierter Import der XML-Datei aus einem lokalen festgelegten Speicherpfad.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Typ: ENMS Erweiterungsmodul Witterungsbereinigung\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.08\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektlizenzen zum Energie-Management\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 01.09\tab\f0\b OPC-Server\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 01.09.0010\tab\f0\b M-Bus OPC-Server 3\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 M-Bus OPC-Server zur Anbindung von max. 3 Standard M-BUS Zahlern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Voraussetzungen:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Das M-Bus-Netzwerk muss bereits mittels Pegelwandler und COM-Server im Ethernet-Netzwerk vom B-CON Server aus erreichbar sein. Die Lieferung und Installation der ben\'F6tigten Hardware ist kein Bestandteil dieser Position.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Liefern.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0020\tab\f0\b M-Bus OPC-Server 20\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 M-Bus OPC-Server zur Anbindung von max. 20 Standard M-BUS Zahlern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Voraussetzungen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das M-Bus-Netzwerk muss bereits mittels Pegelwandler und COM-Server im Ethernet-Netzwerk vom B-CON Server aus erreichbar sein. Die Lieferung und Installation der ben\'F6tigten Hardware ist kein Bestandteil dieser Position.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0030\tab\f0\b M-Bus OPC-Server 60\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 M-Bus OPC-Server zur Anbindung von max. 60 Standard M-BUS Zahlern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Voraussetzungen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das M-Bus-Netzwerk muss bereits mittels Pegelwandler und COM-Server im Ethernet-Netzwerk vom B-CON Server aus erreichbar sein. Die Lieferung und Installation der ben\'F6tigten Hardware ist kein Bestandteil dieser Position.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0040\tab\f0\b M-Bus OPC-Server 250\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 M-Bus OPC-Server zur Anbindung von max. 250 Standard M-BUS Zahlern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Voraussetzungen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das M-Bus-Netzwerk muss bereits mittels Pegelwandler und COM-Server im Ethernet-Netzwerk vom B-CON Server aus erreichbar sein. Die Lieferung und Installation der ben\'F6tigten Hardware ist kein Bestandteil dieser Position.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0050\tab\f0\b M-Bus OPC-Server 500\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 M-Bus OPC-Server zur Anbindung von max. 500 Standard M-BUS Zahlern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Voraussetzungen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das M-Bus-Netzwerk muss bereits mittels Pegelwandler und COM-Server im Ethernet-Netzwerk vom B-CON Server aus erreichbar sein. Die Lieferung und Installation der ben\'F6tigten Hardware ist kein Bestandteil dieser Position.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0060\tab\f0\b M-Bus OPC-Server 1.000\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 M-Bus OPC-Server zur Anbindung von max. 1.000 Standard M-BUS Zahlern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Voraussetzungen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das M-Bus-Netzwerk muss bereits mittels Pegelwandler und COM-Server im Ethernet-Netzwerk vom B-CON Server aus erreichbar sein. Die Lieferung und Installation der ben\'F6tigten Hardware ist kein Bestandteil dieser Position.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0070\tab\f0\b M-Bus OPC-Server >1.000\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 M-Bus OPC-Server zur Anbindung von mehr als 1.000 Standard M-BUS Zahlern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Voraussetzungen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das M-Bus-Netzwerk muss bereits mittels Pegelwandler und COM-Server im Ethernet-Netzwerk vom B-CON Server aus erreichbar sein. Die Lieferung und Installation der ben\'F6tigten Hardware ist kein Bestandteil dieser Position.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0080\tab\f0\b Siemens Kommunikationstreiber\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Kommunikationstreiber (OPC Server) zur Anbindung von Siemens Steuerungen und\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Siemens-kompatiblen Steuerungen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eigenschaften:\par
\pard\ls27\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Lese- und Schreibzugriff auf Prozess- und Diagnosedaten in Siemens- und Siemenskompatiblen Steuerungen\par
\pard\ls27\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Unterst\'FCtzung optimierter Datenbl\'F6cke in Siemens S7-1200- and S7-1500-Steuerungen\par
\pard\ls27\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Keine Anpassungen des Steuerungsprogramms notwendig\par
\pard\ls27\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Namespace-Konfiguration \'FCber Durchsuchen des Siemens S7-1200- und S7-1500-Namespace\par
\pard\ls27\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Benutzerfreundliche grafische Konfigurationsschnittstelle\par
\pard\ls27\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Intelligenter Assistent f\'FCr Konfiguration in 3 Schritten\par
\pard\ls27\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Import symbolischer Namen aus Siemens TIA Portal- und STEP 7-Projekten\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: Softing\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: Siemens Kommunikationstreiber\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0090\tab\f0\b SNMP Kommunikationstreiber\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Kommunikationstreiber (OPC Server) zur Anbindung von Ger\'E4ten mit SNMP-Schnittstelle.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eigenschaften:\par
\pard\ls28\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 SNMP-Zugriff auf Ger\'E4te verschiedener Hersteller \'FCber MIB Import und SNMP Browse\par
\pard\ls28\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 High Performance-Protokoll f\'FCr Kommunikation mit gro\'DFen Datenmengen \'FCber OPC\par
\pard\ls28\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Keine Begrenzung bei Anzahl der angeschlossenen Steuerungen bzw. Netzger\'E4te und Variablen\par
\pard\ls28\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bequeme Inbetriebnahme durch symbolische Adressierung (Alias Browsing)\par
\pard\ls28\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erh\'F6hte Verf\'FCgbarkeit durch kontinuierliche Leitungs\'FCberwachung und umfangreiche Kommunikationsdiagnose\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Unterst\'FCtzte Steuerungen:\par
\pard\ls29\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Steuerungen und Netzger\'E4te mit SNMP-Unterst\'FCtzung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Unterst\'FCtzte Protokolle:\tab\par
\pard\ls29\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 unterst\'FCtzt SNMP V1 (vollst\'E4ndig), V2 (ohne Datensicherheit)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Liefern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hersteller: Softing\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: SNMP Kommunikationstreiber\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0100\tab\f0\b OPC UA Kommunikationsteiber 1 Connection\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Unterst\'FCtzung von OPC UA, \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zugriff von 100 OPC UA-Clients und f\'FCr Zugriff auf 1 OPC UA -Server\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: ICONAG - OPC UA 1\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0110\tab\f0\b OPC UA Erweiterungslizenz 50 Connections\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 OPC UA Server-Erweiterungslizenz 50 f\'FCr\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 gleichzeitigen Zugriff auf insgesamt bis zu 50 OPC UA-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ben\'F6tigt den OPC UA Kommunikationstreiber.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: ICONAG - OPC UA EW 50\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 01.09.0120\tab\f0\b OPC UA Erweiterungslizenz 100 Connections\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 OPC UA Server-Erweiterungslizenz 100,\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 erh\'F6ht die Anzahl der gleichzeitigen Zugriffe auf OPC UA-Server von 50 auf 100.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ben\'F6tigt die Erweiterungslizenz 50.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ: ICONAG - OPC UA EW 100\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01.09\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b OPC-Server\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 01\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Software\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02\tab\f0\b Dienstleistung\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.01\tab\f0\b Pflichtenheft\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hinweis:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Der Workshop und die Erstellung des gemeinsamen Pflichtenhefts ist vor dem ersten Projekt einmalig durchzuf\'FChren. F\'FCr alle Folgeauftr\'E4ge wird dieses f\'FCr Dienstleitungen herangezogen, so lange seitens des Bauherrn keine ma\'DFgeblichen \'C4nderungen an der Errichtung von Management- und Bedienfunktionen gew\'FCnscht sind.\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.01.0010\tab\f0\b Erstellung Pflichtenheft gem\'E4\'DF B-CON Standard\par
\pard\plain\s0\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Erstellung eines Pflichtenheftes auf Basis des B-CON Standards. \par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Gemeinsam dem Bauherrn und dem Fachplaner werden die einzelnen Punkte hinsichtlich Hardware, Software und Dienstleistungen im B-CON Standard erl\'E4utert und die zutreffenden Kriterien im Dokument festgehalten.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Das fertige Dokument wird allen Projektbeteiligten im Anschluss in digitaler Form (PDF-Format) zur Verf\'FCgung gestellt und dient als Projektpflichtenheft.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Die Besprechung findet via Online-Meeting statt.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Pauschal.\par
\pard\plain\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.01.0020\tab\f0\b Erstellung Pflichtenheft gem\'E4\'DF Vorgabe\line\par
\pard\plain\s0\li1701\ri1701\tx8789\wpparflg64\keepn\keep\plain\fs20 Vor der Realisierung des Systems ist gemeinsam mit dem Bauherrn und dem Fachplaner ein\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Pflichtenheft zu erstellen, welches die Einzelheiten der Funktionalit\'E4t der Management- und Bedieneinrichtung festlegt und Grundlage f\'FCr die Leistungserbringung wird.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Pauschal.\par
\pard\plain\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.01\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Pflichtenheft\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.02\tab\f0\b Projektmanagement\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.02.0010\tab\f0\b Teilnahme an Projektbesprechungen vor Ort\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Tagessatz f\'FCr die Teilnahme an Projektbesprechungen zur Abstimung des grundlegenden Aufbaus des MBE-Systems und der Projektumsetzung.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Inkl. Reisekosten und \'DCbernachtung.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.02.0020\tab\f0\b Teilnahme an Projektbesprechungen via Online-Meeting\par
\pard\plain\s0\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Stundensatz f\'FCr die Teilnahme an Projektbesprechungen zur Abstimmung des grundlegenden Aufbaus des MBE-Systems und der Projektumsetzung via Online-Meeting.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.02.0030\tab\f0\b Dokumentation (digital)\par
\pard\plain\s0\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Zusammenstellung aller von B-CON angebotenen\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Dokumentationsm\'F6glichkeiten.\par
\pard\plain\li1701\ri1701\tx1701\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Alle Bildschirmseiten\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Alle Diagrammseiten\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Objektliste\par
\pard\plain\li1701\ri1701\tx1701\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Archivieren des gesamten Projektes in einem ZIP-Archiv. \par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Diese Dokumentation wird dem Auftraggeber per E-Mail oder als Downloadlink zur Verf\'FCgung gestellt.\par
\pard\plain\li1701\ri1701\tx1701\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\sa113\tx1701\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.02.0040\tab\f0\b Dokumentation\line  (gedruckt)\par
\pard\plain\s0\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Dokumentation und Ausdruck aller von B-CON angebotenen\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Dokumentationsm\'F6glichkeiten.\par
\pard\plain\li1701\ri1701\tx1701\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Alle Bildschirmseiten\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Alle Diagrammseiten\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Objektliste\par
\pard\plain\li1701\ri1701\tx1701\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Archivieren des gesamten Projektes auf einem Datentr\'E4ger (USB-Stick/SD-Karte). \par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Dokumentation und Datentr\'E4ger m\'FCssen dem Betreiber der\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Anlage in einfacher Ausf\'FChrung \'FCbergeben werden. \par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Hierzu ist ein A4-Ordner zu erstellen, der alle aktivierten Module sowie die Kopien aller\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Bildschirmseiten sowie die aktuell zum Zeitpunkt der \'DCbergabe\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 vorliegende Objektliste beinhaltet.\par
\pard\plain\li1701\ri1701\sa113\tx1701\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.02\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Projektmanagement\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.03\tab\f0\b Grundkonfiguration Management- und  Bedieneinrichtung\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.03.0010\tab\f0\b Grundkonfiguration B-CON Server (Hardware)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Grundkonfiguration der Betriebssysteme vornehmen und alle ben\'F6tigten Softwarekomponenten installieren und betriebsfertig einrichten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Installation und Einrichtung der B-CON Runtime-Umgebung vornehmen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Einrichten und pr\'FCfen der Netzwerkverbindung.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Pauschal je Server-System.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hinweis: \par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Diese Position findet nur Anwendung bei physikalischen Server-Systemen, die von ICONAG geliefert oder ICONAG vor der Inbetriebnahme vom Auftraggeber zur Verf\'FCgung gestellt werden. Die Leistungserbringung erfolgt im ICONAG B\'FCro. F\'FCr alle weiteren Systeme (physikalische Systeme vor Ort oder virtualisierte Systeme) erfolgt die Grundkonfiguration im Rahmen der Inbetriebnahme. \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.03.0020\tab\f0\b Grundkonfiguration B-CON Browser-Client (Hardware)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Grundkonfiguration der Betriebssysteme vornehmen und alle ben\'F6tigten Softwarekomponenten installieren und betriebsfertig einrichten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Einrichten und pr\'FCfen der Netzwerkverbindung.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je B-CON Browser-Client.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis: \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Diese Position findet nur Anwendung bei physikalischen Client-Systemen, die von ICONAG geliefert oder ICONAG vor der Inbetriebnahme vom Auftraggeber zur Verf\'FCgung gestellt werden. Die Leistungserbringung erfolgt im ICONAG B\'FCro. F\'FCr alle weiteren Systeme (physikalische Systeme vor Ort oder virtualisierte Systeme) erfolgt die Grundkonfiguration im Rahmen der Inbetriebnahme. \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.03.0030\tab\f0\b B-CON Hot-Standby-Redundanz einrichten\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Herstellen und pr\'FCfen der Redundanz-Funktionen zwischen den MBE-, Datenbank- und Schnittstellen-Servern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis: \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Diese Position findet nur Anwendung bei physikalischenn Serversystemen, die von ICONAG geliefert oder ICONAG vor der Inbetriebnahme vom Auftraggeber zur Verf\'FCgung gestellt werden. Die Leistungserbringung erfolgt im ICONAG B\'FCro. F\'FCr alle weiteren Systeme (physikalische Systeme vor Ort oder virtualisierte Systeme) erfolgt die Einrichtung im Rahmen der Inbetriebnahme. \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.03.0040\tab\f0\b B-CON Benutzer anlegen \par
\pard\plain\s0\li1701\ri1701\tx8789\wpparflg64\keepn\keep\plain\fs20 Erstmaliges Anlegen von Benutzern samt Berechtigungsdetails:\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 - Benutzername anlegen\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 - Berechtigungsprofil anlegen\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 - Kennwort festlegen\par
\pard\li1701\ri1701\tx8789\wpparflg64\keepn\keep\plain\fs20 - G\'FCltigkeitszeitraum\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 - G\'FCltigkeitsdauer\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 - Alarmfilterung einrichten\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx8789\wpparflg64\keepn\keep\plain\fs20 Die Festlegung der Benutzerhierarchie erfolgt nach den Vorgaben des Auftraggebers.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.03\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Grundkonfiguration Management- und  Bedieneinrichtung\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.04\tab\f0\b B-CON Projektierung X2B-CON-Treiber\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.04.0010\tab\f0\b BACnet2B-CON: Grundkonfiguration\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Grundkonfiguration der BACnet2B-CON Treiberschnittstelle vornehmen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\ls30\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 BACnet-Kommunikationsparameter gem\'E4\'DF Kundenvorgabe einrichten:\par
\pard\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Device-ID\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Device-Name\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Adapter-IP\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - UDP-Port\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Device-ID Scanbereich\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Adressierungsschema\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - BBMDs anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - BACnet Schreibpriorit\'E4t\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - B-CON Kommunikation\par
\pard\plain\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\ls30\ilvl0{\listtext\f6\fs20 \'B7\tab}\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Netzwerk-Scan zur stichprobenartigen Pr\'FCfung der BACnet-Kommunikation \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Pauschal.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.04.0020\tab\f0\b KNX2B-CON: KNX-Schnittstelle anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 KNX-Schnittstelle (IP oder USB) im KNX2B-CON Treiber anlegen und konfigurieren mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls31\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1x KNX-Schnittstelle anlegen und konfigurieren \par
\pard\ls31\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Falls vorhanden) Import einer, gem\'E4\'DF ICONAG KNX-Schnittstellenvorgaben, projektfertig \'FCbergebenen ETS-Exportdatei im .ESF- oder .CSV-Format.\par
\pard\ls31\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Sobald eine physikalische Verbindung zur KNX-Schnittstelle besteht, wird ein lesender, stichprobenartiger Datenpunkttest \'FCber den Kommunikationsmodus des KNX2B-CON-Konfigurators durchgef\'FChrt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Folgende Informationen sind je KNX-Schnittstelle vom Auftraggeber zur Verf\'FCgung zu stellen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls32\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Typ (USB, IP-Routing, IP-Tunneling)\par
\pard\ls32\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Name\par
\pard\ls32\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 IP-Adresse (nur IP)\par
\pard\ls32\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Port (nur IP)\par
\pard\ls32\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Protokoll (nur IP: Auto, UDP, TCP)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je anzulegender KNX-Schnittstelle.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.04.0030\tab\f0\b KNX2B-CON: Datenpunkt anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Beinhaltet das Anlegen eines KNX-Datenpunktes (KNX-Gruppenadresse) zu einer bereits im KNX2B-CON Treiber angelegten KNX-Schnittstelle oder in einer bestehenden KNX2B-CON-Konfigurationsdatei gem\'E4\'DF einer vom Kunden beigestellten Datenpunktliste, die alle ben\'F6tigten Parameter gem\'E4\'DF ICONAG KNX-Schnittstellenvorgaben beinhaltet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Aus der neuen Konfiguration wird im Anschluss eine Konfiguartionsdatei erzeugt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Konfigurationsdatei kann nach einmaliger Erstellung f\'FCr den Datenpunkt-Import einer beiliebigen Anzahl von baugleichen KNX-Systemen verwendet werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 F\'FCr die Erstellung ist ICONAG eine entsprechende Zuordnungsliste im XLSX- oder CSV-Format mit den anzulegenden KNX-Gruppenadressen, Klartextbezeichnungen, Einheiten, Datenpunkttyp (DPT), Verwendung, Adressname und Zust\'E4nden je Datenpukt zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Je anzulegendem Datenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.04.0040\tab\f0\b Modbus2B-CON: Modbus-Ger\'E4t anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Modbus-Ger\'E4t (IP) im Modbus2B-CON Treiber anlegen und konfigurieren mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls33\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1x Modbus-Ger\'E4t anlegen und konfigurieren \par
\pard\ls33\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Falls vorhanden) Import einer, gem\'E4\'DF ICONAG Modbus-Schnittstellenvorgaben, projektfertig \'FCbergebenen Modbus2B-CON-Konfig, Codesys-SYM- oder e!Cockpit-CSV-Datei.\par
\pard\ls33\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Sobald eine physikalische Verbindung zum Modbus-Ger\'E4t besteht, wird ein lesender, stichprobenartiger Datenpunkttest \'FCber den Kommunikationsmodus des Modbus2B-CON-Konfigurators durchgef\'FChrt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Folgende Informationen sind je Modbus-Ger\'E4t vom Auftraggeber zur Verf\'FCgung zu stellen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls34\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Name\par
\pard\ls34\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Unit-ID\par
\pard\ls34\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 IP-Adresse\par
\pard\ls34\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Port\par
\pard\ls34\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pollrate\par
\pard\ls34\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Byte Order\par
\pard\ls34\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Word Order\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ist keine Konfigurationsdatei (Modbus2B-CON-Konfig, Codesys-SYM- oder e!Cockpit-CSV-Datei) vorahanden, ist zus\'E4tzlich die Erstellung einer Modbus-Konfiguration bei ICONAG zu beauftragen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je anzulegendem Modbus-Ger\'E4t.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.04.0050\tab\f0\b Modbus2B-CON: Datenpunkt anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Beinhaltet das Anlegen eines Modbus-Datenpunktes zu einem bereits im Modbus2B-CON Treiber angelegten Modbus-Ger\'E4tes oder in einer bestehenden Modbus2B-CON-Konfigurationsdatei gem\'E4\'DF einer vom Kunden beigestellten Datenpunktliste, die alle ben\'F6tigten Parameter gem\'E4\'DF ICONAG Modbus-Schnittstellenvorgaben beinhaltet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Aus der neuen Konfiguration wird im Anschluss eine Konfiguartionsdatei erzeugt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Konfigurationsdatei kann nach einmaliger Erstellung f\'FCr den Datenpunkt-Import einer beiliebigen Anzahl von baugleichen Modbus-Ger\'E4ten verwendet werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 F\'FCr die Erstellung ist ICONAG eine entsprechende Zuordnungsliste im XLSX- oder CSV-Format mit den anzulegenden Modbus-Registeradressen, Klartextbezeichnungen, Einheiten, Datenpunkttyp und Zust\'E4nden je Datenpukt zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Je anzulegendem Datenpunkt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.04\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektierung X2B-CON-Treiber\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.05\tab\f0\b B-CON Projektierung OPC-Server\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.05.0010\tab\f0\b OPC-Server: Installation und Grundkonfiguration \par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Von ICONAG gelieferten OPC-Server eines Fremdherstellers auf dem B-CON MBE-Server installieren und Grundkonfiguration vornehmen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Pauschal je OPC-Server.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.05.0020\tab\f0\b OPC-Server: Kommunikationsteilnehmer anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Kommunikationsteilnehmer im bereits funktionsbereit auf dem B-CON MBE-Server eingerichteten OPC-Server mit folgendem Leistungsumfang anlegen und konfigurieren:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls35\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1x Kommunikationsteilnehmer anlegen und konfigurieren \par
\pard\ls35\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (Falls vorhanden) Import einer projektfertig \'FCbergebenen Symbol-/Konfigurationsdatei oder "browsen" des Kommunikationsteilnehmers und \'DCbernhame der Datenpunkte.\par
\pard\ls35\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Sobald eine physikalische Verbindung zum Kommunikationsteilnehmer besteht, wird ein lesender, stichprobenartiger Datenpunkttest \'FCber den B-CON OPC-Client durchgef\'FChrt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Kommunikationsteilnehmer sind ICONAG vorab alle ben\'F6tigten Kommunikations- und Ger\'E4teinformationen (z.B. IP-Adresse, Ger\'E4tename, Pollrate, etc.) zu \'FCbergeben. Die ben\'F6tigten Parameter k\'F6nnen sich je Kommunikationsprotokoll unterscheiden und werden treiberspezifisch von ICONAG angegeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je anzulegendem Kommunikationsteilnehmer.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.05.0030\tab\f0\b OPC-Server: Datenpunkt anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Beinhaltet das Anlegen eines OPC-Datenpunktes zu einem bereits im OPC-Server angelegten Kommunikationsteilnehmers gem\'E4\'DF einer vom Kunden beigestellten Datenpunktliste, die alle ben\'F6tigten Parameter gem\'E4\'DF ICONAG OPC-Schnittstellenvorgaben beinhaltet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 F\'FCr die Erstellung ist ICONAG eine entsprechende Zuordnungsliste im XLSX- oder CSV-Format mit den anzulegenden OPC-Datenpunktnamen, Klartextbezeichnungen, Einheiten, Datenpunkttyp und Zust\'E4nden je Datenpukt zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Je anzulegendem Datenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.05\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektierung OPC-Server\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.06\tab\f0\b B-CON Projektierung Datenpunktkonfiguration\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.06.0010\tab\f0\b Datenpunkt\'FCbernahme von B-CON Kommunikationsserver\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Leistung beinhaltet, den Import von Datenpunkten in ein B-CON Server-Projekt die von \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 einem \b B-CON-Kommunikationsserver\b0  \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 zur Verf\'FCgung gestellt werden und unmittelbar in das Server-Projekt \'FCbernommen werden k\'F6nnen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Je Datenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.06.0020\tab\f0\b Datenpunkt\'FCbernahme von BACnet2B-CON durch "Online-Browsing"\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Leistung beinhaltet, den Import von Datenpunkten in ein B-CON Server- oder B-CON-Kommunikationsserver-Projekt die von \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 einem \b Automatisierungssystem mit BACnet/IP-Schnittstelle\b0  \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 zur Verf\'FCgung gestellt werden, \'FCber den BACnet2B-CON-Treiber aufgeschaltet und durch \b aktives Ausbrowsen im Netzwerk\b0  ausgelesen werden k\'F6nnen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hierzu ist vor Beginn der ICONAG-Projektierungsleistungen der B-CON-Server betriebsbereit im Netzwerk der relevanten BACnet-Ger\'E4te zur Verf\'FCgung zu stellen und die Netzwerk-Routen und ben\'F6tigten Portfreigaben seitens des Auftraggebers einzurichten.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 ICONAG sind die IP-Adressen und BACnet-Device-IDs der relevanten Ger\'E4te zu \'FCbergeben.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Nach dem erfolgreichen "Ausbrowsen" der BACnet-Ger\'E4te wird dem AG eine Datenpunktliste der gescannten Ger\'E4te \'FCbergeben.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Diese ist vom AG anschlie\'DFend auf die f\'FCr das B-CON System relevanten Datenpunkte zu filtern und an ICONAG zur\'FCck zu senden.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Abschlie\'DFend wir die gefilterte Datenpunkt-Konfiguration im B-CON Projekt angelegt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Leistungserbringung erfolgt via Ferneinwahl.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine Ferneinwahlm\'F6glichkeit auf den B-CON Server ist hierzu vom AG zur Verf\'FCgung zu stellen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je BACnet-Ger\'E4t. \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.06.0030\tab\f0\b Datenpunkt\'FCbernahme von Kommunikationstreiber\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Leistung beinhaltet, den Import von Datenpunkten in ein B-CON Server- oder B-CON-Kommunikationsserver-Projekt die von \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 einem \b Automatisierungssystem\b0  \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 zur Verf\'FCgung gestellt werden und entweder \'FCber eine der bereits funktionsbereit eingerichteten X2B-CON-Treiberschnittstellen oder \'FCber einen bereits funktionsbereit eingerichteten OPC Server aufgeschaltet werden k\'F6nnen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b KNX-Schnittstelle(Ger\'E4t) und Modbus-Ger\'E4te:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu importierende Datenpunkte m\'FCssen bereits vollst\'E4ndig in KNX- bzw. Modbus2B-CON angelegt und konfiguriert sein. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b BACnet-Ger\'E4te:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je BACnet-Ger\'E4t ist vom AG vorab eine BACnet-EDE-Datei zu \'FCbergeben. Der Aufbau der EDE-File hat hierbei nach BigEU-Vorgabe zu erfolgen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die zugeh\'F6rigen Object-Types-, Units- und State-Text-Listen sind ebenfalls zu \'FCbergeben.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Properit\'E4re BACnet-Objekte und -Properties werden nicht angelegt.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die EDE-Datei ist vorab vom AG so zu filtern, dass diese nur die f\'FCr die Projektierung der MBE relevanten BACnet-Objekte enth\'E4lt.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine nachtr\'E4gliche Filterung in der MBE-Software ist in dieser Position nichht enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b OPC-Server:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der OPC-Server muss bereits funktionsbereit auf dem MBE-Server eingerichtet sein. Alle f\'FCr das B-CON-Projekt relevanten Ger\'E4te und Datenpunkte m\'FCssen im OPC-Server angelegt und konfiguriert sein und mittels eines unabh\'E4ngigen OPC Client (z.b. Softing Demo Client) auf korrekte Datenkommunikation (schreiben/lesen) gepr\'FCft sein.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Ger\'E4t/OPC-Server-Konfiguration.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.06.0040\tab\f0\b Virtuellen Datenpunkt anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Beinhaltet das Anlegen eines virtuellen Datenpunktes im B-CON Objekteditor.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je virtuellem Datenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.06.0050\tab\f0\b Datenpunktkonfiguration\par
\pard\plain\s0\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Leistung beinhaltet die grundlegende Datenpunktkonfiguration:\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 - Datenpunktskalierung (Formel lesend/schreibend) einrichten\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 - Zuweisen von Einheiten\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 - Beschreibungstexte anpassen\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtungskosten berechnen sich je Datenpunkt.\par
\pard\plain\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.06.0060\tab\f0\b Zuweisung Managementfunktion Alarm-/Messagehandler\par
\pard\plain\s0\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Leistung beinhaltet das Zuweisen eines Datenpunktes zu den B-CON Managementfunktionen Alarm- und Messagehandler.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisung zu Managementfunktionen:\par
\pard\ls36\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisen zum Alarmhandler und/oder Messagehandler\par
\pard\ls36\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtung von bis zu 2 Alarmbedingungen gem\'E4\'DF Kundenvorgabe (bin\'E4r oder Grenzwert)\par
\pard\ls36\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Je Alarmbedingung Zuweisung eines Alarmtextes gem\'E4\'DF Kundenvorgabe\par
\pard\ls36\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisung eines Alarm-VI's\par
\pard\ls36\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Einrichten einer Alarmverz\'F6gerung\par
\pard\ls36\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisen einer Handlungsanweisung\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Hinweis:\par
\pard\ls37\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Diese Position wird ebenfalls f\'FCr die Abonnierung von BACnet Notification Classes angewendet\par
\pard\ls37\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 F\'FCr die Einrichtung von individuellen Alarmbedingungen und Alarmtexten ist vom Kunden vor der Projektierung eine Auflistung mit Alarmdatenpunkten und den zugeh\'F6rigen Alarmbedingungen und Alarmtexten zu \'FCbergeben.\par
\pard\ls37\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 F\'FCr die Zuweisung von Handlungsanweisungen wird das Funktionsmodul Handlungsanweisung ben\'F6tigt.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtungskosten berechnen sich je Datenpunkt.\par
\pard\plain\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.06.0070\tab\f0\b Zuweisung Managementfunktion Historie / Energiemanagement\par
\pard\plain\s0\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Leistung beinhaltet das Zuweisen eines Datenpunktes zu den B-CON Managementfunktionen Historie und Energiemanagement.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisung zu Managementfunktionen:\par
\pard\ls38\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisen zum Historie und/oder Energiemanagement\par
\pard\ls38\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtung der Speichertiefe gem\'E4\'DF Kundenvorgabe\par
\pard\ls38\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtung von bis zu 2 Speicherbedingungen (zeit-, wertebasiert) gem\'E4\'DF Kundenvorgabe\par
\pard\ls38\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuordnung zu einer Historiengruppe\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Hinweis:\par
\pard\ls39\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Diese Position wird ebenfalls f\'FCr die Einrichtung von BACnet TrendLogs angewendet\par
\pard\ls39\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 F\'FCr die Einrichtung von individuellen Speicherbedingungen und Historiengruppen ist vom Kunden vor der Projektierung eine Auflistung mit zu historisierenden Datenpunkten und den zugeh\'F6rigen Speicherbedingungen und Gruppenzuordnungen zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtungskosten berechnen sich je Datenpunkt.\par
\pard\plain\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.06\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektierung Datenpunktkonfiguration\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.07\tab\f0\b B-CON Projektierung Managementfunktionen\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.07.0010\tab\f0\b B-CON "Messagehandler": Grundkonfiguration\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Grundkonfiguration des B-CON Programmmoduls "Messagehandler" vornehmen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\ls40\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Verbindungseinrichtung f\'FCr einen Meldungskanal (E-Mail 1, E-Mail 2 oder SMS) vornehmen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 F\'FCr die Einrichtung einer E-Mail-Verbindung ist ein Mailserver vom Auftrgaggeber beizustellen. Folgende Verbindungsinformationen sind vorab an ICONAG zu \'FCbergeben:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\ls40\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Absender E-Mail-Adresse\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 SMTP-Server\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 SMTP/SSL SMTP Port\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Authentifizierung\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Benutzername\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Passwort\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 F\'FCr die Einrichtung einer SMS-Verbindung sind hierzu vorab folgende Verbindungsinformationen an ICONAG zu \'FCbergeben:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\ls40\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Name\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 COM-Port (wenn nicht von ICONAG konfiguriert)\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 SIM-PIN\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Hinweis: \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 F\'FCr den Meldungsversand via SMS wird eine Lizenz des Moduls "SMS" oder "Multimessage", sowie ein GSM-Gateway samt SIM-Karte (vom AG beizustellen) ben\'F6tigt. Die Lieferung und Einrichtung dieser Leistungen sind in dieser Position nicht enthalten.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20  \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Pauschal je Einrichtung eines Meldungskanals.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.07.0020\tab\f0\b B-CON "Messagehandler": Meldungsempf\'E4nger einrichten\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichten eines neuen Meldungsempf\'E4ngers im B-CON Programmmodul "Messagerhandler" als reinen Meldungsempf\'E4nger oder Meldungskonfiguration eines bestehenden B-CON Benutzers mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls41\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Meldungsempf\'E4nger anlegen\par
\pard\ls41\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuweisen der Meldekan\'E4le\par
\pard\ls41\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 E-Mail-Adresse/Mobilfunknummer (nur SMS) einpflegen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Hinweis: \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 F\'FCr den Meldungsversand via SMS wird eine Lizenz des Moduls "SMS" oder "Multimessage", sowie ein GSM-Gateway samt SIM-Karte (vom AG beizustellen) ben\'F6tigt. Die Lieferung und Einrichtung dieser Leistungen sind in dieser Position nicht enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je einzurichtendem Meldungsempf\'E4nger.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.07.0030\tab\f0\b B-CON "Messagehandler": Meldeprogramm anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichten eines neuen Meldeprogramms im B-CON Programmmodul "Messagerhandler" mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls42\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Name des Meldeprogramms\par
\pard\ls42\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zuordnung der Meldeempf\'E4nger \par
\pard\ls42\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Konfiguration Meldungsnachricht bestehend aus\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Kopfzeile\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldetext\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Ah\'E4nge (nur E-Mail-Versand)\par
\pard\ls42\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zuordnung der Meldeobjekte\par
\pard\ls42\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pr\'FCfung des Meldeprogramms durch Versenden einer Testmeldung\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Voraussetzungen:\par
\pard\ls43\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die ben\'F6tigten Meldungskan\'E4le (E-Mail1, E-Mail2, SMS) m\'FCssen bereits funktionsbereit konfiguriert sein\par
\pard\ls43\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Meldeempf\'E4nger\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab a) m\'FCssen bereits als B-CON Benutzer samt E-Mail- bzw. SMS-Kontakt hinterlegt sein und in der B-CON \tab Berechtigungsvergabe als Meldungsempf\'E4nger freigeschaltet sein.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab b) Reine Meldungsempf\'E4nger m\'FCssen als Meldungsempf\'E4nger bereits im Programmmodul \tab Messagehandler angelegt sein\par
\pard\ls43\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je einzurichtendem Meldungsprogramm sind vom Auftraggeber folgende Informationen an ICONAG zu \'FCbergeben:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldungsempf\'E4nger\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldungstitel (Kopfzeile)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldetext\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Anzuh\'E4ngende Dokumente (nur E-Mail)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldeobjekte\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Hinweis: \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 F\'FCr den Meldungsversand via SMS wird eine Lizenz des Moduls "SMS" oder "Multimessage", sowie ein GSM-Gateway samt SIM-Karte (vom AG beizustellen) ben\'F6tigt. Die Lieferung und Einrichtung dieser Leistungen sind in dieser Position nicht enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je einzurichtendem Meldungsprogramm.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.07.0040\tab\f0\b B-CON "Zeitschaltuhr": Zeitprogramm anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Einrichten eines neuen Zeitprogramms im B-CON Programmmodul "Zeitschaltuhr" mit nachfolgendem Leistungsumfang. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Aktivieren des Zeitprogramms\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zeitprogrammname vergeben\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 G\'FCltigkeitszeitraum festlegen (Datum)\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Festlegen der Zeitprogrammnachf\'FChrung\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuweisen von bis zu 4 Zeitschaltobjekten\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuweisen von bis zu 4 Profilen\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuweisen von bis zu 4 Ausnahmeprogrammen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einem Zeitprogramm k\'F6nnen weitere Zeitschaltobjekte, Profile oder Ausnahmeprogramme zugeordnet werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Folgende Informationen sind vorab vom AG an ICONAG zu \'FCbergeben:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu schaltende Objekte\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zeitprogrammname\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 G\'FCltigkeitszeitraum (Datum)\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu verwendende Profile\par
\pard\ls44\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu hinterlegende Ausnahmeprogramme\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Zeitprogramm.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.07.0050\tab\f0\b B-CON "Zeitschaltuhr": Zuordnung je weitere 4 Zeitschaltobjekte, Profile oder Ausnahmeprogramme\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuordnung von je weiteren 4 Zeitschaltobjekte, Profile oder Ausnahmeprogramme zu einem bereits bestehendem Zeitprogramm.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\ls45\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuweisen von bis zu 4 Zeitschaltobjekten \b oder\par
\pard\ls45\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuweisen von bis zu 4 Profilen \b oder\par
\pard\ls45\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuweisen von bis zu 4 Ausnahmeprogrammen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Folgende Informationen sind vorab vom AG an ICONAG zu \'FCbergeben:\par
\pard\plain\ls46\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls46\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu schaltende Objekte \b oder\par
\pard\ls46\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu verwendende Profile \b oder\par
\pard\ls46\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu hinterlegende Ausnahmeprogramme\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.07.0060\tab\f0\b B-CON "Zeitschaltuhr": Profil anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Einrichten eines neuen Profils im B-CON Programmmodul "Zeitschaltuhr" mit nachfolgendem Leistungsumfang. Das Profil kann anschlie\'DFend in beliebigen Zeitprogrammen verwendet werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls47\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Aktivieren des Profils\par
\pard\ls47\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profilname vergeben\par
\pard\ls47\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 G\'FCltigkeit festlegen (Wochentage)\par
\pard\ls47\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bis zu 4 Zeitkan\'E4le (Zeitschaltpunkte) einrichten\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einem Profil k\'F6nnen weitere Zeitkan\'E4le zugeordnet werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Folgende Informationen sind vorab vom AG an ICONAG zu \'FCbergeben:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls47\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Profilname\par
\pard\ls47\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 G\'FClitigkeit (Wochentage)\par
\pard\ls47\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zeitschaltpunkte\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Profil.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.07.0070\tab\f0\b B-CON "Zeitschaltuhr": Weiterer Zeitkanal\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichten eines weiteren Zeitkanals in einem bereits bestehendem Profil.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Konfiguration der folgenden Zeitkanal-Eigenschaften:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls48\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zeitkanal-Name\par
\pard\ls48\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zeitstempel\par
\pard\ls48\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wert (String) \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die einzurichtenden Informationen sind vorab vom AG an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je weiterem Zeitkanal.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.07.0080\tab\f0\b B-CON "Zeitschaltuhr": Ausnahmeprogramm anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Einrichten eines neuen Ausnahmeprogramms im B-CON Programmmodul "Zeitschaltuhr" mit nachfolgendem Leistungsumfang. Das Ausnahmeprogramm kann anschlie\'DFend in beliebigen Zeitprogrammen verwendet werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls49\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Aktivieren des Ausnahmeprogramms\par
\pard\ls49\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ausnahmeprogrammname vergeben\par
\pard\ls49\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bis zu 12 Ausnahmetage oder -Zeitr\'E4ume einpflegen \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einem Ausnahmeprogramm k\'F6nnen weitere Ausnahmetage zugeordnet werden.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Jede weiteren 12 Ausnahmetage werden mit 8,70 \u8364 ? berechnet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Folgende Informationen sind vorab vom AG an ICONAG zu \'FCbergeben:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls49\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ausnahmeprogrammname\par
\pard\ls49\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Ausnahmetage oder -Zeitr\'E4ume\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Ausnahmeprogramm.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.07.0090\tab\f0\b B-CON "Handlungsanweisungen": Handlungsanweisung anlegen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Einrichten einer neuen Handlungsanweisung im B-CON Programmmodul "Handlungsanweisungen" mit nachfolgendem Leistungsumfang. Die Handlungsanweisung kann anschlie\'DFend beliebigen Alarmdatenpunkten zugeweisen werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls50\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Neue Handlungsanweisung anlegen\par
\pard\ls50\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Name vergeben\par
\pard\ls50\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bis zu 8 Anweisungsschritte einpflegen\par
\pard\ls50\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bis zu 1 PDF-Datei verkn\'FCpfen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Folgende Informationen sind vorab vom AG an ICONAG zu \'FCbergeben:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls50\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Name der Handlungsanweisung\par
\pard\ls50\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu hinterlegende Anweisungen\par
\pard\ls50\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu verkn\'FCpfende PDF-Datei\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 In dieser Position ist das Zuweisen von Handlungsanweisungen zu Alarmobjekten nicht enthalten.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das Zuweisen von Handlungsanweisungen zu Alarmobjekten erfolgt mittels der Position "Zuweisung Managementfunktion Alarm-/Messagehandler".\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Handlungsanweisung.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ul\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.07\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektierung Managementfunktionen\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.08\tab\f0\b B-CON Projektierung EnMS\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.08.0010\tab\f0\b Messstellenverwaltung: Messwertdatenpunkt konfigurieren\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Leistung beinhaltet die Datenpunktkonfiguration und das Einrichten des Datenpunktes im Programmmodul "Messstellenverwaltung" mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\ls51\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Datenpunktkonfiguration vornehmen (Objekteditor: Datentyp, Programmmodulzuordnung)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Einrichtung folgender Parameter:\par
\ls52\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Einheit\par
\ls51\ilvl0{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Skalierung\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Medium\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Messwerttyp\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Speicherzyklus\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Einbauort\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Alarmgrenzen (Wochentag, Wochenende)\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Alarmdatenpunkt\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Je Messwertdatenpunkt ist vom Auftraggeber vorab eine Zuordnungsliste mit den vorgenannten Parametern an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Je Messwertdatenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.08.0020\tab\f0\b Reportverwaltung: Autom. Report anlegen und konfigurieren\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Leistung beinhaltet das Anlegen und Konfigurieren eines EnMS-Reports zum automatisierten Versand via E-Mail im Programmmodul "Reportverwaltung" mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlegen eines (1 St\'FCck) neuen Reports f\'FCr den automatisierten Versand an bis zu 10 E-Mail-Empf\'E4nger \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichtung folgender Parameter:\par
\pard\ls54\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Bezeichung\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Versendeh\'E4ufigkeit\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Uhrzeit\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bereichswahl\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wertedarstellung\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ausgabeformat\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Vorlage\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Messwerte\par
\pard\ls53\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Empf\'E4nger (E-Mail-Adressen)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je anzulegendem Report ist vom Auftraggeber vorab eine Zuordnungsliste mit den vorgenannten Parametern an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je automatisiertem Report.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.08.0030\tab\f0\b Messwertauswertung: Favorit anlegen und konfigurieren\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Leistung beinhaltet das Anlegen und Konfigurieren eines EnMS-Favoriten zur schnellen Auswertung einer spezifischen Auswertungskonfiguration im Programmmodul "Messwertauswertung" mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls55\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlegen eines (1 St\'FCck) neuen Favoriten mit bis zu 8 Messwerten \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichtung folgender Parameter:\par
\pard\ls56\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Favorit-Name\par
\pard\ls56\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Sichtbarkeit\par
\pard\ls55\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Messwerte (bis zu 8 St\'FCck) \par
\pard\ls55\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ausgabedarstellung\par
\pard\ls55\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bereischswahl\par
\pard\ls55\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wertedarstellung\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je anzulegendem Favoriten ist vom Auftraggeber vorab eine Zuordnungsliste mit den vorgenannten Parametern an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je EnMS-Favorit.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.08.0040\tab\f0\b Sankey-Diagramm einrichten mit bis zu 8 Knoten und bis zu 16 Beziehungen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagen und einrichten eines Sankey-Diagramms in den B-CON SysTools nach Vorgabe des AG.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hierzu sind vom AG die anzulegenden Datenpunkte (Knoten) und die zwischen den Knoten herzustellenden Beziehungen mitzuteilen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Knoten:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr virtuelle Knotenpunkte ist seitens des AG der Knotentyp (manueller Wert oder Summe der eingehenden Verbindungen) anzugeben. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr virtuelle Knotenpunkte mit manueller Wertvorgabe ist der entsprechende Wert vom AG vorzugeben.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Knoten kann bei Bedarf zus\'E4tzlich eiene Skalierung gem\'E4\'DF der Formel m * x + b eingerichtet werden, wobei x dem Datenpunktwert entspricht. Ist eine Skalierung einzurichten, ist diese vom AG vorzugeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Beziehungen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr jede Beziehung ist die Flussrichtung anzugeben (z.B. Knoten A zu Knoten B).\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Im Standard erh\'E4lt jede Verbindung seine Wertigkeit (je gr\'F6\'DFer der Wert desto breiter die Liniendarstellung) vom Quellknoten.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bei Bedarf kann eine Verbindung auch den Wert des Zielknotens annehmen. Dies ist vom AG vorzugeben.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der Beziehungswert kann des Weiteren mit einem Faktor multipliziert werden. Dieser ist vom AG anzugeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung der Konfiguration ist enthalten.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.08\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektierung EnMS\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.09\tab\f0\b B-CON Projektierung Anlagenbilder\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Preisanpassung bei Massenminderung\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Kalkulation der Anlagengrafiken beruht auf der im Angebot angegebenen Gesamtmasse aller Anlagengrafiken in Euro. Bei einer Minderung der abzurechnenden Gesamtmasse in Euro kommen folgende Mindermengenzuschl\'E4ge zur Anwendung:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Gesamtmassenminderung Anlagengrafiken in Euro\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 bis zu 5%: ohne Aufschlag\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 ab 5% je Prozentpunkt Massenminderung einen Aufschlag von 0,65% auf die Gesamtmasse in Euro\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Vorlagendateien\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Je Anlagenbild ist vom Auftraggeber eine Vorlagendatei (z.B. Anlagenschema, -Skizze, TRIC- oder RI-Schema) an ICONAG zu \'FCbergeben, in der die zu verwendenden Datenpunkte eindeutig mit Datenpunktnamen verortet sind.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keep\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0010\tab\f0\b Browser-Anlagenbild ohne Grafikelemente erstellen, mit bis zu 10 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) \b\ul ohne\b0\ulnone  Grafikelemente, die z.B. aus einer Dateivorlage zu importieren oder von dieser im Anlagenbild neu zu erstellen sind.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von einfachen Raumbedienfunktionen, Parameterseiten, \'DCbersichtsseiten, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls2\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls2\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 10\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls2\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls2\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls2\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Erstellen und Platzieren von statischen Grafikelementen, die in der Standard-Werkzeugpalette des B-CON Visualisierungseditors enthalten sind, um Gruppierungen oder logische Abgrenzungen zu erstellen, ist enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 ICONAG beh\'E4lt sich vor f\'FCr diese Position eine Teilabrechnung vorzunehmen, sollte es projektspezifisch \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0020\tab\f0\b Browser-Anlagenbild ohne Grafikelemente erstellen, mit bis zu 25 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) \b\ul ohne\b0\ulnone  Grafikelemente, die z.B. aus einer Dateivorlage zu importieren oder von dieser im Anlagenbild neu zu erstellen sind.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von einfachen Raumbedienfunktionen, Parameterseiten, \'DCbersichtsseiten, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls3\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls3\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 25\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls3\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls3\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls3\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Erstellen und Platzieren von statischen Grafikelementen, die in der Standard-Werkzeugpalette des B-CON Visualisierungseditors enthalten sind, um Gruppierungen oder logische Abgrenzungen zu erstellen, ist enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Bedarfsposition ohne Gesamtbetrag\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0030\tab\f0\b Browser-Anlagenbild ohne Grafikelemente erstellen, mit bis zu 50 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) \b\ul ohne\b0\ulnone  Grafikelemente, die z.B. aus einer Dateivorlage zu importieren oder von dieser im Anlagenbild neu zu erstellen sind.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von einfachen Raumbedienfunktionen, Parameterseiten, \'DCbersichtsseiten, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls4\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls4\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 50\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls4\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls4\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls4\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Erstellen und Platzieren von statischen Grafikelementen, die in der Standard-Werkzeugpalette des B-CON Visualisierungseditors enthalten sind, um Gruppierungen oder logische Abgrenzungen zu erstellen, ist enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab nur EP\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Bedarfsposition ohne Gesamtbetrag\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0040\tab\f0\b Browser-Anlagenbild ohne Grafikelemente erstellen, mit bis zu 75 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) \b\ul ohne\b0\ulnone  Grafikelemente, die z.B. aus einer Dateivorlage zu importieren oder von dieser im Anlagenbild neu zu erstellen sind.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zur Verwendung von einfachen Raumbedienfunktionen, Parameterseiten, \'DCbersichtsseiten, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls5\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls5\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 75\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls5\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls5\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls5\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Erstellen und Platzieren von statischen Grafikelementen, die in der Standard-Werkzeugpalette des B-CON Visualisierungseditors enthalten sind, um Gruppierungen oder logische Abgrenzungen zu erstellen, ist enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab nur EP\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0050\tab\f0\b Browser-Anlagenbild mit Grafikelementen (Grafikvorlage) erstellen, mit bis zu 10 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen aus einer \b\ul importfertigen\b0\ulnone  Grafikvorlage. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die importfertige Grafikvorlage ist hierzu vom Auftraggeber im Format .WMF, .PNG, .JPEG oder .BMP und projektspezifischer Aufl\'F6sung und Abmessung zur Verf\'FCgung zu stellen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Vorlagendatei bedarf keiner Nachbearbeitung. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Grundrissvisualisierungen, Raum-Detailbildern, Anlagenbedienung, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls6\ilvl2{\listtext\fs20 1.\tab}\pnstart1\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls6\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Importieren und Ausrichten der Vorlagendatei\par
\pard\ls6\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 10\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls6\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls6\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls6\ilvl2{\listtext\fs20 6.\tab}\li2061\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0060\tab\f0\b Browser-Anlagenbild mit Grafikelementen (Grafikvorlage) erstellen, mit bis zu 25 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen aus einer \b\ul importfertigen\b0\ulnone  Grafikvorlage. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die importfertige Grafikvorlage ist hierzu vom Auftraggeber im Format .WMF, .PNG, .JPEG oder .BMP und projektspezifischer Aufl\'F6sung und Abmessung zur Verf\'FCgung zu stellen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Vorlagendatei bedarf keiner Nachbearbeitung. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Grundrissvisualisierungen, Raum-Detailbildern, Anlagenbedienung, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls7\ilvl2{\listtext\fs20 1.\tab}\pnstart1\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls7\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Importieren und Ausrichten der Vorlagendatei\par
\pard\ls7\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 25\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls7\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls7\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls7\ilvl2{\listtext\fs20 6.\tab}\li2061\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0070\tab\f0\b Browser-Anlagenbild mit Grafikelementen (Grafikvorlage) erstellen, mit bis zu 50 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen aus einer \b\ul importfertigen\b0\ulnone  Grafikvorlage. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die importfertige Grafikvorlage ist hierzu vom Auftraggeber im Format .WMF, .PNG, .JPEG oder .BMP und projektspezifischer Aufl\'F6sung und Abmessung zur Verf\'FCgung zu stellen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Vorlagendatei bedarf keiner Nachbearbeitung. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Grundrissvisualisierungen, Raum-Detailbildern, Anlagenbedienung, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls8\ilvl2{\listtext\fs20 1.\tab}\pnstart1\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls8\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Importieren und Ausrichten der Vorlagendatei\par
\pard\ls8\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 50\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls8\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls8\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls8\ilvl2{\listtext\fs20 6.\tab}\li2061\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0080\tab\f0\b Browser-Anlagenbild mit Grafikelementen (Grafikvorlage) erstellen, mit bis zu 75 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen aus einer \b\ul importfertigen\b0\ulnone  Grafikvorlage. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die importfertige Grafikvorlage ist hierzu vom Auftraggeber im Format .WMF, .PNG, .JPEG oder .BMP und projektspezifischer Aufl\'F6sung und Abmessung zur Verf\'FCgung zu stellen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Vorlagendatei bedarf keiner Nachbearbeitung. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Grundrissvisualisierungen, Raum-Detailbildern, Anlagenbedienung, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls9\ilvl2{\listtext\fs20 1.\tab}\pnstart1\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls9\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Importieren und Ausrichten der Vorlagendatei\par
\pard\ls9\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 75\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls9\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls9\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls9\ilvl2{\listtext\fs20 6.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0090\tab\f0\b Browser-Anlagenbild mit Grafikelementen (ohne Grafikvorlage) erstellen, mit bis zu 10 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen die im B-CON Visualisierungseditor nach Vorgabe projektspezifisch erstellt werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hierzu sind vom Auftraggeber Anlagen-Schemata oder detaillierte Beschreibungen vorzulegen, die als Grundlagen zu Grafikerstellung dienen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Raum-Detailbildern, Anlagenbildern, etc.\par
\pard\plain\pnstart1\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls10\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls10\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen der Grafikelemente\par
\pard\ls10\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 10\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls10\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls10\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls10\ilvl2{\listtext\fs20 6.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0100\tab\f0\b Browser-Anlagenbild mit Grafikelementen (ohne Grafikvorlage) erstellen, mit bis zu 25 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen die im B-CON Visualisierungseditor nach Vorgabe projektspezifisch erstellt werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hierzu sind vom Auftraggeber Anlagen-Schemata oder detaillierte Beschreibungen vorzulegen, die als Grundlagen zu Grafikerstellung dienen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Raum-Detailbildern, Anlagenbildern, etc.\par
\pard\plain\pnstart1\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls11\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls11\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen der Grafikelemente\par
\pard\ls11\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 25\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls11\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls11\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls11\ilvl2{\listtext\fs20 6.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0110\tab\f0\b Browser-Anlagenbild mit Grafikelementen (ohne Grafikvorlage) erstellen, mit bis zu 50 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen die im B-CON Visualisierungseditor nach Vorgabe projektspezifisch erstellt werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hierzu sind vom Auftraggeber Anlagen-Schemata oder detaillierte Beschreibungen vorzulegen, die als Grundlagen zu Grafikerstellung dienen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Raum-Detailbildern, Anlagenbildern, etc.\par
\pard\plain\pnstart1\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls12\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls12\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen der Grafikelemente\par
\pard\ls12\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 50\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls12\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls12\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls12\ilvl2{\listtext\fs20 6.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0120\tab\f0\b Browser-Anlagenbild mit Grafikelementen (ohne Grafikvorlage) erstellen, mit bis zu 75 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen die im B-CON Visualisierungseditor nach Vorgabe projektspezifisch erstellt werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hierzu sind vom Auftraggeber Anlagen-Schemata oder detaillierte Beschreibungen vorzulegen, die als Grundlagen zu Grafikerstellung dienen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Raum-Detailbildern, Anlagenbildern, etc.\par
\pard\plain\pnstart1\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls13\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls13\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen der Grafikelemente\par
\pard\ls13\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 75\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls13\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls13\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls13\ilvl2{\listtext\fs20 6.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0130\tab\f0\b Browser-Dashboard ohne Grafikelemente erstellen, mit bis zu 8 Charts\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\cf15\cb0 Erstellen einer Browser-Dashboard-Seite (HTML5) ohne Grafikelemente, die z.B. aus einer Dateivorlage zu importieren oder von dieser im Anlagenbild\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\cf15\cb0 neu zu erstellen sind.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f4\fs20\cf15\cb0  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f0\fs20\cf15\cb0 Zur Verwendung von Energie- und Trenddaten-Dashboards etc.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f4\fs20\cf15\cb0  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f0\fs20\cf15\cb0 Je Dashboard-Seite sind in dieser Position folgende Leistungen enthalten:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f4\fs20\cf15\cb0  \par
\pard\ls57\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f0\fs20\cf15\cb0 Erstellen einer Dashboardeite gem\'E4\'DF Pflichtenheft oder Kundenabsprache\par
\pard\ls57\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\cf15\cb0 Platzieren von bis zu 8 Chartcontrols\par
\pard\ls57\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\cf15\cb0 Je Chart Verkn\'FCpfung mit bis zu 8 Trenddatenpunkten\par
\pard\ls57\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\cf15\cb0 Dashboard-Seite in die Navigationshierarchie einordnen\par
\pard\ls57\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\cf15\cb0 Dashboard-Seite auf Funktion pr\'FCfen\par
\pard\ls57\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\cf15\cb0 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f4\fs20\cf15\cb0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) Eindeutung mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\f4\fs20\cf15\cb0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\cf15\cb0 Eine einmalige \'DCberarbeitung der Dashboard-Seite ist in dieser Position enthalten.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f4\fs20\cf15\cb0  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\f0\fs20\cf15\cb0 Pauschal je Dashboard-Seite.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0140\tab\f0\b Browser-Bediendialog (PopUp) spezifisch, mit bis zu 5 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Bediendialogs (HTML5) \b\ul ohne\b0\ulnone  Grafikelemente, der als PopUp-Dialog \'FCber ein bestehendes Browser-Anlagenbild aufgerufen werden kann. Dieser Bediendialog ist f\'FCr eine spezifische Bedienfunktion\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone  zu erstellen, die nicht dynamisch f\'FCr mehrere identische R\'E4ume oder Anlagenkomponenten verwendet werden kann. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone Auch kommt diese Position bei mehreren identischen Bediendialogen zur Anwendung, wenn kein eindeutiges, interpretierbares und durchg\'E4ngig korrekt angewendetes Kennzeichnungssystem f\'FCr die Datenpunktbenamung vorliegt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Raumbedienfunktionen, Detailbedienung von Anlagenkomponenten, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls14\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Browser-Bediendialog gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls14\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 5\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls14\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1x Schaltfl\'E4che zum Aufruf des Bediendialoges in vorhandenem Browser-Anlagenbild platzieren \par
\pard\ls14\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Browser-Bediendialog auf Funktion pr\'FCfen\par
\pard\ls14\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlag\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Erstellen und Platzieren von statischen Grafikelementen, die in der Standard-Werkzeugpalette des B-CON Visualisierungseditors enthalten sind, um Gruppierungen oder logische Abgrenzungen zu erstellen, ist enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Bediendialoges ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Bediendialog.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0150\tab\f0\b Browser-Bediendialog (PopUp) spezifisch, mit bis zu 10 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Bediendialogs (HTML5) \b\ul ohne\b0\ulnone  Grafikelemente, der als PopUp-Dialog \'FCber ein bestehendes Browser-Anlagenbild aufgerufen werden kann. Dieser Bediendialog ist f\'FCr eine spezifische Bedienfunktion\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone  zu erstellen, die nicht dynamisch f\'FCr mehrere identische R\'E4ume oder Anlagenkomponenten verwendet werden kann. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone Auch kommt diese Position bei mehreren identischen Bediendialogen zur Anwendung, wenn kein eindeutiges, interpretierbares und durchg\'E4ngig korrekt angewendetes Kennzeichnungssystem f\'FCr die Datenpunktbenamung vorliegt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Raumbedienfunktionen, Detailbedienung von Anlagenkomponenten, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls15\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Browser-Bediendialog gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls15\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 10\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls15\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1x Schaltfl\'E4che zum Aufruf des Bediendialoges in vorhandenem Browser-Anlagenbild platzieren \par
\pard\ls15\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Browser-Bediendialog auf Funktion pr\'FCfen\par
\pard\ls15\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlag\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Erstellen und Platzieren von statischen Grafikelementen, die in der Standard-Werkzeugpalette des B-CON Visualisierungseditors enthalten sind, um Gruppierungen oder logische Abgrenzungen zu erstellen, ist enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Bediendialoges ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Bediendialog.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Bedarfsposition ohne Gesamtbetrag\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0160\tab\f0\b Browser-Bediendialog (PopUp) dynamisch, mit bis zu 5 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Bediendialogs (HTML5) \b\ul ohne\b0\ulnone  Grafikelemente, der als PopUp-Dialog \'FCber ein bestehendes Browser-Anlagenbild aufgerufen werden kann. Dieser Bediendialog ist f\'FCr Bedienfunktionen zu erstellen, die f\'FCr mehrere identische R\'E4ume oder Anlagenkomponenten verwendet werden kann. Die Datenpunktverkn\'FCpfungen werden hierzu mit dynamisch ersetzbaren Platzhalterzeichen versehen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone Ein eindeutiges, interpretierbares und durchg\'E4ngig korrekt angewendetes Kennzeichnungssystem f\'FCr die Datenpunktbenamung ist hierf\'FCr Voraussetzung.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Raumbedienfunktionen, Detailbedienung von Anlagenkomponenten, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls16\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Browser-Bediendialog gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls16\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 5\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls16\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichten der Dynamikfunktion\par
\pard\ls16\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Browser-Bediendialog auf Funktion pr\'FCfen\par
\pard\ls16\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlag\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Erstellen und Platzieren von statischen Grafikelementen, die in der Standard-Werkzeugpalette des B-CON Visualisierungseditors enthalten sind, um Gruppierungen oder logische Abgrenzungen zu erstellen, ist enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Bediendialoges ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Bediendialog.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab nur EP\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Bedarfsposition ohne Gesamtbetrag\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0170\tab\f0\b Browser-Bediendialog (PopUp) dynamisch, mit bis zu 10 Anzeige- oder Bedienelementen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Bediendialogs (HTML5) \b\ul ohne\b0\ulnone  Grafikelemente, der als PopUp-Dialog \'FCber ein bestehendes Browser-Anlagenbild aufgerufen werden kann. Dieser Bediendialog ist f\'FCr Bedienfunktionen zu erstellen, die f\'FCr mehrere identische R\'E4ume oder Anlagenkomponenten verwendet werden kann. Die Datenpunktverkn\'FCpfungen werden hierzu mit dynamisch ersetzbaren Platzhalterzeichen versehen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone Ein eindeutiges, interpretierbares und durchg\'E4ngig korrekt angewendetes Kennzeichnungssystem f\'FCr die Datenpunktbenamung ist hierf\'FCr Voraussetzung.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Raumbedienfunktionen, Detailbedienung von Anlagenkomponenten, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls17\ilvl2{\listtext\fs20 1.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Browser-Bediendialog gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls17\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen von bis zu \b\ul 10\b0\ulnone  dynamischen Anzeige- oder Bedienelementen\par
\pard\ls17\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichten der Dynamikfunktion\par
\pard\ls17\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Browser-Bediendialog auf Funktion pr\'FCfen\par
\pard\ls17\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlag\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Erstellen und Platzieren von statischen Grafikelementen, die in der Standard-Werkzeugpalette des B-CON Visualisierungseditors enthalten sind, um Gruppierungen oder logische Abgrenzungen zu erstellen, ist enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Bediendialoges ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Bediendialog.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab nur EP\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Bedarfsposition ohne Gesamtbetrag\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0180\tab\f0\b Aufruf dynamischer Browser-Bediendialog\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Platzieren und Verkn\'FCpfen einer Schaltfl\'E4che zum Aufruf eines dynamischen Popup-Dialogs.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Einrichten der Dynamikfunktion.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Bediendialog.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab nur EP\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0190\tab\f0\b Browser-Anlagenbild: weiteres Anzeige- oder Bedienelement\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Leistung beinhaltet das Platzieren und Verkn\'FCpfen eines weiteren Anzeige- oder Bedienelementes in einem bereits bestehenden Browser-Anlagenbild oder -Bediendialog.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die zu verkn\'FCpfenden Datenpunkte m\'FCssen bereits in der B-CON Objektliste vorhanden sein.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Je Anzeige- oder Bedienelement.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0200\tab\f0\b Browser-Anlagenbild \'FCberarbeiten\par
\pard\plain\s0\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Leistung beinhaltet das \'DCberarbeiten/Anpassen eines existierenden B-CON Anlagenbildes an einen aktuellen Anlagen- und Systemstatus in Absprache mit dem Kunden oder nach Vorlage eines Pflichtenheftes.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0210\tab\f0\b B-CON Projekt. Anlagenbild umbauen a. HTML5-WebVi\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Leistung beinhaltet den Umbau eines existierenden klassischen B-CON-VI's auf ein B-CON-Web-VI. Hierbei erfolgt keine Anpassung des Anlagenbild-Designs. Es erfolgt lediglich ein Ersetzen der klassischen Controls durch B-CON-Webcontrols.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bitte beachten Sie, dass aufgrund der unterschiedlichen Technologien das\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Aussehen sowie die Bedienung der Anzeige- und Bedienelemente unter\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Umst\'E4nden nicht 1-zu-1 abgebildet werden k\'F6nnen und sich hier in der\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Handhabung bei der Browserbedienung Unterschiede ergeben.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.09.0220\tab\f0\b Entwicklungsleistungen f\'FCr projektspez. Sonderanpassungen nach Tagessatz\line\par
\pard\plain\s0\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Zu verrechnender Tagessatz f\'FCr Entwicklungsdienstleistungen durch\par
\pard\li1701\ri1701\sa113\tx1701\wpparflg64\keepn\keep\plain\fs20 den Hersteller bzw. einen offiziellen ICONAG-Systempartner.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.09\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektierung Anlagenbilder\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.10\tab\f0\b B-CON Projektierung Anlagenbilder nach Anlagentyp\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\ul Hinweise zu Positionen Anlagenbilder nach Anlagentypen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 In den nachfolgenden Positionen sind folgende Leistungen enthalten, wenn im jeweiligen Positionstext davon keine abweichenden Angaben gemacht werden:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Datenpunktimport:\par
\ls58\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Import von Datenpunkten im Umfang der im Artikeltext angegebenen Menge in ein B-CON Server- oder B-CON-Kommunikationsserver-Projekt, die von einem Automatisierungssystem zur Verf\'FCgung gestellt werden und entweder \'FCber eine der im Artikeltext angegebenen, bereits funktionsbereit eingerichteten, X2B-CON-Treiberschnittstellen oder, wenn angegeben, \'FCber einen bereits funktionsbereit eingerichteten OPC Server aufgeschaltet werden k\'F6nnen.\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 KNX-Schnittstelle(Ger\'E4t) und Modbus-Ger\'E4te: Zu importierende Datenpunkte m\'FCssen bereits vollst\'E4ndig in KNX- bzw. Modbus2B-CON angelegt und konfiguriert sein. \par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 BACnet-Ger\'E4te: Je BACnet-Ger\'E4t ist vom AG vorab eine BACnet-EDE-Datei zu \'FCbergeben. Der Aufbau der EDE-File hat hierbei nach BigEU-Vorgabe zu erfolgen. Die zugeh\'F6rigen Object-Types-, Units- und State-Text-Listen sind ebenfalls zu \'FCbergeben. Properit\'E4re BACnet-Objekte und -Properties werden nicht angelegt. Die EDE-Datei ist vorab vom AG so zu filtern, dass diese nur die f\'FCr die Projektierung der MBE relevanten BACnet-Objekte enth\'E4lt. Eine nachtr\'E4gliche Filterung in der MBE-Software ist in dieser Position nicht enthalten.\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 OPC-Server: Der OPC-Server muss bereits funktionsbereit auf dem MBE-Server eingerichtet sein. Alle f\'FCr das B-CON-Projekt relevanten Ger\'E4te und Datenpunkte m\'FCssen im OPC-Server angelegt und konfiguriert sein und mittels eines unabh\'E4ngigen OPC Client (z.b. Softing Demo Client) auf korrekte Datenkommunikation (schreiben/lesen) gepr\'FCft sein.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Datenpunktkonfiguration:\par
\ls59\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Falls erforderlich: \par
{\listtext\f6\fs20 \'B7\tab}\li2781\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Datenpunktskalierung (Formel lesend/schreibend) einrichten\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Zuweisen von Einheiten\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b Zuweisung Managementfunktion Alarm-/Messagehandler:\par
\ls59\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Falls erforderlich: \par
{\listtext\f6\fs20 \'B7\tab}\li2781\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Zuweisen zum Alarmhandler und/oder Messagehandler\par
\pard\ls59\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\ri1701\tx8789\plain\fs20 Einrichtung von bis zu 2 Alarmbedingungen gem\'E4\'DF Kundenvorgabe (bin\'E4r oder Grenzwert)\par
{\listtext\f6\fs20 \'B7\tab}\tx8789\plain\fs20 Einrichten einer Alarmverz\'F6gerung\par
{\listtext\f6\fs20 \'B7\tab}\tx8789\plain\fs20 BACnet: Abonnierung von BACnet Notification Classes\par
\pard\plain\li2421\ri1701\tx8789\plain\fs20\par
\li1701\tx8789\wpparid0\plain\fs20\b Zuweisung Managementfunktion Historie / Energiemanagement:\par
\ls59\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx8789\wpparid0\plain\fs20 Falls erforderlich:\par
{\listtext\f6\fs20 \'B7\tab}\li2781\fi0\tx8789\plain\fs20 Zuweisen zum Historie und/oder Energiemanagement\par
{\listtext\f6\fs20 \'B7\tab}\tx8789\plain\fs20 Einrichtung der Speichertiefe gem\'E4\'DF Kundenvorgabe\par
{\listtext\f6\fs20 \'B7\tab}\tx8789\plain\fs20 Einrichtung von bis zu 2 Speicherbedingungen (zeit-, wertebasiert) gem\'E4\'DF Kundenvorgabe\par
{\listtext\f6\fs20 \'B7\tab}\tx8789\plain\fs20 BACnet: Einrichtung von BACnet TrendLogs\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Anlagenbilderstellung:\par
\ls60\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen die im B-CON Visualisierungseditor nach Vorgabe projektspezifisch erstellt werden. Gem\'E4\'DF Pflichtenheft oder Kundenabsprache.\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Erstellen der Grafikelemente\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Platzieren und verkn\'FCpfen von dynamischen Anzeige- oder Bedienelementen im Umfang der angegebenen Datenpunktmenge\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
{\listtext\f6\fs20 \'B7\tab}\li2061\fi0\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b Dokumentation:\par
\ls61\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Bildkopie in die B-CON Dokumentation einbinden\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b Folgende Voraussetzungen sind seitens des Auftraggebers zu erbringen:\par
\ls62\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Vom Auftraggeber sind Anlagen-Schemata oder detaillierte Beschreibungen vorzulegen, die als Grundlagen zu Grafikerstellung dienen.\par
\ls60\ilvl0{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in voriger oder einer separaten Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit den zu verkn\'FCpfenden Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b Unkonfigurierte BACnet-Systeme:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 BACnet-Systeme gelten dann als unkofniguriert, wenn eine der nachfolgenden Voraussetzungen in der BACnet-Projektierung eines aufzuschaltenden Ger\'E4tes nicht gegeben ist. In diesem Fall werden diese Systeme wie Modbus-/KNX-/OPC-Systeme behandelt und berechnet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\ls63\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Alle f\'FCr die MBE relevanten BACnet Objekte verf\'FCgen \'FCber einen eindeutigen Object_Name. Ist seitens des Bauherrn/Betriebers eine Bentzeradressierungssystem vorgegeben ist dieses im Object_Name eingepflegt.\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Die Eigenschaft "Description" ist mit einem aussagekr\'E4ftigen Klartext bef\'FCllt. \par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 bei analogen Datenpunkten (Analog Value/Input/Output) ist die Eigenschaft "Unit" ensprechend der \'FCbermittelten Wertigkeit in der Eigenschaft "Present-Value" gepflegt. Es werden ausschlie\'DFlich Unit-Codes gem\'E4\'DF BACnet-Standard verwendet.\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 bei analogen Datenpunkten (Analog Value/Input/Output) entpricht die Wertskalierung in der Eigenschaft "Present-Value" der angegebenen Einheit in der Eigenschaft "Unit".\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 bei Datenpunkten vom Typ Binary (Value/Input/Output) sind die Eigenschaften "Active_Text" und "Inactive_Text" sinnvoll gem\'E4\'DF der Datenpunktfunktion bef\'FCllt\par
{\listtext\f6\fs20 \'B7\tab}\li2061\fi0\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 bei Datenpunkten vom Typ Multistate (Value/Input/Output) ist die Eigenschaft "State_Texts" sinnvoll gem\'E4\'DF der Datenpunktfunktion sowie der m\'F6glichen Zust\'E4nde bef\'FCllt\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 F\'FCr das Alarm- und Eventmanagement sind die Funktionen gem\'E4\'DF BACnet-Standard (Intrinsic Reporting/Event Enrollement + Notification Classes) durchg\'E4ngig anzuwenden\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Es sind alle Meldungsklassen, gem\'E4\'DF Absprache mit dem Bauherrn/Betreiber, angelegt\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 BACnet-Objekte, die auf Grund einer Alarm- oder Grenzwertbedingung eine Meldung auf der Managmant- und Bedieneinrichtung generieren sollen, verf\'FCgen \'FCber eine entsprechende intrinsiche Alarmkonfiguration und sind einer Notification_Class zugeordnet bzw. werden durch ein Event_Enrollment Objekt \'FCberwacht.\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Zeitschaltfunktionen sind ausschlie\'DFlich mittels BACnet Schedule- und Calendar-Objekten in den Automationsstationen ausgef\'FChrt.\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Datenpunkte, f\'FCr die eine l\'FCckenlose (24/7) Aufzeichnung von Trenddaten gefordert ist, ist mittels BACnet Trendlog-Objekten eine Pufferung der Trenddaten auf der Automationsstation eingerichtet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Abrechnung:\par
\ls60\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Es erfolgt keine R\'FCckverg\'FCtung oder Anrechnung von Datenpunkten, wenn die im Artikel angegebenen maximale Datenpunktanzahl nicht erreicht wird.\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Teilabrechnungen vorbehalten.\par
{\listtext\f6\fs20 \'B7\tab}\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Abrechnung erfolgt nach Aufma\'DF.\par
\pard\plain\li1701\ri1701\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keep\par
\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0010\tab\f0\b Raumlufttechnische Anlage (Modbus/KNX/OPC) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0020\tab\f0\b Raumlufttechnische Anlage (Modbus/KNX/OPC) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0030\tab\f0\b Raumlufttechnische Anlage (Modbus/KNX/OPC) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0040\tab\f0\b Raumlufttechnische Anlage (Modbus/KNX/OPC) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0050\tab\f0\b Luftverteil- und Brandschutzklappen-Schema (Modbus/KNX/OPC) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0060\tab\f0\b Luftverteil- und Brandschutzklappen-Schema (Modbus/KNX/OPC) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0070\tab\f0\b Luftverteil- und Brandschutzklappen-Schema (Modbus/KNX/OPC) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0080\tab\f0\b Luftverteil- und Brandschutzklappen-Schema (Modbus/KNX/OPC) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0090\tab\f0\b W\'E4rmeerzeugende-/K\'E4lteerzeugende Anlage (Modbus/KNX/OPC) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0100\tab\f0\b W\'E4rme-/K\'E4lteverteilung mit bis zu 2 Heizkreisen (Modbus/KNX/OPC) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0110\tab\f0\b W\'E4rme-/K\'E4lteverteilung mit bis zu 4 Heizkreisen (Modbus/KNX/OPC) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0120\tab\f0\b Parameterseite als Popup-Dialog (Modbus/KNX/OPC) mit bis zu 5 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0130\tab\f0\b Parameterseite als Popup-Dialog (Modbus/KNX/OPC) mit bis zu 15 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0140\tab\f0\b Parameterseite als Popup-Dialog (Modbus/KNX/OPC) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0150\tab\f0\b Raumfunktionen in Grundrissdarstellung (Modbus/KNX/OPC) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0160\tab\f0\b Raumfunktionen in Grundrissdarstellung (Modbus/KNX/OPC) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0170\tab\f0\b Raumfunktionen in Grundrissdarstellung (Modbus/KNX/OPC) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0180\tab\f0\b Raumfunktionen in Grundrissdarstellung (Modbus/KNX/OPC) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0190\tab\f0\b Raumdetailbild als Popup-Dialog (Modbus/KNX/OPC) mit bis zu 5 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0200\tab\f0\b Raumdetailbild als Popup-Dialog (Modbus/KNX/OPC) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0210\tab\f0\b Raumdetailbild als Popup-Dialog (Modbus/KNX/OPC) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s0\li1701\ri1701\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keep\par
\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0220\tab\f0\b Raumlufttechnische Anlage (BACnet) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0230\tab\f0\b Raumlufttechnische Anlage (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0240\tab\f0\b Raumlufttechnische Anlage (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0250\tab\f0\b Raumlufttechnische Anlage (BACnet) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0260\tab\f0\b Luftverteil- und Brandschutzklappen-Schema (BACnet) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0270\tab\f0\b Luftverteil- und Brandschutzklappen-Schema (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0280\tab\f0\b Luftverteil- und Brandschutzklappen-Schema (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0290\tab\f0\b Luftverteil- und Brandschutzklappen-Schema (BACnet) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0300\tab\f0\b W\'E4rmeerzeugende-/K\'E4lteerzeugende Anlage (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0310\tab\f0\b W\'E4rmeerzeugende-/K\'E4lteerzeugende Anlage (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0320\tab\f0\b W\'E4rme-/K\'E4lteverteilung mit bis zu 2 Heizkreisen (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0330\tab\f0\b W\'E4rme-/K\'E4lteverteilung mit bis zu 4 Heizkreisen (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0340\tab\f0\b Sonstige Anlagetechnik der W\'E4rme-/K\'E4lteerzeugung (BACnet) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0350\tab\f0\b Sonstige Anlagetechnik der W\'E4rme-/K\'E4lteerzeugung (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0360\tab\f0\b Sonstige Anlagetechnik der W\'E4rme-/K\'E4lteerzeugung (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0370\tab\f0\b Sonstige Anlagetechnik der W\'E4rme-/K\'E4lteerzeugung (BACnet) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0380\tab\f0\b Sanit\'E4re Anlagentechnik (BACnet) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0390\tab\f0\b Sanit\'E4re Anlagentechnik (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0400\tab\f0\b Sanit\'E4re Anlagentechnik (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0410\tab\f0\b Sanit\'E4re Anlagentechnik (BACnet) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0420\tab\f0\b Parameterseite als Popup-Dialog (BACnet) mit bis zu 5 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0430\tab\f0\b Parameterseite als Popup-Dialog (BACnet) mit bis zu 15 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0440\tab\f0\b Parameterseite als Popup-Dialog (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0450\tab\f0\b Liegenschafts\'FCbersicht (BACnet) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0460\tab\f0\b Liegenschafts\'FCbersicht (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0470\tab\f0\b Liegenschafts\'FCbersicht (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0480\tab\f0\b Liegenschafts\'FCbersicht (BACnet) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0490\tab\f0\b Geb\'E4ude\'FCbersicht (BACnet) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0500\tab\f0\b Geb\'E4ude\'FCbersicht (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0510\tab\f0\b Geb\'E4ude\'FCbersicht (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0520\tab\f0\b Geb\'E4ude\'FCbersicht (BACnet) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0530\tab\f0\b Raumfunktionen in Grundrissdarstellung (BACnet) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0540\tab\f0\b Raumfunktionen in Grundrissdarstellung (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0550\tab\f0\b Raumfunktionen in Grundrissdarstellung (BACnet) mit bis zu 50 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0560\tab\f0\b Raumfunktionen in Grundrissdarstellung (BACnet) mit bis zu 75 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0570\tab\f0\b Raumdetailbild als Popup-Dialog (BACnet) mit bis zu 5 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0580\tab\f0\b Raumdetailbild als Popup-Dialog (BACnet) mit bis zu 10 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.10.0590\tab\f0\b Raumdetailbild als Popup-Dialog (BACnet) mit bis zu 25 DP\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 wie zuvor beschrieben, jedoch f\'FCr den im Artikeltext angegebenen Anlagentyp, die angegebenen Treiberschnittstelle/n sowie f\'FCr die maximal angegebene Datenpunktanzahl.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Anlagenbild.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.10\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b B-CON Projektierung Anlagenbilder nach Anlagentyp\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.11\tab\f0\b BACnet-Projektierung nach VDI 3814\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Preisanpassung bei Massenminderung\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Kalkulation der Anlagengrafiken beruht auf der im Angebot angegebenen Gesamtmasse aller Anlagengrafiken in Euro. Bei einer Minderung der abzurechnenden Gesamtmasse in Euro kommen folgende Mindermengenzuschl\'E4ge zur Anwendung:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Gesamtmassenminderung Anlagengrafiken in Euro\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 bis zu 5%: ohne Aufschlag\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 ab 5% je Prozentpunkt Massenminderung einen Aufschlag von 0,65% auf die Gesamtmasse in Euro\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\sa0\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Vorlagendateien\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Je Anlagenbild ist vom Auftraggeber eine Vorlagendatei (z.B. Anlagenschema, -Skizze, TRIC- oder RI-Schema) an ICONAG zu \'FCbergeben, in der die zu verwendenden Datenpunkte eindeutig mit Datenpunktnamen verortet sind.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keep\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.11.0010\tab\f0\b B-CON Projektierung - "Kommunikation Ein- / Ausgabefunktion" \line nach VDI 3814 - Leistungsteil 7 Managementfunktionen\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Leistung beinhaltet, den Import von einfachen BACnet-Objekttypen, wie\par
\pard\ls64\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bin\'E4re Objekte\par
\pard\ls64\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Analoge Objekte\par
\pard\ls64\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Multistate Objekte\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 in ein B-CON Server- oder B-CON-Kommunikationsserver-Projekt die von \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 einem \b Automatisierungssystem\b0  \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 zur Verf\'FCgung gestellt werden und \'FCber eine bereits funktionsbereit eingerichtete BACnet2B-CON-Treiberschnittstellen aufgeschaltet werden k\'F6nnen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b BACnet-Ger\'E4te:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je BACnet-Ger\'E4t ist vom AG vorab eine BACnet-EDE-Datei zu \'FCbergeben. Der Aufbau der EDE-File hat hierbei nach BigEU-Vorgabe zu erfolgen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die zugeh\'F6rigen Object-Types-, Units- und State-Text-Listen sind ebenfalls zu \'FCbergeben.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Properit\'E4re BACnet-Objekte und -Properties werden nicht angelegt.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die EDE-Datei ist vorab vom AG so zu filtern, dass diese nur die f\'FCr die Projektierung der MBE relevanten BACnet-Objekte enth\'E4lt.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine nachtr\'E4gliche Filterung in der MBE-Software ist in dieser Position nicht enthalten.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20 Einrichtungskosten berechnen sich je Datenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.11.0020\tab\f0\b B-CON Projektierung - "Kommunikation Block- / Datei" \line nach VDI 3814 - Leistungsteil 7 Managementfunktionen\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Leistung beinhaltet, den Import von komplexen BACnet-Objekttypen, wie\par
\pard\ls65\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Device Objekte\par
\pard\ls65\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Schedule Objekte\par
\pard\ls65\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 NotificationClass Objekte\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 in ein B-CON Server- oder B-CON-Kommunikationsserver-Projekt die von \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 einem \b Automatisierungssystem\b0  \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 zur Verf\'FCgung gestellt werden und \'FCber eine bereits funktionsbereit eingerichtete BACnet2B-CON-Treiberschnittstellen aufgeschaltet werden k\'F6nnen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b BACnet-Ger\'E4te:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je BACnet-Ger\'E4t ist vom AG vorab eine BACnet-EDE-Datei zu \'FCbergeben. Der Aufbau der EDE-File hat hierbei nach BigEU-Vorgabe zu erfolgen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die zugeh\'F6rigen Object-Types-, Units- und State-Text-Listen sind ebenfalls zu \'FCbergeben.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Properit\'E4re BACnet-Objekte und -Properties werden nicht angelegt.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die EDE-Datei ist vorab vom AG so zu filtern, dass diese nur die f\'FCr die Projektierung der MBE relevanten BACnet-Objekte enth\'E4lt.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine nachtr\'E4gliche Filterung in der MBE-Software ist in dieser Position nicht enthalten.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\b\par
\pard\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20 Einrichtungskosten berechnen sich je Datenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.11.0030\tab\f0\b B-CON Projektierung - "Ereignis-Langzeitspeicherung"\line nach VDI 3814 - Leistungsteil 7 Managementfunktionen\line\par
\pard\plain\s0\li1701\ri1701\tx8789\wpparid0\keepn\keep\plain\fs20\b Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx8789\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisung zu Managementfunktionen:\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisen zum Alarmhandler und/oder Messagehandler\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtung von bis zu 2 Alarmbedingungen gem\'E4\'DF Kundenvorgabe (bin\'E4r oder Grenzwert)\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Je Alarmbedingung Zuweisung eines Alarmtextes gem\'E4\'DF Kundenvorgabe\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisung eines Alarm-VI's\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Einrichten einer Alarmverz\'F6gerung\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisen einer Handlungsanweisung\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Hinweis:\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\wpparid0\keepn\keep\plain\fs20 Diese Position wird ebenfalls f\'FCr die Abonnierung von BACnet Notification Classes angewendet\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 F\'FCr die Einrichtung von individuellen Alarmbedingungen und Alarmtexten ist vom Kunden vor der Projektierung eine Auflistung mit Alarmdatenpunkten und den zugeh\'F6rigen Alarmbedingungen und Alarmtexten zu \'FCbergeben.\par
\pard\ls66\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 F\'FCr die Zuweisung von Handlungsanweisungen wird das Funktionsmodul Handlungsanweisung ben\'F6tigt.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20 Einrichtungskosten berechnen sich je Datenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.11.0040\tab\f0\b B-CON Projektierung - "Historisierung in Datenbank"\line nach VDI 3814 - Leistungsteil 7 Managementfunktionen\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg64\keepn\keep\plain\fs20\b Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg64\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Leistung beinhaltet das Zuweisen eines Datenpunktes zu den B-CON Managementfunktionen Historie und Energiemanagement.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisung zu Managementfunktionen:\par
\pard\ls67\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuweisen zum Historie und/oder Energiemanagement\par
\pard\ls67\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtung der Speichertiefe gem\'E4\'DF Kundenvorgabe\par
\pard\ls67\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Einrichtung von bis zu 2 Speicherbedingungen (zeit-, wertebasiert) gem\'E4\'DF Kundenvorgabe\par
\pard\ls67\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Zuordnung zu einer Historiengruppe\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx8789\keepn\keep\plain\fs20 Hinweis:\par
\pard\ls67\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 Diese Position wird ebenfalls f\'FCr die Einrichtung von BACnet TrendLogs angewendet\par
\pard\ls67\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx8789\keepn\keep\plain\fs20 F\'FCr die Einrichtung von individuellen Speicherbedingungen und Historiengruppen ist vom Kunden vor der Projektierung eine Auflistung mit zu historisierenden Datenpunkten und den zugeh\'F6rigen Speicherbedingungen und Gruppenzuordnungen zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx8789\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx8789\keepn\keep\plain\fs20 Einrichtungskosten berechnen sich je Datenpunkt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.11.0050\tab\f0\b B-CON Projektierung - "Grafik / Anlagenbild" \line nach Vorlage nach VDI 3814 - Leistungsteil 8 Bedienfunktionen\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\b Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen eines Browser-Anlagenbildes (HTML5) mit Hintergrund-Grafikelementen aus einer \b\ul importfertigen\b0\ulnone  Grafikvorlage. \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die importfertige Grafikvorlage ist hierzu vom Auftraggeber im Format .WMF, .PNG, .JPEG oder .BMP und projektspezifischer Aufl\'F6sung und Abmessung zur Verf\'FCgung zu stellen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Vorlagendatei bedarf keiner Nachbearbeitung. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zur Verwendung von Grundrissvisualisierungen, Raum-Detailbildern, Anlagenbedienung, etc.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls18\ilvl2{\listtext\fs20 1.\tab}\pnstart1\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild gem\'E4\'DF Pflichtenheft oder Kundenabsprache erstellen\par
\pard\ls18\ilvl2{\listtext\fs20 2.\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Importieren und Ausrichten der Vorlagendatei\par
\pard\ls18\ilvl2{\listtext\fs20 3.\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild in die Navigationshierarchie einordnen\par
\pard\ls18\ilvl2{\listtext\fs20 4.\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anlagenbild auf Funktion pr\'FCfen\par
\pard\ls18\ilvl2{\listtext\fs20 5.\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Erstellen einer Bildkopie im Format .JPEG oder .PNG zur Kundenvorlage\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine einmalige \'DCberarbeitung des Anlagenbildes ist in dieser Position enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je Anlagenbild.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.11.0060\tab\f0\b B-CON Projektierung - "Dynamische Einblendung"\line nach VDI 3814 - Leistungsteil 8 Bedienfunktionen\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg64\keepn\keep\plain\fs20\b Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg64\keepn\keep\plain\fs20\b\par
\pard\li2061\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Platzieren und verkn\'FCpfen eines (1 St\'FCck) \ulnone dynamischen Anzeige- oder Bedienelementes auf einem bereits existierenden B-CON Anlagenbild.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\ulnone Es kommen nur Anzeige- und Bedienelemente zum Einsatz die in der Standard-Controlpalette \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\ulnone von B-CON enthalten sind.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die im Anlagenbild zu verwendenden Datenpunkte sind vom Auftraggeber in einer Vorlagendatei (z.B. Anlagenschema oder -Skizze) eindeutig mit Datenpunktnamen zu verorten und an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\ulnone\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\ulnone Je dynamischer Einblendung.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.11.0070\tab\f0\b B-CON Projektierung - "Ereignis-Anweisungstext" nach VDI 3814 - Leistungsteil 8 Bedienfunktionen\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\b Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Einrichten einer neuen Handlungsanweisung im B-CON Programmmodul "Handlungsanweisungen" mit nachfolgendem Leistungsumfang. Die Handlungsanweisung kann anschlie\'DFend beliebigen Alarmdatenpunkten zugeweisen werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls68\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Neue Handlungsanweisung anlegen\par
\pard\ls68\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Name vergeben\par
\pard\ls68\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bis zu 8 Anweisungsschritte einpflegen\par
\pard\ls68\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bis zu 1 PDF-Datei verkn\'FCpfen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Folgende Informationen sind vorab vom AG an ICONAG zu \'FCbergeben:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls68\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Name der Handlungsanweisung\par
\pard\ls68\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu hinterlegende Anweisungen\par
\pard\ls68\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu verkn\'FCpfende PDF-Datei\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 In dieser Position ist das Zuweisen von Handlungsanweisungen zu Alarmobjekten nicht enthalten.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das Zuweisen von Handlungsanweisungen zu Alarmobjekten erfolgt mittels der Position "Zuweisung Managementfunktion Alarm-/Messagehandler".\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal je Handlungsanweisung.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.11.0080\tab\f0\b B-CON Projektierung - "Nachricht an externe Stelle"\line nach VDI 3814 - Leistungsteil 8 Bedienfunktionen\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\ul B-CON "Messagehandler": Meldungsempf\'E4nger einrichten\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\b\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichten eines neuen Meldungsempf\'E4ngers im B-CON Programmmodul "Messagerhandler" als reinen Meldungsempf\'E4nger oder Meldungskonfiguration eines bestehenden B-CON Benutzers mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Meldungsempf\'E4nger anlegen\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Zuweisen der Meldekan\'E4le\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 E-Mail-Adresse/Mobilfunknummer (nur SMS) einpflegen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Hinweis: \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 F\'FCr den Meldungsversand via SMS wird eine Lizenz des Moduls "SMS" oder "Multimessage", sowie ein GSM-Gateway samt SIM-Karte (vom AG beizustellen) ben\'F6tigt. Die Lieferung und Einrichtung dieser Leistungen sind in dieser Position nicht enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\ul B-CON "Messagehandler": Meldeprogramm anlegen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einrichten eines neuen Meldeprogramms im B-CON Programmmodul "Messagerhandler" mit folgendem Leistungsumfang:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Name des Meldeprogramms\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zuordnung der Meldeempf\'E4nger \par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Konfiguration Meldungsnachricht bestehend aus\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Kopfzeile\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldetext\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Ah\'E4nge (nur E-Mail-Versand)\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zuordnung der Meldeobjekte\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pr\'FCfung des Meldeprogramms durch Versenden einer Testmeldung\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Voraussetzungen:\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die ben\'F6tigten Meldungskan\'E4le (E-Mail1, E-Mail2, SMS) m\'FCssen bereits funktionsbereit konfiguriert sein\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Meldeempf\'E4nger\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab a) m\'FCssen bereits als B-CON Benutzer samt E-Mail- bzw. SMS-Kontakt hinterlegt sein und in der B-CON \tab Berechtigungsvergabe als Meldungsempf\'E4nger freigeschaltet sein.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab b) Reine Meldungsempf\'E4nger m\'FCssen als Meldungsempf\'E4nger bereits im Programmmodul \tab Messagehandler angelegt sein\par
\pard\ls69\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je einzurichtendem Meldungsprogramm sind vom Auftraggeber folgende Informationen an ICONAG zu \'FCbergeben:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldungsempf\'E4nger\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldungstitel (Kopfzeile)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldetext\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Anzuh\'E4ngende Dokumente (nur E-Mail)\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\tab - Meldeobjekte\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Hinweis: \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 F\'FCr den Meldungsversand via SMS wird eine Lizenz des Moduls "SMS" oder "Multimessage", sowie ein GSM-Gateway samt SIM-Karte (vom AG beizustellen) ben\'F6tigt. Die Lieferung und Einrichtung dieser Leistungen sind in dieser Position nicht enthalten.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je einzurichtendem Meldungsempf\'E4nger und Meldungsprogramm.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.11\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b BACnet-Projektierung nach VDI 3814\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.12\tab\f0\b Projektierung (Pauschal)\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.12.0010\tab\f0\b B-CON Projektierung (Pauschal)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Folgende Leistungen sind in dieser Position enthalten:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Pflichtenheft\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\tab\b0 (   ) Erstellung Pflichtenheft gem\'E4\'DF B-CON Standard\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\tab (   ) Erstellung Pflichtenheft gem\'E4\'DF Vorgabe\par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Projektmanagement\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\tab _____ Stck Teilnahme an Projektbesprechungen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\tab __1__ Stck Dokumentation (digital)\par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b Grundkonfiguration Management- und  Bedieneinrichtung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON Benutzer anlegen \par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b B-CON Projektierung X2B-CON-Treiber\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b\tab\b0 (   ) BACnet2B-CON: Grundkonfiguration\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck KNX2B-CON: KNX-Schnittstelle anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck KNX2B-CON: Datenpunkt anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Modbus2B-CON: Modbus-Ger\'E4t anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Modbus2B-CON: Datenpunkt anlegen\par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b B-CON Projektierung OPC-Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck OPC-Server: Installation und Grundkonfiguration\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck OPC-Server: Kommunikationsteilnehmer anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck OPC-Server: Datenpunkt anlegen\par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b B-CON Projektierung Datenpunktkonfiguration\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Datenpunkt\'FCbernahme von B-CON Kommunikationsserver\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Datenpunkt\'FCbernahme von BACnet2B-CON durch "Online-Browsing"\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Datenpunkt\'FCbernahme von Kommunikationstreiber\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Datenpunktkonfiguration\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Zuweisung Managementfunktion Alarm-/Messagehandler\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Zuweisung Managementfunktion Historie / Energiemanagement\par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b B-CON Projektierung Managementfunktionen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab (   ) B-CON "Messagehandler": Grundkonfiguration\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON "Messagehandler": Meldungsempf\'E4nger einrichten\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON "Messagehandler": Meldeprogramm anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON "Zeitschaltuhr": Zeitprogramm anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON "Zeitschaltuhr": Zuordnung je weitere 4 Zeitschaltobjekte, Profile oder Ausnahmeprogramme\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON "Zeitschaltuhr": Profil anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON "Zeitschaltuhr": Weiterer Zeitkanal\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON "Zeitschaltuhr": Ausnahmeprogramm anlegen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck B-CON "Handlungsanweisungen": Handlungsanweisung anlegen\par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b B-CON Projektierung EnMS\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Messstellenverwaltung: Messwertdatenpunkt konfigurieren\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Reportverwaltung: Autom. Report anlegen und konfigurieren\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Messwertauswertung: Favorit anlegen und konfigurieren\par
\ls70\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\b B-CON Projektierung Anlagenbilder\par
\pard\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Vorlagendateien:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Je Anlagenbild ist vom Auftraggeber eine Vorlagendatei (z.B. Anlagenschema, -Skizze, TRIC- oder RI-Schema) an ICONAG zu \'FCbergeben, in der die zu verwendenden Datenpunkte eindeutig mit Datenpunktnamen verortet sind.\par
\pard\plain\li2421\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\li1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild ohne Grafikelemente erstellen, mit bis zu 10 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild ohne Grafikelemente erstellen, mit bis zu 25 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild ohne Grafikelemente erstellen, mit bis zu 50 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild ohne Grafikelemente erstellen, mit bis zu 75 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild mit Grafikelementen (Grafikvorlage) erstellen, mit bis zu 10 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild mit Grafikelementen (Grafikvorlage) erstellen, mit bis zu 25 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild mit Grafikelementen (Grafikvorlage) erstellen, mit bis zu 50 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild mit Grafikelementen (Grafikvorlage) erstellen, mit bis zu 75 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild mit Grafikelementen (ohne Grafikvorlage) erstellen, mit bis zu 10 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild mit Grafikelementen (ohne Grafikvorlage) erstellen, mit bis zu 25 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild mit Grafikelementen (ohne Grafikvorlage) erstellen, mit bis zu 50 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Anlagenbild mit Grafikelementen (ohne Grafikvorlage) erstellen, mit bis zu 75 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Dashboard ohne Grafikelemente erstellen, mit bis zu 8 Charts\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Bediendialog (PopUp) spezifisch, mit bis zu 5 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Bediendialog (PopUp) spezifisch, mit bis zu 10 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Bediendialog (PopUp) dynamisch, mit bis zu 5 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Browser-Bediendialog (PopUp) dynamisch, mit bis zu 10 Anzeige- oder Bedienelementen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\tab _____ Stck Aufruf dynamischer Browser-Bediendialog\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Hinweis:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Wir behalten uns vor, im Falle von Mehrleistungen \'FCber 5% des kalkulatorischen Dienstleistungspreises diese gem\'E4\'DF der Einheitspreise nachzuberechnen. Etwaige Minderleistungen einzelner Positionen werden dabei ber\'FCcksichtigt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Pauschal.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.12\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Projektierung (Pauschal)\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.13\tab\f0\b Inbetriebnahme und Funktionstest\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.13.0010\tab\f0\b Probebetrieb\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 14-t\'E4giger Probebetrieb, in dem die Funktionsweise der B-CON Management- und Bedieneinrichtung sowie kundenspezifische PlugIns stichprobenartig mittels Ferneinwahl durch einen ICONAG-Systemtechniker \'FCberwacht werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Seitens des AG ist durchgehend eine Internetverbindung sowie eine Ferneinwahlm\'F6glichkeit auf das B-CON System bereitzustellen.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 6 h\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.13.0020\tab\f0\b 1:1 Datenpunkttest\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr jeden Datenpunkt ist ein 1:1-Datenpunkttest in Zusammenarbeit mit dem Auftragnehmer auf Automationbsebene durchzuf\'FChren.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Jeder Datenpunkt ist von der Feldebene (Sensor/Aktor) bis in die Management- und Bedieneinrichtung auf plausible Funktion und korrekte Verwendung im zugeh\'F6rigen Anlagenbild zu pr\'FCfen und zu protokolieren.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr die Kalkulation sind XXXX Datenpunkte zu ber\'FCcksichtigen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Seitens des Errichters der MBE kann der 1:1-Datenpunkttest auch durch Beistellung eines geeigneten Softwaretools erfolgen, dass es dem Auftragnehmer auf Automationsbene erm\'F6glicht die Datenpunkttests autonom und zeitgleich mit mehreren Mitarbeitern durchzuf\'FChren. Der Umfang der Protokollierung und die G\'FCte der Datenpunktests d\'FCrfen hierdurch jedoch keinesfalls geringer ausfallen. Ebenso darf hierdurch kein Mehraufwand f\'FCr den Auftragnehmer auf Automationsebene entstehen. Im Gegenteil sollte der Einsatz eines Softwaretools eine effizientere Durchf\'FChrung des 1:1-Datenpunkttests erm\'F6glichen.\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das Softwaretool ist vorab dem Aufraggeber vorzustellen und zu demonstrieren. Die Zulassung des Softwaretools obliegt dem Auftraggeber.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.13.0030\tab\f0\b Inbetriebnahme und Funktionstest vor Ort\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Inbetriebnahme der Management- und Bedieneinrichtung vor Ort in Terminabsprache mit dem Fachplaner und dem Bediener. Kosten f\'FCr \'DCbernachtung und Anfahrt sind in dieser Position mit zu ber\'FCcksichtigen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs22\par
\pard\li1701\ri1701\sa113\tx1701\wpparid0\plain\fs20 Zzgl. Reisekosten, \'DCbernachtung und Spesen.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 Tag\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.13.0040\tab\f0\b Anfahrtpauschale ICONAG-Systemtechniker\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Idar-Oberstein => \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Pauschale deckt folgende Kosten ab:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1. An- und Abreisezeit f\'FCr die reisende Person\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 2. Fahrzeug-, Bahn- oder Flugkosten f\'FCr die An- und Abreise\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.13.0050\tab\f0\b\'DCbernachtungen inkl. Spesen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Deckt die \'DCbernachtungskosten inkl. Spesen eines ICONAG-Systemtechnikers ab.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je \'DCbernachtung.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Dienstleistungen via Ferneinwahl\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Dienstleistungen f\'FCr Inbetriebnahmen, Funktionstests oder Benutzerweinweisungen werden via Ferneinwahl durchgef\'FChrt. Der B-CON Projekt-Server, sowie alle mit der Inbetriebnahme einzurichtenden Bedienplatz-Rechner sind bauseits so zu ert\'FCchtigen, dass diese via Ferneinwahl von ICONAG erreicht werden k\'F6nnen (Internetzugang, z.B. via DSL, LTE, etc.). \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr Funktionstests mit unterlagerten Automatisierungssystemen muss ein Techniker des Kunden vor Ort zur Verf\'FCgung stehen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Im Standard erfolgt die Einwahl seitens ICONAG mittels des Fernwartungstools "TeamViewer". Sollte die Nutzung von TeamViewer seitens des Kunden nicht zugelassen sein, ist bauseits eine alternative, gleichwertige Einwahlm\'F6glichkeit mit ICONAG abzustimmen und bereit zu stellen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Vor-Ort-Termine werden durch ICONAG nur nach vorheriger Absprache und nach Erfordernis durchgef\'FChrt. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keep\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.13.0060\tab\f0\b Inbetriebnahme und Funktionstest via Ferneinwahl\par
\pard\plain\s0\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Tagessatz f\'FCr die Inbetriebnahme der Management- und Bedieneinrichtung via Ferneinwahl in Terminabsprache mit dem Fachplaner und dem Bediener. \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.13.0070\tab\f0\b Inbetriebnahme und Funktionstest via Ferneinwahl (Stundensatz)\par
\pard\plain\s0\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Stundensatz f\'FCr die Inbetriebnahme der Management- und Bedieneinrichtung via Ferneinwahl in Terminabsprache mit dem Fachplaner und dem Bediener. \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.13\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Inbetriebnahme und Funktionstest\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.14\tab\f0\b Wartung und Softwarepflege\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Preisanpassung von Softwarepflege- und Update-Vereinbarungen (SPUV)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Bitte beachten Sie, dass bei einer Beauftragung etwaiger Optional- bzw. Alternativ-Positionen, eine Anpassung der Kalkulationsgrundlage der Softwarepflege- und Updatevereinbarung erfolgt.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Ebenso nachtr\'E4glich erworbene Erweiterungen der Erstlizenzen (wie z.B. Datenpunktupgrade, zus\'E4tzliche Funktionsmodule und native Schnittstellen von ICONAG), werden automatisch Bestandteil dieser SPUV. Die Nachberechnung der Verg\'FCtung erfolgt erstmalig f\'FCr die Zeit ab Auslieferung der jeweiligen Erweiterung von Beginn des Folgemonats bis zum Jahresende.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Ab dem Folgejahr wird die SPUV f\'FCr Erstlizenzen und Erweiterungen zu Beginn des Kalenderjahres f\'FCr volle 12 Monate im Voraus berechnet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Preisgleitklausel: F\'FCr diesen Laufzeitvertrag gilt eine Preisgleitklausel. Die Preisanpassung erfolgt kalenderj\'E4hrlich jeweils zum 1. Januar in H\'F6he der Preisentwicklung der Erzeugerpreise f\'FCr Dienstleistungen in Deutschland. Grundlage der Preisanpassung ist der Prozentsatz, der vom Statistischen Bundesamt f\'FCr das 3. Quartal des Vorjahres festgestellt wurde. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 ---------------------------------------------------------------------------------------\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Grundposition\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0010\tab\f0\b Softwarepflege- und Update-Vereinbarung (SPUV), 120 Monate\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Softwarepflege- und Update- Vereinbarung f\'FCr bestehende B-CON Serverlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1. Pr\'E4ambel: Der Lizenznehmer der ICONAG-Softwareprodukte sowie die ICONAG m\'F6chten eine m\'F6glichst lange Nutzungsdauer des durch den Lizenznehmer erworbenen ICONAG Software-Systems sicherstellen. Darum haben beide Parteien ein Interesse daran, dass die lizenzierten Softwareprodukte weiter entwickelt werden und vereinbaren diese Softwarepflegeund Update-Vereinbarung (im Folgenden SPUV). Mit dieser SPUV unterst\'FCtzt der Lizenznehmer die Weiterentwicklung der Software und erwirbt gleichzeitig das Recht, die jeweils neueste Version der eingesetzten ICONAG-Software anzufordern. Die SPUV wird mit dem Erst-Erwerb der ICONAG-Lizenzen abgeschlossen. Ein sp\'E4terer Abschluss f\'FChrt zu einer Nachberechnung.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 2. Updates und Leistungen: ICONAG passt die ICONAG Produkte entsprechend dem technischen Fortschritt, den W\'FCnschen der Anwender sowie der Erfahrung der ICONAG an. Dies f\'FChrt zu Versionsupdates, Service-Releases und Bug-Fixes an den durch den Lizenznehmer lizenzierten ICONAG-Softwareprodukten. Diese stellt ICONAG dem Lizenznehmer kostenlos per Datentr\'E4ger (z. B. USB-Stick, DVD) oder Download zur Verf\'FCgung. Eine Installation ist im Rahmen dieser Vereinbarung nicht geschuldet. ICONAG macht dabei keine Zusagen bez\'FCglich der Zyklen von Versionsupdates und Servicereleases. Sobald ein Update ausgeliefert ist, tritt es hinsichtlich der Nutzungsrechte an die Stelle der alten Programmversion.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 3. Laufzeit: Bei Neukauf einer Lizenz ist die SPUV im 1. Jahr nach Erwerb kostenfrei. Die SPUV wird nach Ablauf des 1. kostenfreien Jahres f\'FCr die vereinbarte Vertragslaufzeit geschlossen (3, 5 oder 10 Jahre). Sie verl\'E4ngert sich automatisch um drei Jahre, wenn sie nicht mit einer Frist von 3 Monaten zum Vertragsende gek\'FCndigt wird.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 4. Verg\'FCtung: F\'FCr die getroffene Vereinbarung berechnet ICONAG dem Lizenznehmer j\'E4hrlich 18% der gesamten Lizenzkosten f\'FCr ICONAG-Software, also 1,50% pro Monat. Die Berechnung der Verg\'FCtung erfolgt auf Basis der jeweils aktuell g\'FCltigen Preisliste. Die Verg\'FCtung f\'FCr SPUV wird erstmals nach Ablauf des 1. kostenfreien Jahres bis zum Ende des laufenden Kalenderjahres berechnet. In den Folgejahren wird die Verg\'FCtung jeweils zu Beginn des Kalenderjahres f\'FCr volle 12 Monate im Voraus berechnet.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die nachtr\'E4glich erworbenen Erweiterungen der Erstlizenzen (wie z.B. Datenpunktupgrade, zus\'E4tzliche Funktionsmodule und native Schnittstellen von ICONAG), werden automatisch Bestandteil dieser SPUV. Die Nachberechnung der Verg\'FCtung erfolgt erstmalig f\'FCr die Zeit ab Auslieferung der jeweiligen Erweiterung von Beginn des Folgemonats bis zum Jahresende.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ab dem Folgejahr wird die SPUV f\'FCr Erstlizenzen und Erweiterungen zu Beginn des Kalenderjahres f\'FCr volle 12 Monate im Voraus berechnet.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Lizenznehmer ohne laufende SPUV k\'F6nnen nachtr\'E4glich eine SPUV abschlie\'DFen. Beim nachtr\'E4glichen Abschluss der SPUV entf\'E4llt das 1. kostenfreie Jahr. Berechnungsbeginn ist in diesem Fall der 01.01.2017. F\'FCr den Zeitraum zwischen 01.01.2017 und Abschluss der SPUV wird zus\'E4tzlich ein Nachberechnungszuschlag in H\'F6he von 50% der j\'E4hrlichen SPUV Verg\'FCtung f\'E4llig. Der Nachberechnungszeitraum ist auf maximal 4 Jahre begrenzt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Preisgleitklausel: F\'FCr diesen Laufzeitvertrag gilt eine Preisgleitklausel. Die Preisanpassung erfolgt kalenderj\'E4hrlich jeweils zum 1. Januar in H\'F6he der Preisentwicklung der Erzeugerpreise f\'FCr Dienstleistungen in Deutschland. Grundlage der Preisanpassung ist der Prozentsatz, der vom Statistischen Bundesamt f\'FCr das 3. Quartal des Vorjahres festgestellt wurde. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis B-CON Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 -\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 12% pro Jahr\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Berechnungszeitraum\b0\ulnone :\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (10 Jahre)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Eine Beauftragung etwaiger Alternativ-Positionen hat eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Anpassung der Kalkulationsgrundlage der SPuV zur Folge.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 120 Monate. Die Rechnungsstellung erfolgt j\'E4hrlich.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal pro Monat\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 Mon\tab ......................\tab ..............................\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Alternativposition 1 zu Grundposition 02.14.0010\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0020\tab\f0\b Softwarepflege- und Update-Vereinbarung (SPUV), 60 Monate\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie in vorheriger Position beschrieben, jedoch Laufzeit: 60 Monate.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis B-CON Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 15% pro Jahr\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Berechnungszeitraum:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (5 Jahre)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Eine Beauftragung etwaiger Alternativ-Positionen hat eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Anpassung der Kalkulationsgrundlage der SPuV zur Folge\i0 .\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 60 Monate. Die Rechnungsstellung erfolgt j\'E4hrlich.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal pro Monat.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 Mon\tab ......................\tab nur EP\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Alternativposition 2 zu Grundposition 02.14.0010\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0030\tab\f0\b Softwarepflege- und Update-Vereinbarung (SPUV), 36 Monate\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie in vorheriger Position beschrieben, jedoch Laufzeit: 36 Monate.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis B-CON Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 18% pro Jahr\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Berechnungszeitraum:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (3 Jahre)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Eine Beauftragung etwaiger Alternativ-Positionen hat eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Anpassung der Kalkulationsgrundlage der SPuV zur Folge.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 36 Monate. Die Rechnungsstellung erfolgt j\'E4hrlich.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal pro Monat.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 Mon\tab ......................\tab nur EP\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Alternativposition 1 zu Grundposition 02.14.0010\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0040\tab\f0\b Softwarepflege- und Update-Vereinbarung (SPUV), 12 Monate\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie in vorheriger Position beschrieben, jedoch Laufzeit: 12 Monate.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis B-CON Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 21% pro Jahr\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Berechnungszeitraum:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (1 Jahr)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Eine Beauftragung etwaiger Alternativ-Positionen hat eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Anpassung der Kalkulationsgrundlage der SPuV zur Folge\i0 .\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 12 Monate. Die Rechnungsstellung erfolgt j\'E4hrlich.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal pro Monat.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 Mon\tab ......................\tab nur EP\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Grundposition\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0050\tab\f0\b Softwarepflege- und Update-Vereinbarung (SPUV), 12 Monate\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Softwarepflege- und Update- Vereinbarung f\'FCr bestehende B-CON Serverlizenz\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1. Pr\'E4ambel: Der Lizenznehmer der ICONAG-Softwareprodukte sowie die ICONAG m\'F6chten eine m\'F6glichst lange Nutzungsdauer des durch den Lizenznehmer erworbenen ICONAG Software-Systems sicherstellen. Darum haben beide Parteien ein Interesse daran, dass die lizenzierten Softwareprodukte weiter entwickelt werden und vereinbaren diese Softwarepflegeund Update-Vereinbarung (im Folgenden SPUV). Mit dieser SPUV unterst\'FCtzt der Lizenznehmer die Weiterentwicklung der Software und erwirbt gleichzeitig das Recht, die jeweils neueste Version der eingesetzten ICONAG-Software anzufordern. Die SPUV wird mit dem Erst-Erwerb der ICONAG-Lizenzen abgeschlossen. Ein sp\'E4terer Abschluss f\'FChrt zu einer Nachberechnung.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 2. Updates und Leistungen: ICONAG passt die ICONAG Produkte entsprechend dem technischen Fortschritt, den W\'FCnschen der Anwender sowie der Erfahrung der ICONAG an. Dies f\'FChrt zu Versionsupdates, Service-Releases und Bug-Fixes an den durch den Lizenznehmer lizenzierten ICONAG-Softwareprodukten. Diese stellt ICONAG dem Lizenznehmer kostenlos per Datentr\'E4ger (z. B. USB-Stick, DVD) oder Download zur Verf\'FCgung. Eine Installation ist im Rahmen dieser Vereinbarung nicht geschuldet. ICONAG macht dabei keine Zusagen bez\'FCglich der Zyklen von Versionsupdates und Servicereleases. Sobald ein Update ausgeliefert ist, tritt es hinsichtlich der Nutzungsrechte an die Stelle der alten Programmversion.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 3. Laufzeit: Bei Neukauf einer Lizenz ist die SPUV im 1. Jahr nach Erwerb kostenfrei. Die SPUV wird nach Ablauf des 1. kostenfreien Jahres f\'FCr die vereinbarte Vertragslaufzeit geschlossen (3, 5 oder 10 Jahre). Sie verl\'E4ngert sich automatisch um drei Jahre, wenn sie nicht mit einer Frist von 3 Monaten zum Vertragsende gek\'FCndigt wird.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 4. Verg\'FCtung: F\'FCr die getroffene Vereinbarung berechnet ICONAG dem Lizenznehmer j\'E4hrlich 18% der gesamten Lizenzkosten f\'FCr ICONAG-Software, also 1,50% pro Monat. Die Berechnung der Verg\'FCtung erfolgt auf Basis der jeweils aktuell g\'FCltigen Preisliste. Die Verg\'FCtung f\'FCr SPUV wird erstmals nach Ablauf des 1. kostenfreien Jahres bis zum Ende des laufenden Kalenderjahres berechnet. In den Folgejahren wird die Verg\'FCtung jeweils zu Beginn des Kalenderjahres f\'FCr volle 12 Monate im Voraus berechnet.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die nachtr\'E4glich erworbenen Erweiterungen der Erstlizenzen (wie z.B. Datenpunktupgrade, zus\'E4tzliche Funktionsmodule und native Schnittstellen von ICONAG), werden automatisch Bestandteil dieser SPUV. Die Nachberechnung der Verg\'FCtung erfolgt erstmalig f\'FCr die Zeit ab Auslieferung der jeweiligen Erweiterung von Beginn des Folgemonats bis zum Jahresende.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ab dem Folgejahr wird die SPUV f\'FCr Erstlizenzen und Erweiterungen zu Beginn des Kalenderjahres f\'FCr volle 12 Monate im Voraus berechnet.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Lizenznehmer ohne laufende SPUV k\'F6nnen nachtr\'E4glich eine SPUV abschlie\'DFen. Beim nachtr\'E4glichen Abschluss der SPUV entf\'E4llt das 1. kostenfreie Jahr. Berechnungsbeginn ist in diesem Fall der 01.01.2017. F\'FCr den Zeitraum zwischen 01.01.2017 und Abschluss der SPUV wird zus\'E4tzlich ein Nachberechnungszuschlag in H\'F6he von 50% der j\'E4hrlichen SPUV Verg\'FCtung f\'E4llig. Der Nachberechnungszeitraum ist auf maximal 4 Jahre begrenzt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Preisgleitklausel: F\'FCr diesen Laufzeitvertrag gilt eine Preisgleitklausel. Die Preisanpassung erfolgt kalenderj\'E4hrlich jeweils zum 1. Januar in H\'F6he der Preisentwicklung der Erzeugerpreise f\'FCr Dienstleistungen in Deutschland. Grundlage der Preisanpassung ist der Prozentsatz, der vom Statistischen Bundesamt f\'FCr das 3. Quartal des Vorjahres festgestellt wurde. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis B-CON Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 - \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 21% pro Jahr\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Berechnungszeitraum:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (1 Jahr)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Eine Beauftragung etwaiger Alternativ-Positionen hat eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Anpassung der Kalkulationsgrundlage der SPuV zur Folge\i0 .\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 12 Monate. Die Rechnungsstellung erfolgt j\'E4hrlich.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal pro Kalenderjahr\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Alternativposition 1 zu Grundposition 02.14.0050\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0060\tab\f0\b Softwarepflege- und Update-Vereinbarung (SPUV), 36 Monate\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie in vorheriger Position beschrieben, jedoch Laufzeit: 36 Monate.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis B-CON Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 18% pro Jahr\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Berechnungszeitraum:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (3 Jahre)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Eine Beauftragung etwaiger Alternativ-Positionen hat eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Anpassung der Kalkulationsgrundlage der SPuV zur Folge\i0 .\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 36 Monate. Die Rechnungsstellung erfolgt j\'E4hrlich.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal pro Kalenderjahr\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab nur EP\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Alternativposition 1 zu Grundposition 02.14.0050\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0070\tab\f0\b Softwarepflege- und Update-Vereinbarung (SPUV), 60 Monate\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie in vorheriger Position beschrieben, jedoch Laufzeit: 60 Monate.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis B-CON Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 15% pro Jahr\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Berechnungszeitraum:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (5 Jahre)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Eine Beauftragung etwaiger Alternativ-Positionen hat eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Anpassung der Kalkulationsgrundlage der SPuV zur Folge\i0 .\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 60 Monate. Die Rechnungsstellung erfolgt j\'E4hrlich.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal pro Kalenderjahr\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab nur EP\par
\pard\plain\s4\li0\fi0\ri0\sb0\sa0\ql\vertalt\keepn\keep\fs16\b *** Alternativposition 2 zu Grundposition 02.14.0050\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0080\tab\f0\b Softwarepflege- und Update-Vereinbarung (SPUV), 120 Monate\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie in vorheriger Position beschrieben, jedoch Laufzeit: 120 Monate.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis B-CON Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 -\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 12% pro Jahr\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b\ul Berechnungszeitraum:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 (10 Jahre)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Eine Beauftragung etwaiger Alternativ-Positionen hat eine\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\i Anpassung der Kalkulationsgrundlage der SPuV zur Folge\i0 .\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 120 Monate. Die Rechnungsstellung erfolgt j\'E4hrlich.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20  \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal pro Kalenderjahr\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab nur EP\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0090\tab\f0\b Systemwartung per Ferneinwahl pro Jahr\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Unter die Systemwartung per Ferneinwahl fallen folgende Leistungen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Pr\'FCfung des Release-Standes, Einspielen von Service-Releases und Bug-Fixes \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - \'DCberpr\'FCfung und Pflege der Datenbanken des ICONAG-Systems\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - \'DCberpr\'FCfung der Kommunikation mit unterlagerten Systemen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - \'DCberpr\'FCfung von Windows-Sicherheitsupdates \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Die Leistungen werden per Ferneinwahl durchgef\'FChrt und umfassen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 1x B-CON Server\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 0x B-CON Bedienclient\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Basierend auf Softwarepflege- und Update-Vereinbarung - Anhang C.\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal pro Kalenderjahr\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0100\tab\f0\b Hotline-Support-Vereinbarung nach Aufwand\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Unter den System-Support fallen folgende Leistungen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Anwender-Unterst\'FCtzung und Beratung beim Betrieb des Geb\'E4udeleitsystems \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Analyse und Unterst\'FCtzung bei Systemst\'F6rungen inkl. qualifizierter R\'FCckmeldungen f\'FCr Probleml\'F6sungen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Unterst\'FCtzung bei der Fehleranalyse in unterlagerten Systemen inkl. etwaiger Abstimmungen mit anderen Lieferanten  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Support bei Netzwerkproblemen inkl. etwaiger Abstimmungen mit der IT-Abteilung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Vorschlag und Umsetzung von vorl\'E4ufigen Probleml\'F6sungen (\u8222 ?Workarounds\u8220 ?) im Fall von kritischen St\'F6rungen oder    Problemen, die programmatisch nicht gel\'F6st werden k\'F6nnen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Durchf\'FChrung kleinerer System- und Funktionserweiterungen per Ferneiwahl\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Basierend auf Softwarepflege- und Update-Vereinbarung - Anhang D.\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Abrechnung erfolgt nach Aufwand, im 30 Minuten-Takt\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 h\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0110\tab\f0\b Hotline-Support-Vereinbarung 5 Std.\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Unter den System-Support fallen folgende Leistungen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Anwender-Unterst\'FCtzung und Beratung beim Betrieb des Geb\'E4udeleitsystems \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Analyse und Unterst\'FCtzung bei Systemst\'F6rungen inkl. qualifizierter R\'FCckmeldungen f\'FCr Probleml\'F6sungen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Unterst\'FCtzung bei der Fehleranalyse in unterlagerten Systemen inkl. etwaiger Abstimmungen mit anderen Lieferanten  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Support bei Netzwerkproblemen inkl. etwaiger Abstimmungen mit der IT-Abteilung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Vorschlag und Umsetzung von vorl\'E4ufigen Probleml\'F6sungen (\u8222 ?Workarounds\u8220 ?) im Fall von kritischen St\'F6rungen oder    Problemen, die programmatisch nicht gel\'F6st werden k\'F6nnen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Durchf\'FChrung kleinerer System- und Funktionserweiterungen per Ferneiwahl\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Basierend auf Softwarepflege- und Update-Vereinbarung - Anhang D.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 5 Std pauschal pro Kalenderjahr, \par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 dar\'FCber hinaus Abrechnung nach Aufwand auf Basis von 135 \u8364 ? die Stunde, Abrechnung im 30 Minuten-Takt \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0120\tab\f0\b Hotline-Support-Vereinbarung 10 Std.\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Unter den System-Support fallen folgende Leistungen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Anwender-Unterst\'FCtzung und Beratung beim Betrieb des Geb\'E4udeleitsystems \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Analyse und Unterst\'FCtzung bei Systemst\'F6rungen inkl. qualifizierter R\'FCckmeldungen f\'FCr Probleml\'F6sungen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Unterst\'FCtzung bei der Fehleranalyse in unterlagerten Systemen inkl. etwaiger Abstimmungen mit anderen Lieferanten  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Support bei Netzwerkproblemen inkl. etwaiger Abstimmungen mit der IT-Abteilung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Vorschlag und Umsetzung von vorl\'E4ufigen Probleml\'F6sungen (\u8222 ?Workarounds\u8220 ?) im Fall von kritischen St\'F6rungen oder    Problemen, die programmatisch nicht gel\'F6st werden k\'F6nnen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Durchf\'FChrung kleinerer System- und Funktionserweiterungen per Ferneiwahl\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Basierend auf Softwarepflege- und Update-Vereinbarung - Anhang D.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 10 Std pauschal pro Kalenderjahr,\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 dar\'FCber hinaus Abrechnung nach Aufwand auf Basis von 125 \u8364 ? die Stunde, Abrechnung im 30 Minuten-Takt\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0130\tab\f0\b Hotline-Support-Vereinbarung 20 Std.\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Unter den System-Support fallen folgende Leistungen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Anwender-Unterst\'FCtzung und Beratung beim Betrieb des Geb\'E4udeleitsystems \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Analyse und Unterst\'FCtzung bei Systemst\'F6rungen inkl. qualifizierter R\'FCckmeldungen f\'FCr Probleml\'F6sungen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Unterst\'FCtzung bei der Fehleranalyse in unterlagerten Systemen inkl. etwaiger Abstimmungen mit anderen Lieferanten  \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Support bei Netzwerkproblemen inkl. etwaiger Abstimmungen mit der IT-Abteilung\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Vorschlag und Umsetzung von vorl\'E4ufigen Probleml\'F6sungen (\u8222 ?Workarounds\u8220 ?) im Fall von kritischen St\'F6rungen oder    Problemen, die programmatisch nicht gel\'F6st werden k\'F6nnen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 - Durchf\'FChrung kleinerer System- und Funktionserweiterungen per Ferneiwahl\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Basierend auf Softwarepflege- und Update-Vereinbarung - Anhang D.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 20 Std pauschal pro Kalenderjahr,\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 dar\'FCber hinaus Abrechnung nach Aufwand auf Basis von 115 \u8364 ? die Stunde, Abrechnung im 15 Minuten-Takt \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.14.0140\tab\f0\b Systemwartung vor Ort\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Eine entsprechende Softwarepflege- und Update-Vereinbarung vorausgesetzt erbringt der Auftragnehmer im Rahmen der \u8222 ?Systemwartung vor Ort\u8220 ? folgende Leistungen in Abstimmung mit den Ansprechpartnern des Aufraggebers: \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - Pr\'FCfung des Release-Standes, Einspielen von Service-Releases und Bug-Fixes \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - Einspielen von Sicherheitsupdates \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - \'DCberpr\'FCfung und Pflege der Datenbanken des ICONAG-Systems\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - \'DCberpr\'FCfung der Kommunikation mit unterlagerten Systemen\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - Funktionspr\'FCfung von systemeigenen Peripherieger\'E4ten wie Drucker, Modem o.\'E4.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - Durchf\'FChrung von Updates des Betriebssystems \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - Durchf\'FChrung von Versionsupdates des ICONAG-Systems sowie von Datenservern\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - Durchf\'FChrung System- und Funktionserweiterungen \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 - Einweisung und Schulung von Mitarbeitern\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Die Systemwartung umfasst:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 1x Tag vor Ort bei max. 8 Stunden inklusive Anfahrt und \'DCbernachtung\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Basierend auf Softwarepflege- und Update-Vereinbarung - Anhang E.\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Pauschal pro Kalenderjahr\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.14\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Wartung und Softwarepflege\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.15\tab\f0\b Testaufbau BACnet-Kommunikation BACnet-MBE und BACnet-AS\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.15.0010\tab\f0\b Testaufbau BACnet-MBE\line\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Tagessatz f\'FCr einen Testaufbau zur Pr\'FCfung der Kommunikation und Integrationsf\'E4higkeit der unterlagerten BACnet-Automationsstationen vor Ort in Terminabsprache mit dem Fachplaner und dem ausf\'FChrenden Unternehmen auf Automationsebene. Kosten f\'FCr \'DCbernachtung und Anfahrt sind in dieser Position mit zu ber\'FCcksichtigen.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs22\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.15.0020\tab\f0\b Integrationstest\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Vor der Einrichtung und Inbetriebnahme des Gesamtsystems ist ein Integrationstest mit den auf die Management- und Bedienstation zu integrierenden Automationsstationen und Systemen durchzuf\'FChren, um die Kommunikationsf\'E4higkeit zu testen. Hierzu ist vom jeweiligen Auftragnehmer exemplarisch eine Automationsstation je Fabrikat und Typ einzurichten und in Betrieb zu nehmen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der Integrationstest wird auf die je System vereinbarte Kommunikationsschnittstelle angepasst.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu pr\'FCfen sind:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls19\ilvl2{\listtext\fs20 1.\tab}\pnstart1\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Vollst\'E4ndige Schnittstellenbeschreibung und Datenpunkttabelle je AS\par
\pard\ls19\ilvl2{\listtext\fs20 2.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Durchg\'E4ngige und korrekte Verwendung Kennzeichnungssystem\par
\pard\ls19\ilvl2{\listtext\fs20 3.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Korrekte Daten\'FCbernahme ins MBE-System\par
\pard\ls19\ilvl2{\listtext\fs20 4.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Ausf\'FChrung von Alarm- und Meldungslogiken, Zeitschaltfunktionen, Anlagen- und Betriebsartenschaltern, etc. \par
\pard\ls19\ilvl2{\listtext\fs20 5.\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Kommunikation (lesend, schreibend)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der Integrationstest erfolgt in Zusammenarbeit mit dem Planer/Bauherr und dem auf Automationsebene ausf\'FChrenden Unternehmen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Integrationstest f\'FCr 2 Tage, mit je bis zu 8 Std. psch. vor Ort, inkl. Anfahrt und \'DCbernachtung eines ICONAG Systemtechnikers.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.15\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Testaufbau BACnet-Kommunikation BACnet-MBE und BACnet-AS\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.16\tab\f0\b Schulung\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.16.0010\tab\f0\b B-CON Start-Up-Schulung\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Die 2-T\'E4gige Start-Up-Schulung in unserem Trainings-Center\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Folgende Themen werden geschult:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Installation der Software (Editor)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Grundlagen der Systemarchitektur (Bedienkonzepte, Lizenzthemen, Systemvorr.)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Anlegen eines neuen B-CON Projektes\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Einrichtung und Konfiguration eines Kommunikation\u8216 ?s Treibers (OPC/KNX, BACnet, ModBus).\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Importieren und Konfiguration (Eigenschaften) der Datenpunkte in B-CON\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Kennenlernen der Objekt Editor Umgebung\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Einrichten der Managementfunktionen (Alarmliste, Berechtigungsvergabe, Trends, Meldungsversand, Berechtigungsvergabe, Zeitschaltuhr)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Einrichten des Webportals unter Ber\'FCcksichtigung der IT-Systemanforderungen (Webserver)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Erstellen einer einfachen Webseite unter Verwendung der Controltypen Numerisch, Enum, String und Bool\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Erstellen einer einfachen Webseite unter Verwendung der Bacnettypen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Erstellen von einfachen Seiten Navigation und Dialogen (lokal und Web).\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Einfache Gestaltungsm\'F6glichkeiten (Farb\'E4nderung, Form und Gr\'F6\'DFe, Ebenen)\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Ausblick auf weitere Schulungen\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Preis je Schulungsteilnehmer.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Hersteller: ICONAG\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Typ: B-CON Start-Up-Schulung\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.16.0020\tab\f0\b B-CON Individualschulung\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Das Training richtet sich an alle Systempartner und B-CON Produktverwender, die mit der B-CON Creative Studio Projekte realisieren wollen. Die Inhalte des eint\'E4gigen Trainings werden vor Durchf\'FChrung gemeinsam festgelegt und individuell erarbeitet. Die Individualschulung ist auf max. 2 Teilnehmer begrenzt und findet wahlweise im ICONAG Trainings-Center oder bei Ihnen vor Ort statt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Hersteller: ICONAG\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Typ: B-CON Individualschulung\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.16.0030\tab\f0\b B-CON Bedienereinweisung und Schulung (via Online-Meeting)\par
\pard\plain\s0\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Tagessatz f\'FCr die Einweisung des Anlagenbedieners via Ferneinwahl/Online-Meetingl in Terminabsprache mit dem Bediener.\par
\pard\plain\li1701\ri1701\tx1701\wpparid0\keepn\keep\plain\fs20\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Bedienereinweisung umfasst:\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Vermittlung des grundlegenden Aufbaus des B-CON Browser-Portals\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Navigation in Anlagenbildern\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bedien- und Anzeigefunktionen\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Alarm- und Ereignismanagement\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Trendmanagement\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zeitplanmanagement\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Energiemanagement\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Objektliste\par
\pard\ls71\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 App-Center\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.16.0040\tab\f0\b B-CON Bedienereinweisung und Schulung (vor Ort)\par
\pard\plain\s0\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Tagessatz f\'FCr die Einweisung des Anlagenbedieners vor Ort in\par
\pard\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20 Terminabsprache mit dem Bediener.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Bedienereinweisung umfasst:\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Vermittlung des grundlegenden Aufbaus des B-CON Browser-Portals\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Navigation in Anlagenbildern\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Bedien- und Anzeigefunktionen\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Alarm- und Ereignismanagement\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Trendmanagement\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zeitplanmanagement\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Energiemanagement\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Objektliste\par
\pard\ls72\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 App-Center\par
\pard\plain\li1701\ri1701\tx1701\wpparflg64\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx1701\wpparflg64\keepn\keep\plain\fs20 Kosten f\'FCr \'DCbernachtung und Anfahrt sind in dieser Position mit zu ber\'FCcksichtigen.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.16\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Schulung\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 02.17\tab\f0\b Automationsebene\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 02.17.0010\tab\f0\b WAGO BACnet-Konfiguration erstellen (Device)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Dienstleistung f\'FCr die BACnet-Konfiguration je Ger\'E4t:\par
\ls73\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Vornehmen der Controller-Netzwerkonfiguration \par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Einlesen der Controller- und Klemmenkonfiguration\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Konfiguration aller erforderlichen BACnet-Eigenschaften(Properties) je Device gem\'E4\'DF Kundenvorgabe, wie:\par
\ls74\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Device_Name (nur Device_Object)\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Device_ID (nur Device_Object)\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Description (nur Device_Object)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hinweis:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Seitens des Auftraggebers sind vor der Leistungserbringung die vorgenannten BACnet-Eigenschaften und -Vorgaben an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Einspielen und R\'FCcksichern der BACnet-Konfiguration.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs15\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Pauschal je BACnet-Ger\'E4t.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 02.17.0020\tab\f0\b WAGO BACnet-Objekt konfigurieren (Analog-, Bin\'E4r, Multistate-, NC-Objekte)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Dienstleistung f\'FCr die BACnet-Konfiguration je BACnet-Objekt der Objekttypen Analog-, Bin\'E4r, Multistate- oder NotificationClass-Objekte.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Konfiguration aller erforderlichen BACnet-Eigenschaften(Properties) je Objekt gem\'E4\'DF Kundenvorgabe, wie:\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Object_Name\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Description\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Device_Type (nur AV/AO/AI)\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Units (nur AV/AO/AI)\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 COV_Increment (nur AV/AO/AI)\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Polarity (nur BV/BO/BI)\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Alarm_Value (nur BV/BO/BI/MV/MO/MI)\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Limits (nur AV/AO/AI)\par
\pard\ls75\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 NotificationClass\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hinweis:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Seitens des Auftraggebers sind vor der Leistungserbringung die vorgenannten BACnet-Eigenschaften und -Vorgaben an ICONAG zu \'FCbergeben.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Einspielen und R\'FCcksichern der BACnet-Konfiguration.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs15\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Pauschal je BACnet-Objekt.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02.17\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Automationsebene\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 02\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Dienstleistung\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 03\tab\f0\b Beratung / Planungsunterst\'FCtzung\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 03.01\tab\f0\b Standardisierung 2024\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Sie planen Ihre verteilten Liegenschaften hinsichtlich der Anlagentechnik sowie der Energieverbr\'E4uche zuk\'FCnftig \'FCber ein zentrales Managementsystem \'FCberwachen und bedienen zu k\'F6nnen. Es soll m\'F6glich sein, auf Automationsebene Systeme beliebiger Hersteller einsetzen zu k\'F6nnen. Ebenso soll die Installation durch verschiedene Dienstleister erfolgen k\'F6nnen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Hierf\'FCr haben sich Vorgaben f\'FCr \par
\ls20\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 ein projektweites, einheitliches \b Datenpunkt-Kennzeichnungssystem\b0  (Benutzeradressierungssystem nach VDI 3814)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 in Verbindung mit BACnet als Kommunikationsprotokoll und\par
\ls20\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 einem \b BACnet-Lastenheft\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 als entscheidende Erfolgsfaktoren f\'FCr effiziente und reibungslose Planungen und Realisierungen von Projekten in der Geb\'E4udeautomation etabliert.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die ICONAG hat hierzu in den vergangenen Jahren auf Basis der Empfehlungen von VDI und AMEV umfassende Vorgaben erarbeitet, die bereits erfolgreich von verschiedenen kommunalen sowie privatwirtschaftlichen Geb\'E4udebetreibern f\'FCr die effiziente Errichtung von Geb\'E4udeautomationssystemen genutzt werden.\par
\pard\plain\li1701\ri1701\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.01.0010\tab\f0\b ICONAG Datenpunkt-Kennzeichnungssystem (Benutzeradressierungssystem)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Durch die Vorgabe und Anwendung eines projektweit einheitlichen Benutzeradressierungssystems schaffen Sie die eindeutige Identifizierbarkeit von Anlagen, Aggregaten, Betriebsmitteln und Geb\'E4udeautomations-Funktionen \'FCber Ihre verteilten Liegenschaften, Geb\'E4ude sowie unterschiedliche Herstellersysteme hinweg.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die ICONAG hat in den vergangenen Jahren f\'FCr viele kommunale und privatwirtschaftliche Geb\'E4udebetreiber Kennzeichnungssysteme in Anlehnung an die Vorgaben der VDI 3814 erstellt die bereits erfolgreich im Einsatz erprobt sind.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Daraus sind eine strukturierte Dokumentation und standardisierte Vorgaben f\'FCr die erforderlichen Kennzeichnungsbl\'F6cke und -ebenen entstanden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr die Kennzeichnungsbl\'F6cke der Anlagen-, Baugruppen-, Aggregate-, Betriebsmittel- sowie Funktionskennzeichnungen k\'F6nnen wahlweise die bew\'E4hrten Vorlagen der ICONAG oder das bereits eingearbeitete, vielversprechende BACtwin-BAS-System des Arbeitskreises Maschinen- und Elektrotechnik staatlicher und kommunaler Verwaltungen (AMEV) angewendet werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Neben der Definition des Kennzeichnungssystem wird durch die Vorgaben der ICONAG ebenfalls die Strukturierung der zugeh\'F6rigen Klartextbezeichnung festgelegt.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Durch den Kauf erwerben Sie das Recht, die Dokumentationen (im Microsoft EXCEL- und WORD-Dateiformat) des ICONAG Datenpunkt-Kennzeichnungssystems in seiner zum Zeitpunkt des Kaufs befindlichen Fassung mit den gemeinsam erarbeiteten projektspezifischen Anpassungen uneingeschr\'E4nkt zu nutzen.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Strukturierung der Kennzeichnungsbl\'F6cke f\'FCr Verortung und Automatisierungsschwerpunkte wird gemeinsam erarbeitet und zus\'E4tzlich zur Pauschale nach Aufwand abgerechnet.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.01.0020\tab\f0\b ICONAG BACnet-Standard\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 In Ihren Projekten soll die zu installierende Automatisierungstechnik einheitlich \'FCber das weltweit nach DIN/EN/ISO 16484-5 standardisierte BACnet-Protokoll auf eine zentrale Management- und Bedieneinrichtung (MBE) aufgeschaltet werden. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Als Vorteile hieraus ergeben sich f\'FCr Sie z. B. die hersteller- und fabrikats\'FCbergreifende Erfassung von Verbauchsdaten, das zentrale Verwalten und Bearbeiten von Alarmen und Ereignissen sowie das zentrale \'DCberwachen und Verwalten von Zeitschaltprogrammen in allen Liegenschaften.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Da durch das BACnet-Protokoll grunds\'E4tzlich Interoperabilit\'E4t zwischen Ger\'E4ten verschiedener Hersteller gew\'E4hrleistet ist, ist es m\'F6glich BACnet-Ger\'E4te verschiedener Hersteller und Dienstleister in einem solchen Netzwerk zu integrieren. Im Sinne der durch den Arbeitskreis Maschinen- und Elektrotechnik staatlicher und kommunaler Verwaltungen (AMEV) f\'FCr die Geb\'E4udeautomation mit BACnet formulierten Empfehlungen, sind hierf\'FCr weitere Vorgaben zu machen. U.a. sind einheitliche Vorgaben f\'FCr die Verwendung der verschiedenen BACnet-Dienste und -Objekte f\'FCr eine strukturierte und m\'F6glichst reibungslose Zusammenarbeit von Fachplaner, Geb\'E4udeautomations-Hersteller und -Installationsdienstleister notwendig.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die ICONAG hat hierzu in den vergangenen Jahren umfassende BACnet-Vorgaben erarbeitet, die bereits erfolgreich von verschiedenen kommunalen sowie privatwirtschaftlichen Geb\'E4udebetreibern f\'FCr die effiziente Errichtung und den Betrieb von BACnet-Geb\'E4udeautomationssystemen in Geb\'E4udeportfolios genutzt werden.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Der ICONAG BACnet-Standard wird regelm\'E4\'DFig an relevante \'C4nderungen in neu erscheinenden Revisionen des BACnet-Protokolls angepasst.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Planen Sie den AMEV BACtwin in Ihrem Unternehmen einzuf\'FChren, so bestehen bereits ICONAG-Vorlagen f\'FCr die Einarbeitung der BACtwin-Betreibervorgaben. In diesem Zuge wird ebenfalls der ortsbezogenen Teil des BACtwin-Benutzeradressierungssystems mit Ihnen erarbeitet. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Grunds\'E4tzlich gliedern sich die Vorgaben in die folgenden f\'FCnf Themenschwerpunkte:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\tblstart1{\trowd\trleft1701\trrh1343\trftsWidth3\trwWidth9062\clftsWidth3\clwWidth1275\clvertalt\cellx2976\clftsWidth3\clwWidth2415\clvertalt\cellx5391\clftsWidth3\clwWidth5381\clvertalt\cellx10772\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 1\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 BACnet-Standardisierung\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\pard\intbl\plain\wpparflg32\keepn\keep\plain\fs20 Betreiberanforderungen und Vorgaben, BACnet Device und Objekt Identifizierung.\par
\pard\intbl\wpparflg32\keepn\keep\plain\fs20 Ableitung der Anforderungen an die BACnet-Projektierung der Automationseinrichtungen f\'FCr anstehende Neubauten oder Ersatzma\'DFnahmen.
\cell\row}{\trowd\trleft1701\trrh1343\trftsWidth3\trwWidth9062\clftsWidth3\clwWidth1275\clvertalt\cellx2976\clftsWidth3\clwWidth2415\clvertalt\cellx5391\clftsWidth3\clwWidth5381\clvertalt\cellx10772\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 2\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 BACnet-Standardisierung\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 Erarbeitung der Vorgaben f\'FCr die Verwendung von BACnet Diensten und Interoperabilit\'E4tsbereiche\cell\row}{\trowd\trleft1701\trrh1343\trftsWidth3\trwWidth9062\clftsWidth3\clwWidth1275\clvertalt\cellx2976\clftsWidth3\clwWidth2415\clvertalt\cellx5391\clftsWidth3\clwWidth5381\clvertalt\cellx10772\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 3\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 BACnet-Standardisierung\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 Erarbeitung der Vorgaben f\'FCr die Verwendung von BACnet Objekten und deren Properties\cell\row}{\trowd\trleft1701\trrh1343\trftsWidth3\trwWidth9062\clftsWidth3\clwWidth1275\clvertalt\cellx2976\clftsWidth3\clwWidth2415\clvertalt\cellx5391\clftsWidth3\clwWidth5381\clvertalt\cellx10772\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 4\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 BACnet-Standardisierung\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 Erarbeitung bzw. Anpassung der Vorgaben aus g\'E4ngigen Regelwerken f\'FCr: Datenaustausch, erweiterte Objekteigenschaften und Netzwerk\cell\row}{\trowd\trleft1701\trrh1343\trftsWidth3\trwWidth9062\clftsWidth3\clwWidth1275\clvertalt\cellx2976\clftsWidth3\clwWidth2415\clvertalt\cellx5391\clftsWidth3\clwWidth5381\clvertalt\cellx10772\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 5\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 (Optional)\cell\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\wpparflg32\keepn\keep\plain\fs20 Integrationstest: Einbindung einer, nach den erarbeiteten Vorgaben, programmierten Automationsstation auf eine vorhandene MBE zur Pr\'FCfung auf praxistaugliche Anwendung. (vor Ort)\cell\row}\tblend1\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Durch den Kauf erwerben Sie das Recht den ICONAG BACnet-Standard in seiner zum Zeitpunkt des Kaufs befindlichen Fassung mit den gemeinsam erarbeiteten projektspezifischen Anpassungen uneingeschr\'E4nkt zu nutzen.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.01.0030\tab\f0\b Anpassung der ICONAG Standards nach Stundensatz\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 In der Regel ist es notwendig einzelne Festlegungen des ICONAG Kennzeichnungssystems und des ICONAG BACnet-Standards an bereits vorhandene Standardisierungen sowie projektspezifische Gegebenheiten anzupassen. Hierzu z\'E4hlen insbesondere:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\ls21\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Anpassung der Verortungsbl\'F6cke im Kennzeichnungssystem an die Geb\'E4ude- und/oder Liegenschaftsstruktur, sowie evtl. vorhandene Bezeichnungen \par
\pard\ls21\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 BACnet Ger\'E4te-ID-Strukturierung (Device-IDs)\par
\pard\ls21\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 BACnet Meldungsklassen Strukturierung (Notification-Classes)\par
\pard\ls21\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anforderungen an BACnet Trendlog-Funktionalit\'E4ten (Trendlogs)\par
\pard\ls21\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anwendung von BACnet Zeitplan-Funktionen (Schedule)\par
\pard\ls21\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Anforderungen an kundenspezifische IT- und Netzwerkgegebenheiten\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Die f\'FCr die Anpassungen erforderlichen Beratungsleistungen werden dabei in der Regel via Online-Meetings mit Ihnen abgestimmt und per Fernarbeit erbracht. Die erbrachten Leistungen werden auf Stundenbasis nach Aufwand abgerechnet. Es gelten dabei die vereinbarten ICONAG-Stundens\'E4tze f\'FCr Beratungsleistungen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Beratungsleistungen werden von Ingenieuren oder von auf dem Fachgebiet der Geb\'E4udeautomation besonders qualifizierten Fachkr\'E4ften erbracht. Die Dokumentation erfolgt in Form von Word-, Powerpoint und Excel-Dateien, die als Grundlage f\'FCr Ihre etwaige weitere Standardisierungsarbeit dienen k\'F6nnen.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.01.0040\tab\f0\b Beratungsleistungen vor Ort\par
\pard\plain\s0\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Beratungsleistungen vor Ort werden auf Basis von ICONAG-Tages\'E4tzen f\'FCr Beratungsleistungen, zzgl. Reise- und \'DCbernachtungskosten sowie Spesen nach Aufwand abgerechnet.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.01.0050\tab\f0\b Vorbereitung eines Integrationstests\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Um erarbeitete Vorgaben f\'FCr Kennzeichnungssystem und BACnet-Standardisierung auf praxistaugliche Anwendung zu \'FCberpr\'FCfen ist ein Integrationstest durchzuf\'FChren.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Hierzu wird von ICONAG eine BACnet-Automationsstation gem\'E4\'DF den mit Ihnen erarbeiteten Vorgaben programmiert. Kennzeichnungssystem und BACnet-Vorgaben werden dabei auf zwei g\'E4ngige Anlagentypen (Raumlufttechnische Anlage und Heizkreisverteiler) angewendet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Automationsstation wird im Rahmen des Integrationstests auf die vorhandene BACnet-Management- und Bedieneinrichtung integriert (bei einer Fremd-MBE sind die erforderlichen Dienstleistungen auf Seiten der MBE durch den AG zu erbringen). Der erforderliche Vor-Ort-Einsatz des ICONAG Beraters wird separat nach Aufwand abgerechnet.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Im Rahmen des Integrationstest werden u.a. folgende Pr\'FCfungen durchgef\'FChrt:\par
\pard\ls22\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Objekte anhand des Kennzeichnungssystems im MBE-System durch den Nutzer identifizierbar\par
\pard\ls22\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Verortung von Objekten gem\'E4\'DF der Kennzeichnungssystem-Strukturierung im MBE-System sinnvoll m\'F6glich (z.B. Darstellung in einer Baumstruktur)\par
\pard\ls22\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Strukturierung der Klartexte sinnvoll und in allen Anzeigefeldern des MBE-Systems auch bei maximaler L\'E4nge lesbar\par
\pard\ls22\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Geforderte BACnet-Objekte durch das MBE-System integrierbar\par
\pard\ls22\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Geforderte BACnet-Objekte in allen erforderlichen Modulen und Anlagenbildern darstell- und bedienbar\par
\pard\ls22\ilvl0{\listtext\fs20 -\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Geforderte BACnet-Dienste und -Funktionen k\'F6nnen durch das MBE-System abgebildet werden (u.a. BACnet-Alarming, -Trending und -Scheduling)\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Die f\'FCr den Integrationstest erforderlichen IT- und netzwerktechnischen Voraussetzungen sind durch den AG zu erbringen. \par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.01.0060\tab\f0\b Beratungsleistungen nach Stundensatz (Im ICONAG-B\'FCro oder via Online-Meeting)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20 Stundensatz zur Erbringung von Beratungsleistungen im Kundenauftrag, durchgef\'FChrt im ICONAG-B\'FCro oder via Online-Meetings. Die erbrachten Leistungen werden auf Stundenbasis nach Aufwand abgerechnet. Es gelten dabei die vereinbarten ICONAG-Stundens\'E4tze f\'FCr Beratungsleistungen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Beratungsleistungen werden von Ingenieuren oder von auf dem Fachgebiet der Geb\'E4udeautomation besonders qualifizierten Fachkr\'E4ften erbracht. Dokumentationen erfolgen in Form von Word-, Powerpoint und Excel-Dateien, die als Grundlage f\'FCr Ihre etwaige weitere Standardisierungs- und Planungsarbeit dienen k\'F6nnen.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.01.0070\tab\f0\b Reisekostenpauschale ICONAG-Berater\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Idar-Oberstein =>\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Pauschale deckt folgende Kosten ab:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1. An- und Abreisezeit f\'FCr die reisende Person\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 2. Fahrzeug-, Bahn- oder Flugkosten f\'FCr die An- und Abreise\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.01.0080\tab\f0\b\'DCbernachtungen inkl. Spesen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Deckt die \'DCbernachtungskosten inkl. Spesen eines ICONAG-Systemtechnikers ab.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je \'DCbernachtung.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 03.01\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Standardisierung 2024\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 03.02\tab\f0\b Ausf\'FChrungsplanung BACnet-Konfiguration\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 03.02.0010\tab\f0\b Ausf\'FChrungsplanung der BACnet-Konfiguration\par
\pard\plain\s0\li1701\ri1701\sl201\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Ausf\'FChrungsplanung der BACnet-Konfiguration f\'FCr die BACnet Management- und Bedieneinrich\-tung (BACnet-MBE) und die BACnet-Automationsstationen (BACnet-AS): \par
\sl241\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Entwicklung der Vorgaben f\'FCr die Konfiguration der BACnet-Objekte auf Basis des Betriebskonzeptes des Geb\'E4udes sowie der DIN EN ISO 16484-5. Koordination der Vorgaben mit den Projektbeteiligten. Insbeson\-dere sind Vorgaben f\'FCr folgende MBE- bzw. BACnet-Funktionen zu treffen: \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Globale Funktionen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Raumbedienung\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Anlagenbedienung\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Handbedienung f\'FCr R\'E4ume und Anlagen\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Alarmverarbeitung\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - Zeitschaltfunktionen\par
\sl201\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 - Historisierung"\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - BACnet-Objekt-Eigenschaften\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - BACnet-Alarming\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - BACnet-Trending\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 - BACnet- Scheduling\par
\pard\plain\li1701\ri1701\sa113\sl201\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 03.02\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Ausf\'FChrungsplanung BACnet-Konfiguration\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 03.03\tab\f0\b BACnet-Netzwerkanalyse\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Ausgangslage und Aufgabenstellung \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Sie betreiben ein umfangreiches BACnet-Geb\'E4udeautomationsnetzwerk, dass zuk\'FCnftig noch weiter ausgebaut werden soll. \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Es treten bereits Kommunikationsausf\'E4lle und Performanceprobleme auf. \par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Dar\'FCber hinaus gibt es keine Klarheit \'FCber die Verbindungen und Kommunikationsstrecken zwischen den verschiedenen BACnet-Netzwerkteilnehmern.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 ICONAG f\'FChrt eine umfangreiche BACnet-Analyse in Ihrem Netzwerk durch, bei der u.a. folgende Pr\'FCfungen durchgef\'FChrt werden k\'F6nnen:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\par
\ls76\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20 Ermitteln von BACnet Broadcast Management Devices (BBMDs) sowie \'DCberpr\'FCfung der eingerichteten Kommunikationsverbindungen \par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Ermittlung aller vorhandenen BACnet-Teilnehmer\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'DCberpr\'FCfung von vergebenen Device-IDs (gem\'E4\'DF Kundenstruktur)\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\'DCberpr\'FCfung von BACnet Object-Names auf Namenskonvention gem\'E4\'DF Kunden-BAS\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\'DCberpr\'FCfung von verwendeten BACnet-Revisions-St\'E4nden von BACnet-Ger\'E4ten \par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\'DCberpr\'FCfung von Uhrzeit- und Datumseinstellungen in BACnet-Ger\'E4te \par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\'DCberpr\'FCfung der H\'E4ufigkeit von versendeten \u8222 ?Who-Is"-Service Nachrichten \par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\'DCberpr\'FCfung der H\'E4ufigkeit von versendeten \u8222 ?(Utc)TimeSynchronization"-Service Nachrichten \par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\plain\fs20\'DCberpr\'FCfung von Schwellenwert-Inkrementen (COV-Increments) bei analogen Objekten \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die durchzuf\'FChrenden Pr\'FCfszenarien werden in einem vorbereitenden Meeting besprochen und festgelegt.\par
\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Im Anschluss an die BACnet-Netzwerkanalyse werden die gewonnenen Erkenntnisse seitens ICONAG in einem Ergebnisbericht aufbereitet und M\'F6glichkeiten f\'FCr Optimierungen des Aufbaus sowie der Einrichtung des BACnet-Netzwerks aufgezeigt.\par
\sa0\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b HINWEIS:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\ls77\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die nachfolgend ausgewiesenen Aufw\'E4nde beruhen auf einer Sch\'E4tzung. Je nach tats\'E4chlichen Gegebenheiten k\'F6nnen weitere Vor-Ort-Eins\'E4tze n\'F6tig werden, um eine umfassende Anlayse durchf\'FChren zu k\'F6nnen. Auch k\'F6nnen weitere Stundens\'E4tze erforderlich werden, um die gewonnen Erkenntnisse aufzubereiten und zu dokumentieren.\par
\pard\ls77\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr die Netzwerkanalyse werden spezielle ICONAG Softwaretools ben\'F6tigt, die auf einem ICONAG-Notebook vorinstalliert sind. Diese Notebook muss am Vor-Ort-Termin f\'FCr die Netzwerkanalyse in das betreffende Geb\'E4udeautomationsnetzwerk des Kunden integriert werden. Alle BACnet-Subnetze m\'FCssen erreichbar sein. Die entsprechenden Netzwerkrouten und BACnet-Portfreigaben m\'FCssen durch die Kunden-IT eingerichtet sein.\par
\pard\ls77\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Vorab sind ICONAG nach M\'F6glichkeit folgende Unterlagen zu \'FCbersenden:\par
\pard\ls77\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 eine aktuelle IP-Adressliste mit allen BACnet-Ger\'E4ten, deren Devcie-IDs, sowie dem Status der BACnet-Broadcast-Management-Device-Funktionalit\'E4t (BBMD)\par
\pard\ls77\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Netzwerktopologie\par
\pard\ls77\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keep\plain\fs20 Ggf. kann es n\'F6tig werden, sich an einen Netzwerkport einer BACnet-Automationsstation in einem Automationsschwerpunkt in das Netzwerk einzubinden. F\'FCr diesen Fall ist seitens des AG ein Mitarbeiter mit entsprechender Ortskenntnis und Zutrittsberechtigung beizustellen. \par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 03.03.01\tab\f0\b Vorbereitung\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 03.03.01.0010\tab\f0\b Online-Meeting: Besprechung Pr\'FCfszenarien, Technik und Infrastruktur (nach Stundensatz)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 In einem Online-Meeting werden die m\'F6glichen Pr\'FCfverfahren vorgestellt und basierend auf den Anforderungen des Kunden die ben\'F6tigten Pr\'FCfszenarien zusammengestellt.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Dar\'FCber hinaus werden die kundenseitigen Voraussetzungen zur Durchf\'FChrung der Analyse beprochen (IT-Infrastruktur, Netzwerkaufbau, etc.)\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.03.01.0020\tab\f0\b Zusammenstellung und Aufbereitung der Pr\'FCfszenarien\par
\pard\plain\s0\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\par
\pard\plain\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 03.03.01\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Vorbereitung\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 03.03.02\tab\f0\b BACnet-Netzwerkanalyse vor Ort\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b HINWEIS:\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\ls78\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\sa227\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Leistungen vor Ort werden von zwei ICONAG-Mitarbeitern an zwei Tagen erbracht.\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.03.02.0010\tab\f0\b Beratungsleistungen vor Ort\par
\pard\plain\s0\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparid0\keepn\keep\plain\fs20 Beratungsleistungen vor Ort werden auf Basis von ICONAG-Tages\'E4tzen f\'FCr Beratungsleistungen, zzgl. Reise- und \'DCbernachtungskosten sowie Spesen nach Aufwand abgerechnet.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.03.02.0020\tab\f0\b Reisekostenpauschale ICONAG-Berater\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Idar-Oberstein => \par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Pauschale deckt folgende Kosten ab:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 1. An- und Abreisezeit f\'FCr die reisende Person\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 2. Fahrzeug-, Bahn- oder Flugkosten f\'FCr die An- und Abreise\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 03.03.02.0030\tab\f0\b\'DCbernachtungen inkl. Spesen\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Deckt die \'DCbernachtungskosten inkl. Spesen eines ICONAG-Systemtechnikers ab.\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je \'DCbernachtung.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 03.03.02\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b BACnet-Netzwerkanalyse vor Ort\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 03.03.03\tab\f0\b Aufbereitung Ergebnisse und Ableitungen\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 03.03.03.0010\tab\f0\b Beratungsleistungen nach Stundensatz (Im ICONAG-B\'FCro oder via Online-Meeting)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20 Stundensatz zur Erbringung von Beratungsleistungen im Kundenauftrag, durchgef\'FChrt im ICONAG-B\'FCro oder via Online-Meetings. Die erbrachten Leistungen werden auf Stundenbasis nach Aufwand abgerechnet. Es gelten dabei die vereinbarten ICONAG-Stundens\'E4tze f\'FCr Beratungsleistungen. \par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\wpparflg32\plain\fs20\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Beratungsleistungen werden von Ingenieuren oder von auf dem Fachgebiet der Geb\'E4udeautomation besonders qualifizierten Fachkr\'E4ften erbracht. Dokumentationen erfolgen in Form von Word-, Powerpoint und Excel-Dateien, die als Grundlage f\'FCr Ihre etwaige weitere Standardisierungs- und Planungsarbeit dienen k\'F6nnen.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 03.03.03\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Aufbereitung Ergebnisse und Ableitungen\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 03.03.04\tab\f0\b Abschluss\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 03.03.04.0010\tab\f0\b Online-Meeting: Besprechung Ergebnisse (nach Stundensatz)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 In einem Online-Meeting werden die Ergebnisse der BACnet-Netzwerkanalyse vorgestellt und konkrete Ma\'DFnahmen und Handlungsempfehlungen besprochen.\par
\pard\plain\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 03.03.04\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Abschluss\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 03.03\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b BACnet-Netzwerkanalyse\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 03\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Beratung / Planungsunterst\'FCtzung\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 04\tab\f0\b BACnet Tools\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 04.01\tab\f0\b Software\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 04.01.0010\tab\f0\b BACnet Tools - Modul "Bedienen"\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 BACnet bietet erhebliche Vorteile hinsichtlich Ausfallsicherheit bei der Ausf\'FChrung von Zeitschaltaufgaben sowie datumsbasierten Ausnahmebehandlungen, in dem Wochenzeitschaltpl\'E4ne (BACnet Schedule Object) und Kalenderfunktionen (BACnet Calendar Object) mit standardisierten Objekten dezentral auf den Automationsstationen abgelegt und ausgef\'FChrt werden.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Vorteile der Ausfallsicherheit stehen allerdings einem erh\'F6htem Aufwand bei der Bearbeitung und Pflege von Zeitschalt- und Kalendereintr\'E4gen gegen\'FCber, da \'C4nderungen an einer Vielzahl von identischen Wochenzeitschaltprogrammen oder Kalendern einer sequenzielle Bearbeitung durch den Nutzer bedarf.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Aus diesem Grund muss das zu liefernde MBE-System ein Modul bereitstellen, das eine Massenbearbeitung von BACnet Schedule und Calendar Objekten erm\'F6glicht.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Das Modul muss es hierzu erm\'F6glichen eine beliebige Anzahl an BACnet Schedule bzw.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Calendar Objekte liegenschafts-, geb\'E4ude- sowie auch ger\'E4te- und hersteller\'FCbergreifend auszuw\'E4hlen und in eigenen Vorlagen abzuspeichern.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Eine gespeicherte Vorlage muss im Nachgang jederzeit f\'FCr Bearbeitungen ge\'F6ffnet werden k\'F6nnen.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 F\'FCr Schedule Objekte muss es anschlie\'DFend m\'F6glich sein, auf Basis eines auszuw\'E4hlenden Objektes Eintr\'E4ge im Wochenzeitschaltplan (Weekly_Schedule), dem Ausnahmeplan (Exception_Schedule) sowie in allen weiteren relevanten Eigenschaften des Objektes (wie z.B.\'A0 Priority_For_Writing, Effective_Period, Schedule_Default) zu bearbeiten.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 F\'FCr Calendar Objekte muss es m\'F6glich sein, auf Basis eines auszuw\'E4hlenden Objektes Eintr\'E4ge in der Datumsliste (Date_List) sowie weiteren relevanten Eigenschaften des Objektes zu bearbeiten.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Im weiteren Schritt m\'FCssen die gemachten \'C4nderungen auf alle Objekte der Vorlage heruntergeschrieben werden k\'F6nnen.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Abschlie\'DFend ist dem Nutzer eine Status\'FCbersicht anzuzeigen, die erfolgreiche Schreibvorg\'E4nge bzw. Fehler anzeigt, wenn bei einzelnen Objekten das Herunterschreiben nicht funktioniert hat. Zu einem Schreibvorgang muss vom Nutzer ein Kommentar hinterlegt werden k\'F6nnen, der im Systemlogbuch abgelegt wird.\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Funktionsumfang:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\ls79\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\plain\fs20 Anzeigen und Bearbeiten von einzelnen BACnet Wochenzeitschaltpl\'E4nen (schedule), dessen Ausnahmezeitplan (Exception Schedule), sowie alle weiteren Eigenschaften (properties) des Objektes => BACnet Zeitplan Editor\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\ql\vertalc\plain\fs20 Anzeigen und Bearbeiten von einzelnen BACnet Kalendern (calendar) sowie alle weiteren Eigenschaften (properties) des Objektes => BACnet Kalender Editor\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\ql\vertalc\plain\fs20 Anzeigen und Bearbeiten eines BACnet Wochenzeitschaltplans dessen Ausnahmezeitplan (exception-schedule), sowie alle weiteren Eigenschaften (properties) und anschlie\'DFendes Schreiben dieser ger\'E4te\'FCbergreifend auf eine beliebige Anzahl von Wochenzeitschaltplan-Objekten => BACnet Multi Zeitplan Editor\par
{\listtext\f6\fs20 \'B7\tab}\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\ql\vertalc\plain\fs20 Anzeigen und Bearbeiten eines BACnet Kalenders sowie dessen Eigenschaften (properties) und anschlie\'DFendes Schreiben dieser ger\'E4te\'FCbergreifend auf eine beliebige Anzahl von Wochenzeitschaltplan-Objekten => BACnet Multi Kalender Editor\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 04.01.0020\tab\f0\b BACnet Tools - Modul "Planen und Pr\'FCfen"\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das Modul "Planen und Pr\'FCfen" der ICONAG BACnet Tools erm\'F6glicht es, kundenspezifische Benutzeradressierungssysteme (BAS) anzulegen, zu pflegen und Pr\'FCfungen durchzuf\'FChren.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Je Benutzeradressierungssystem k\'F6nnen die erforderlichen BAS-Bl\'F6cke angelegt und die jeweiligen K\'FCrzel hinterlegt werden. Soll der AMEV BACtwin zur Anwendung kommen, so k\'F6nnen die BACtwin Bl\'F6cke mit allen K\'FCrzeln und Abh\'E4ngigkeiten komfortabel importiert werden. F\'FCr Planung und Ausf\'FChrung k\'F6nnen die Benutzeradressierungssysteme in eine detaillierte Excel-Mappe sowie zugeh\'F6riger Dokumentation exportiert werden. BACnet-Objektnamen und BACnet-Descriptions von EDE- Dateien oder im Netzwerk erreichbaren BACnet-Ger\'E4ten k\'F6nnen anschlie\'DFend im Baustein "BACtwin Pr\'FCfungen" gegen die angelegten Benutzeradressierungssysteme gepr\'FCft werden.\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Funktionsumfang:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Anlegen und pflegen von kundenspezifischen Benutzeradressierungssystemen\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Optionale Zuordnung von Benutzeradressierungssystemen zu Kunden/Organisationen\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Strukturierung der Benutzeradressierungssysteme mit umfangreich definierbaren Kennzeichnungsbl\'F6cken\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Komfortabler Import des AMEV BACtwin-BAS samt aller K\'FCrzel und Abh\'E4ngigkeiten\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Importfunktion f\'FCr eigene K\'FCrzel-Listen\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Integrierter Editor zur Erstellung der Dokumentation\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Exportfunktion f\'FCr Dokumentation und Benutzeradressierungssystem\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Pr\'FCfung von EDE-Dateien oder im Netzwerk erreichbaren BACnet-Ger\'E4ten\par
\pard\ls80\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Export von Pr\'FCfberichten\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 04.01.0030\tab\f0\b BACnet Tools - Modul "Analysieren"\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das Modul "Analysieren" muss in Form von Teilmodulen die Ermittlung und das Auslesen von BACnet Broadcast Management Devices (BBMD), die Pr\'FCfung von betreiberspezifisch festzulegenden Parametrierungen von BACnet Properties sowie das Aufzeichnen und Auswerten der BACnet Netzwerkkommunikation erm\'F6glichen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Im Teilmodul "Ermitteln und Auslesen von BACnet Broadcast Management Devices (BBMD)" muss es m\'F6glich sein eine beliebige Anzahl von IP-Bereichen anzugeben, die im Anschluss auf BACnet-Ger\'E4te untersucht werden, deren BBMD-Funktionalit\'E4t aktiviert ist.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Von jedem gefundenen BBMD muss zus\'E4tzlich die Broadcast-Distribution- (BDT) sowie die Foreign-Device-Table (FDT) ausgelesen werden.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Ergebnisse m\'FCssen dem Nutzer tabellarisch aufbereitet dargestellt werden. Hierbei m\'FCssen alle gefundenen Ger\'E4te nach BBMDs gefiltert werden k\'F6nnen. Je BBMD m\'FCssen die BDT sowie die FDT angezeigt werden k\'F6nnen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu Dokumentationszwecken m\'FCssen die Ergebnisse mit allen BDT- und FDT-Eintr\'E4gen je BBMD in eine Excel-Mappe exportiert werden k\'F6nnen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Im Teilmodul "Pr\'FCfung von Parametrierungen von BACnet Properties" muss es m\'F6glich sein eine beliebige Anzahl an Pr\'FCfszenarien anzulegen. In jedem Pr\'FCfszenarium k\'F6nnen betreiberspezifische Pr\'FCffunktionen hinterlegt werden.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Dabei m\'FCssen einfache sowie komplexe Funktionen mittels "Wenn, dann"-Anweisungen definiert werden k\'F6nnen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 F\'FCr die Pr\'FCffunktionen muss mindestens auf alle Properties, die von der BACnet Revision 1.19 unterst\'FCtzt werden, zugegriffen werden k\'F6nnen. Ein Beispiel f\'FCr eine komplexe Funktion stellt die \'DCberpr\'FCfung der COV_Increment-Property\'A0 auf Werte gr\'F6\'DFer 0 dar, wenn die Units-Property dem Wert der Einheit Grad Celsius entspricht.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das Teilmodul muss es anschlie\'DFend erm\'F6glichen alle BACnet Ger\'E4te im Netzwerk aufzulisten und Pr\'FCfung auf eine beliebige Anzahl an auszuw\'E4hlenden Ger\'E4ten anzusto\'DFen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Pr\'FCfergebnisse m\'FCssen dem Nutzer in tabellarischer und gut verst\'E4ndlicher Form dargestellt werden.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu Dokumentationszwecken m\'FCssen die Ergebnisse in eine Excel-Mappe exportiert werden k\'F6nnen.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Das Teilmodul "Aufzeichnen und Auswerten der BACnet Netzwerkkommunikation" muss es erm\'F6glichen f\'FCr einen vom Nutzer definierbaren Zeitraum die BACnet-Kommunikation im Netzwerk aufzuzeichnen und anschlie\'DFend in tabellarischer Form auszugeben. Die Ergebnisse m\'FCssen u.a. nach BACnet-Service, IP-Adresse und Device-ID gefiltert und sortiert werden k\'F6nnen.\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Zu Dokumentationszwecken m\'FCssen die Ergebnisse in eine Excel-Mappe exportiert werden k\'F6nnen.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 04.01\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Software\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 04.02\tab\f0\b Dienstleistungen\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 04.02.0010\tab\f0\b BACnet Tools - Online-Schulung Modul "Bedienen"\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Online-Schulung zum effektiven Einsatz der Funktionen des Moduls "Bedienen".\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Schulungsinhalte:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\ls81\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\plain\fs20 Grundlegende Systemeinstellungen\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\ql\vertalc\plain\fs20 Benutzerverwaltung: Benutzerprofile und Benutzer anlegen und verwalten\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\ql\vertalc\plain\fs20 Auswerten von Systemlog-Eintr\'E4gen\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\ql\vertalc\plain\fs20 Bearbeiten von BACnet Schedule-Objekten mit den Bausteinen Zeitplan- und Multi-Zeitplan-Editor\par
{\listtext\f6\fs20 \'B7\tab}\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\ql\vertalc\plain\fs20 Bearbeiten von BACnet Calendar-Objekten mit den Bausteinen Kalender- und Multi-Kalender-Editor\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Die Schulung findet Online statt und umfasst bis zu 2 Stunden.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 04.02.0020\tab\f0\b BACnet Tools - Online-Schulung Modul "Planen und Pr\'FCfen"\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Online-Schulung zum effektiven Einsatz der Funktionen des Moduls "Planen und Pr\'FCfen".\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Schulungsinhalte:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Grundlegende Systemeinstellungen\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Benutzerverwaltung: Benutzerprofile und Benutzer anlegen und verwalten\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Auswerten von Systemlog-Eintr\'E4gen\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Organisationsverwaltung: Anlegen und bearbeiten von Organisationen\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 BACtwin-Editor:\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Erstellen von Benutzeradressierungssystemen\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Anlegen und Arbeiten mit Kennzeichnungsbl\'F6cken\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Import des BACtwin-BAS\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Import von eignen K\'FCrzellisten\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Arbeiten mit Abh\'E4ngigkeiten\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Bearbeiten von BAS-Dokumentationen\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Konfigurieren der Exportfunktion\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 BACtwin-Pr\'FCfungen\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Import von BACnet EDE-Dateien und Ausf\'FChrung von Pr\'FCfungen gegen erstellte Benutzeradressierungssysteme\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Browsen von BACnet-Ger\'E4ten im Netzwerk und Ausf\'FChrung von Pr\'FCfungen gegen erstellte Benutzeradressierungssysteme\par
\pard\ls82\ilvl0{\listtext\f6\fs20 \'B7\tab}\li2781\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\keepn\keep\plain\fs20 Export von Pr\'FCfberichten\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Die Schulung findet Online statt und umfasst bis zu 4 Stunden.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 psch\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 04.02.0030\tab\f0\b BACnet Tools - Installations- und Einrichtungs-Support nach Stundensatz via Ferneinwahl\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Stundensatz eines ICONAG Systemtechnikers zur Unterst\'FCtzung bei der Installation und Einrichtung der ICONAG BACnet Tools via Ferneinwahl.\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\'A0\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Eine M\'F6glichkeit zur Ferneinwahl auf das Zielsystem ist seitens des AG zur Verf\'FCgung zu stellen.\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 St\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 04.02\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Dienstleistungen\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\page\pard\plain\plain\s8\li1701\fi-1701\ri1701\sb0\sa227\ql\vertalt\f0\fs20\b0 04.03\tab\f0\b Support und Softwarepflege\par
\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\f0\fs20\b0 04.03.0010\tab\f0\b BACnet Tools - Softwarepflege- und Updatevereinbarung (Laufzeit 1 Jahr)\par
\pard\plain\s0\ls83\ilvl0{\listtext\fs20 1)\tab}\li2421\fi-360\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\plain\fs20 Pr\'E4ambel: Der Lizenznehmer der ICONAG-Softwareprodukte sowie die ICONAG m\'F6chten eine m\'F6glichst lange Nutzungsdauer des durch den Lizenznehmer erworbenen ICONAG Software-Systems sicherstellen. Darum haben beide Parteien ein Interesse daran, dass die lizenzierten Softwareprodukte weiterentwickelt werden und vereinbaren diese Softwarepflege- und Update-Vereinbarung (im Folgenden SPUV). Mit dieser SPUV unterst\'FCtzt der Lizenznehmer die Weiterentwicklung der Software und erwirbt gleichzeitig das Recht, die jeweils neueste Version der eingesetzten ICONAG-Software anzufordern. Die SPUV wird mit dem Erst-Erwerb der ICONAG-Lizenzen abgeschlossen. Ein sp\'E4terer Abschluss f\'FChrt zu einer Nachberechnung (siehe Punkt 4).\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\plain\fs20\par
\ls83\ilvl0{\listtext\fs20 2)\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\ql\vertalc\plain\fs20 Updates und Leistungen: ICONAG passt die ICONAG Produkte entsprechend dem technischen Fortschritt, den W\'FCnschen der Anwender sowie der Erfahrung der ICONAG an. Dies f\'FChrt zu Versionsupdates, Service-Releases und Bug-Fixes an den durch den Lizenznehmer lizenzierten ICONAG-Softwareprodukten. Diese stellt ICONAG dem Lizenznehmer kostenlos per Datentr\'E4ger (z. B. USB-Stick, DVD) oder Download zur Verf\'FCgung. Eine Installation ist im Rahmen dieser Vereinbarung nicht geschuldet (enth\'E4lt keine Projektierungsleistung seitens ICONAG). ICONAG macht dabei keine Zusagen bez\'FCglich der Zyklen von Versionsupdates und Servicereleases. Sobald ein Update ausgeliefert ist, tritt es hinsichtlich der Nutzungsrechte an die Stelle der alten Programmversion.\par
\pard\li1989\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\ls83\ilvl0{\listtext\fs20 3)\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\plain\fs20 Laufzeit: Die SPUV wird f\'FCr die vereinbarte Vertragslaufzeit geschlossen (1,3, 5 oder 10 Jahre). Sie verl\'E4ngert sich automatisch um weitere 12 Monate, wenn sie nicht mit einer Frist von 3 Monaten zum Vertragsende gek\'FCndigt wird.\par
\pard\li1989\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\ls83\ilvl0{\listtext\fs20 4)\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\plain\fs20 Verg\'FCtung: F\'FCr die getroffene Vereinbarung berechnet ICONAG dem Lizenznehmer die entsprechend der Laufzeit vereinbarte Verg\'FCtung. Die Berechnung der Verg\'FCtung erfolgt auf Basis der jeweils aktuell g\'FCltigen Preisliste. Die Verg\'FCtung f\'FCr SPUV wird erstmals ab Beginn des Folgemonats bis zum Ende des laufenden Kalenderjahres berechnet. In den Folgejahren wird die Verg\'FCtung jeweils zu Beginn des Kalenderjahres f\'FCr volle 12 Monate im Voraus berechnet. Die nachtr\'E4glich erworbenen Erweiterungen der Erstlizenzen (wie z.B. Datenpunktupgrade, zus\'E4tzliche Funktionsmodule und native Schnittstellen von ICONAG), werden automatisch Bestandteil dieser SPUV. Die Nachberechnung der Verg\'FCtung erfolgt erstmalig f\'FCr die Zeit ab Auslieferung der jeweiligen Erweiterung von Beginn des Folgemonats bis zum Jahresende. Ab dem Folgejahr wird die SPUV f\'FCr Erstlizenzen und Erweiterungen zu Beginn des Kalenderjahres f\'FCr volle 12 Monate im Voraus berechnet. Lizenznehmer ohne laufende SPUV k\'F6nnen nachtr\'E4glich eine SPUV abschlie\'DFen. Dadurch wird zus\'E4tzlich ein Nachberechnungszuschlag in H\'F6he von 50% der j\'E4hrlichen SPUV-Verg\'FCtung f\'E4llig. Die Nachberechnung erfolgt ab dem nachtr\'E4glichen Abschluss der SPUV f\'FCr maximal 4 Jahre r\'FCckwirkend.\par
\pard\li1989\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\ls83\ilvl0{\listtext\fs20 5)\tab}\li2421\fi-360\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\vertalc\plain\fs20 Preisgleitklausel: F\'FCr diesen Laufzeitvertrag gilt eine Preisgleitklausel. Die Preisanpassung erfolgt kalenderj\'E4hrlich jeweils zum 1. Januar in H\'F6he der Preisentwicklung der Erzeugerpreise f\'FCr Dienstleistungen in Deutschland. Grundlage der Preisanpassung ist der Prozentsatz, der vom Statistischen Bundesamt f\'FCr das 3. Quartal des Vorjahres festgestellt wurde.\par
\pard\li1989\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\'A0\par
\li1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\b Kalkulationsgrundlage:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Listenpreis Lizenzen:\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 -XXXX,00 \u8364 ?\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20\par
\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 davon 21,00% pro Jahr\par
\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\plain\fs20 Laufzeit 1 Jahr\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\f0\fs20\b 1 Jahr\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 04.03.0020\tab\f0\b BACnet Tools - Softwarepflege- und Updatevereinbarung (Laufzeit 3 Jahre)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie zuvor, jedoch\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 -XXXX,00 \u8364 ?\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 18,00% pro Jahr\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 3 Jahre\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 Jahr\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 04.03.0030\tab\f0\b BACnet Tools - Softwarepflege- und Updatevereinbarung (Laufzeit 5 Jahre)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie zuvor, jedoch\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 -XXXX,00 \u8364 ?\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 15,00% pro Jahr\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 5 Jahre\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 Jahr\tab ......................\tab ..............................\par
\pard\plain\s8\li1701\fi-1701\ri1701\sb0\sa113\ql\vertalt\keepn\keep\f0\fs20\b0 04.03.0040\tab\f0\b BACnet Tools - Softwarepflege- und Updatevereinbarung (Laufzeit 10 Jahre)\par
\pard\plain\s0\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Wie zuvor, jedoch\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\b Kalkulationsgrundlage:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Listenpreis Lizenzen:\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 -XXXX,00 \u8364 ?\par
\pard\plain\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20\par
\pard\li1701\ri1701\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 davon 12,00% pro Jahr\par
\pard\li1701\ri1701\sa113\tx2421\tx3141\tx3861\tx4581\tx5301\tx6021\tx6741\tx7461\keepn\keep\plain\fs20 Laufzeit 10 Jahre\par
\pard\plain\s8\li1701\fi0\ri0\sb170\sa454\tqr\tx8164\tqr\tx10148\ql\vertalt\keep\f0\fs20\b 1 Jahr\tab ......................\tab ..............................\par
\pard\tblstart1{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 04.03\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Support und Softwarepflege\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trbrdrt\brdrs\brdrw15\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b Summe 04\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\ql\f0\fs20\b BACnet Tools\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb170\sa170\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\sect}\sectd\ltrsect\sbkpage\marglsxn1134\margrsxn567\margtsxn1134\margbsxn1134\headery1134\footery1134\sectdefaultcl{{\header{\pard\plain\s0\sa113\wpparflg32\plain\f0\fs20\b ICONAG-Leittechnik GmbH\par
\tx1701\wpparflg32\plain\f0\fs20 Projekt:\tab  \par
\tx1701\wpparflg32\plain\f0\fs20 LV-Bezeichnung:\tab B-CON Management- und Bedieneinrichtung\par
\pard\brdrt\brdrs\brdrw15\brdrb\brdrs\brdrw15\sb113\sa113\sl288\slmult1\tx1701\tqr\tx10148\vertalc\plain\fs20 OZ\tab Zusammenstellung (Ebene 3)\tab Summe EUR\par
\pard\plain\par
}}
{\footer{\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth2\clwWidth2500\clvertalt\cellx5086\clftsWidth2\clwWidth2500\clvertalt\cellx10172\pard\intbl\plain\s36\li0\fi0\ri0\sb0\sa0\ql\f2\fs18 LV-Datum: \cell\pard\intbl\plain\s37\li0\fi0\ri0\sb0\sa0\qr\f2\fs18 Seite {\field{\*\fldinst{PAGE}}{\*\fldrslt{217}}}\cell\row}\tblend1}}
\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 03.03.01\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Vorbereitung\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 03.03.02\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 BACnet-Netzwerkanalyse vor Ort\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 03.03.03\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Aufbereitung Ergebnisse und Ableitungen\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 03.03.04\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Abschluss\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Summe 03.03\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b BACnet-Netzwerkanalyse\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\sect}\sectd\ltrsect\sbkpage\marglsxn1134\margrsxn567\margtsxn1134\margbsxn1134\headery1134\footery1134\sectdefaultcl{{\header{\pard\plain\s0\sa113\wpparflg32\plain\f0\fs20\b ICONAG-Leittechnik GmbH\par
\tx1701\wpparflg32\plain\f0\fs20 Projekt:\tab  \par
\tx1701\wpparflg32\plain\f0\fs20 LV-Bezeichnung:\tab B-CON Management- und Bedieneinrichtung\par
\pard\brdrt\brdrs\brdrw15\brdrb\brdrs\brdrw15\sb113\sa113\sl288\slmult1\tx1701\tqr\tx10148\vertalc\plain\fs20 OZ\tab Zusammenstellung (Ebene 2)\tab Summe EUR\par
\pard\plain\par
}}
{\footer{\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth2\clwWidth2500\clvertalt\cellx5086\clftsWidth2\clwWidth2500\clvertalt\cellx10172\pard\intbl\plain\s36\li0\fi0\ri0\sb0\sa0\ql\f2\fs18 LV-Datum: \cell\pard\intbl\plain\s37\li0\fi0\ri0\sb0\sa0\qr\f2\fs18 Seite {\field{\*\fldinst{PAGE}}{\*\fldrslt{217}}}\cell\row}\tblend1}}
\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.01\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Creative Studio\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.02\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projekt-Runtimelizenzen f\'FCr OPC-DA, Modbus und KNX\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.03\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projekt-Runtimelizenzen f\'FCr BACnet\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.04\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Redundanz-Lizenzen f\'FCr OPC-DA, Modbus und KNX\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.05\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Redundanz-Lizenzen f\'FCr BACnet\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.06\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektlizenzen zum Benutzerzugriff\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.07\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektlizenzen f\'FCr erweiterte Funktionsmodule zum technischen Geb\'E4udemanagement\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.08\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektlizenzen zum Energie-Management\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 01.09\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 OPC-Server\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Summe 01\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Software\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\pard\plain\s0\par
\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.01\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Pflichtenheft\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.02\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Projektmanagement\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.03\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Grundkonfiguration Management- und  Bedieneinrichtung\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.04\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektierung X2B-CON-Treiber\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.05\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektierung OPC-Server\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.06\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektierung Datenpunktkonfiguration\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.07\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektierung Managementfunktionen\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.08\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektierung EnMS\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.09\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektierung Anlagenbilder\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.10\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 B-CON Projektierung Anlagenbilder nach Anlagentyp\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.11\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 BACnet-Projektierung nach VDI 3814\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.12\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Projektierung (Pauschal)\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.13\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Inbetriebnahme und Funktionstest\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.14\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Wartung und Softwarepflege\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.15\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Testaufbau BACnet-Kommunikation BACnet-MBE und BACnet-AS\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.16\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Schulung\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 02.17\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Automationsebene\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Summe 02\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Dienstleistung\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\pard\plain\s0\par
\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 03.01\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Standardisierung 2024\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 03.02\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Ausf\'FChrungsplanung BACnet-Konfiguration\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 03.03\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 BACnet-Netzwerkanalyse\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Summe 03\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Beratung / Planungsunterst\'FCtzung\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\pard\plain\s0\par
\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 04.01\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Software\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 04.02\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Dienstleistungen\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 04.03\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\ql\f0\fs20 Support und Softwarepflege\cell\pard\intbl\plain\s11\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clbrdrb\brdrs\brdrw15\clbrdrt\brdrs\brdrw15\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Summe 04\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b BACnet Tools\cell\pard\intbl\plain\s10\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\sect}\sectd\ltrsect\sbkpage\marglsxn1134\margrsxn567\margtsxn1134\margbsxn1134\headery1134\footery1134\sectdefaultcl{{\header{\pard\plain\s0\sa113\wpparflg32\plain\f0\fs20\b ICONAG-Leittechnik GmbH\par
\tx1701\wpparflg32\plain\f0\fs20 Projekt:\tab  \par
\tx1701\wpparflg32\plain\f0\fs20 LV-Bezeichnung:\tab B-CON Management- und Bedieneinrichtung\par
\pard\brdrt\brdrs\brdrw15\brdrb\brdrs\brdrw15\sb113\sa113\sl288\slmult1\tx1701\tqr\tx10148\vertalc\plain\fs20 OZ\tab Zusammenstellung\tab Summe EUR\par
\pard\plain\par
}}
{\footer{\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth2\clwWidth2500\clvertalt\cellx5086\clftsWidth2\clwWidth2500\clvertalt\cellx10172\pard\intbl\plain\s36\li0\fi0\ri0\sb0\sa0\ql\f2\fs18 LV-Datum: \cell\pard\intbl\plain\s37\li0\fi0\ri0\sb0\sa0\qr\f2\fs18 Seite {\field{\*\fldinst{PAGE}}{\*\fldrslt{217}}}\cell\row}\tblend1}}
\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b 01\cell\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Software\cell\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b 02\cell\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Dienstleistung\cell\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b 03\cell\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b Beratung / Planungsunterst\'FCtzung\cell\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b 04\cell\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\ql\f0\fs20\b BACnet Tools\cell\pard\intbl\plain\s9\li0\fi0\ri0\sb113\sa113\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1\pard\plain\brdrt\brdrs\brdrw15\s0\par
\pard\tblstart1{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb0\sa737\ql\f0\fs20\b Summe Zusammenstellung:\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb0\sa0\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb0\sa227\ql\f0\fs20\b Summe netto:\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb0\sa0\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb0\sa227\ql\f0\fs20\b zzgl. 19% MwSt:\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb0\sa0\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}{\trowd\trleft0\trftsWidth2\trwWidth5000\clftsWidth3\clwWidth1702\clvertalt\cellx1702\clftsWidth3\clwWidth6236\clvertalt\cellx7938\clftsWidth3\clwWidth2268\clvertalt\cellx10206\pard\intbl\li0\fi0\ri0\sb0\sa0\ql\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb0\sa227\ql\f0\fs20\b Summe inkl. MwSt:\cell\pard\intbl\plain\s8\li0\fi0\ri0\sb0\sa0\tqr\tx2211\ql\f0\fs20\b\tab ..............................\cell\row}\tblend1}}